Cargando…
Retinal nerve fibre layer thickness measurements in childhood glaucoma: the role of scanning laser polarimetry and optical coherence tomography
PURPOSE: A central diagnostic tool in adult glaucoma is the peripapillary retinal nerve fibre layer (pRNFL) thickness. It can be assessed by scanning laser polarimetry (SLP) or optical coherence tomography (OCT). However, studies investigating the relevance of pRNFL measurements in children are rare...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8589798/ https://www.ncbi.nlm.nih.gov/pubmed/34173881 http://dx.doi.org/10.1007/s00417-021-05276-z |
_version_ | 1784598810127761408 |
---|---|
author | Lever, Mael Halfwassen, Christian Unterlauft, Jan Darius Bechrakis, Nikolaos E. Manthey, Anke Böhm, Michael R. R. |
author_facet | Lever, Mael Halfwassen, Christian Unterlauft, Jan Darius Bechrakis, Nikolaos E. Manthey, Anke Böhm, Michael R. R. |
author_sort | Lever, Mael |
collection | PubMed |
description | PURPOSE: A central diagnostic tool in adult glaucoma is the peripapillary retinal nerve fibre layer (pRNFL) thickness. It can be assessed by scanning laser polarimetry (SLP) or optical coherence tomography (OCT). However, studies investigating the relevance of pRNFL measurements in children are rare. This study aims to compare the glaucoma diagnosing ability of SLP and OCT pRNFL thickness measurements in a paediatric population. METHODS: This retrospective study included 105 children (glaucoma: 22 (21.0%); healthy glaucoma suspects: 83 (79.0%)) aged 4–18 years, examined with SLP (GDxPro/ECC, Carl Zeiss Meditec) and spectral-domain OCT (SPECTRALIS®, Heidelberg Engineering). The thickness of pRNFL sectors was compared between diseased and healthy participants. Areas under the receiver-operating characteristic curves (AUC) and logistic regression results were used to compare the glaucoma discriminative capacity between SLP and OCT measurements. RESULTS: Using OCT, pRNFL thickness was decreased in the superior, nasal, and inferior quadrants of glaucoma patients compared to healthy controls (P < 0.001, each). With SLP, such a difference was only observed in the inferior quadrant (P = 0.011). A correlation between glaucoma diagnosis and OCT-measured pRNFL thickness was found in all quadrants (P < 0.001) other than the temporal. With SLP, a correlation was found for the total average thickness (P = 0.037) and inferior quadrant (P = 0.0019). Finally, the AUCs of OCT measurements were markedly higher than those of SLP (e.g., inferior quadrant: OCT 0.83, SLP 0.68). CONCLUSION: pRNFL thickness measurements using both OCT and SLP, correlate notably with the presence of glaucoma. In general, the diagnostic performance of pRNFL thickness measurements seems higher for OCT than for SLP. Thus, pRNFL thickness measurements could provide important information, complementing conventional clinical and functional parameters in the diagnostic process of paediatric glaucoma. [Image: see text] |
format | Online Article Text |
id | pubmed-8589798 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-85897982021-11-15 Retinal nerve fibre layer thickness measurements in childhood glaucoma: the role of scanning laser polarimetry and optical coherence tomography Lever, Mael Halfwassen, Christian Unterlauft, Jan Darius Bechrakis, Nikolaos E. Manthey, Anke Böhm, Michael R. R. Graefes Arch Clin Exp Ophthalmol Pediatrics PURPOSE: A central diagnostic tool in adult glaucoma is the peripapillary retinal nerve fibre layer (pRNFL) thickness. It can be assessed by scanning laser polarimetry (SLP) or optical coherence tomography (OCT). However, studies investigating the relevance of pRNFL measurements in children are rare. This study aims to compare the glaucoma diagnosing ability of SLP and OCT pRNFL thickness measurements in a paediatric population. METHODS: This retrospective study included 105 children (glaucoma: 22 (21.0%); healthy glaucoma suspects: 83 (79.0%)) aged 4–18 years, examined with SLP (GDxPro/ECC, Carl Zeiss Meditec) and spectral-domain OCT (SPECTRALIS®, Heidelberg Engineering). The thickness of pRNFL sectors was compared between diseased and healthy participants. Areas under the receiver-operating characteristic curves (AUC) and logistic regression results were used to compare the glaucoma discriminative capacity between SLP and OCT measurements. RESULTS: Using OCT, pRNFL thickness was decreased in the superior, nasal, and inferior quadrants of glaucoma patients compared to healthy controls (P < 0.001, each). With SLP, such a difference was only observed in the inferior quadrant (P = 0.011). A correlation between glaucoma diagnosis and OCT-measured pRNFL thickness was found in all quadrants (P < 0.001) other than the temporal. With SLP, a correlation was found for the total average thickness (P = 0.037) and inferior quadrant (P = 0.0019). Finally, the AUCs of OCT measurements were markedly higher than those of SLP (e.g., inferior quadrant: OCT 0.83, SLP 0.68). CONCLUSION: pRNFL thickness measurements using both OCT and SLP, correlate notably with the presence of glaucoma. In general, the diagnostic performance of pRNFL thickness measurements seems higher for OCT than for SLP. Thus, pRNFL thickness measurements could provide important information, complementing conventional clinical and functional parameters in the diagnostic process of paediatric glaucoma. [Image: see text] Springer Berlin Heidelberg 2021-06-26 2021 /pmc/articles/PMC8589798/ /pubmed/34173881 http://dx.doi.org/10.1007/s00417-021-05276-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Pediatrics Lever, Mael Halfwassen, Christian Unterlauft, Jan Darius Bechrakis, Nikolaos E. Manthey, Anke Böhm, Michael R. R. Retinal nerve fibre layer thickness measurements in childhood glaucoma: the role of scanning laser polarimetry and optical coherence tomography |
title | Retinal nerve fibre layer thickness measurements in childhood glaucoma: the role of scanning laser polarimetry and optical coherence tomography |
title_full | Retinal nerve fibre layer thickness measurements in childhood glaucoma: the role of scanning laser polarimetry and optical coherence tomography |
title_fullStr | Retinal nerve fibre layer thickness measurements in childhood glaucoma: the role of scanning laser polarimetry and optical coherence tomography |
title_full_unstemmed | Retinal nerve fibre layer thickness measurements in childhood glaucoma: the role of scanning laser polarimetry and optical coherence tomography |
title_short | Retinal nerve fibre layer thickness measurements in childhood glaucoma: the role of scanning laser polarimetry and optical coherence tomography |
title_sort | retinal nerve fibre layer thickness measurements in childhood glaucoma: the role of scanning laser polarimetry and optical coherence tomography |
topic | Pediatrics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8589798/ https://www.ncbi.nlm.nih.gov/pubmed/34173881 http://dx.doi.org/10.1007/s00417-021-05276-z |
work_keys_str_mv | AT levermael retinalnervefibrelayerthicknessmeasurementsinchildhoodglaucomatheroleofscanninglaserpolarimetryandopticalcoherencetomography AT halfwassenchristian retinalnervefibrelayerthicknessmeasurementsinchildhoodglaucomatheroleofscanninglaserpolarimetryandopticalcoherencetomography AT unterlauftjandarius retinalnervefibrelayerthicknessmeasurementsinchildhoodglaucomatheroleofscanninglaserpolarimetryandopticalcoherencetomography AT bechrakisnikolaose retinalnervefibrelayerthicknessmeasurementsinchildhoodglaucomatheroleofscanninglaserpolarimetryandopticalcoherencetomography AT mantheyanke retinalnervefibrelayerthicknessmeasurementsinchildhoodglaucomatheroleofscanninglaserpolarimetryandopticalcoherencetomography AT bohmmichaelrr retinalnervefibrelayerthicknessmeasurementsinchildhoodglaucomatheroleofscanninglaserpolarimetryandopticalcoherencetomography |