Cargando…

Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease

INTRODUCTION: To assess inter-device agreement in optical coherence tomography-derived retinal thickness measurements in patients with known macular conditions between spectral-domain and swept-source optical coherence tomography (OCT). METHODS: Two hundred seventy-two subjects were included in the...

Descripción completa

Detalles Bibliográficos
Autores principales: Hanumunthadu, Daren, Keane, Pearse A., Balaskas, Konstantinos, Dubis, Adam M., Kalitzeos, Angelos, Michaelides, Michel, Patel, Praveen J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8589877/
https://www.ncbi.nlm.nih.gov/pubmed/34324166
http://dx.doi.org/10.1007/s40123-021-00377-8
_version_ 1784598827955650560
author Hanumunthadu, Daren
Keane, Pearse A.
Balaskas, Konstantinos
Dubis, Adam M.
Kalitzeos, Angelos
Michaelides, Michel
Patel, Praveen J.
author_facet Hanumunthadu, Daren
Keane, Pearse A.
Balaskas, Konstantinos
Dubis, Adam M.
Kalitzeos, Angelos
Michaelides, Michel
Patel, Praveen J.
author_sort Hanumunthadu, Daren
collection PubMed
description INTRODUCTION: To assess inter-device agreement in optical coherence tomography-derived retinal thickness measurements in patients with known macular conditions between spectral-domain and swept-source optical coherence tomography (OCT). METHODS: Two hundred seventy-two subjects were included in the study. They consisted of 91 male (33.5%) and 181 female (66.5%) subjects, and 132 left (48.5%) and 140 right (51.5%) eyes. Each subject underwent spectral-domain OCT (SD-OCT, Spectralis, Heidelberg Engineering; RTVue XR Avanti XR HD, Optovue) and swept-source OCT (SS-OCT; DRI-OCT-1, Atlantis, Topcon) in a single imaging session performed by the same clinical trial-certified technician. The comparison of retinal thickness reproducibility between devices was performed using Bland–Altman analyses and across the entire data set using the intraclass correlation coefficient (ICC). RESULTS: The ICC of the retinal thickness measurements (95% confidence interval) made using all three OCT instruments was 0.81 (0.77–0.84). The mean difference in mean retinal thickness between Spectralis SD-OCT and Topcon SS-OCT was 59.1 μm (95% limit of agreement [LoA] −21.7 to 139.8 μm). The mean difference in mean retinal thickness between Optovue SD-OCT and Topcon SS-OCT was 21.8 μm (95% LoA −34.7  to 78.3 μm). CONCLUSIONS: Retinal layer thickness measurements vary between SS-OCT and SD-OCT devices. We describe inter-device agreement in retinal thickness between SS-OCT and SD-OCT in patients with macular conditions. Clinicians should be aware of the differences in retinal thickness values when imaging patients using different OCT devices and should consider using the same OCT device model in order to monitor clinical change. TRIAL REGISTRATION: ClinicalTrials.gov Identifier (NCT02828215).
format Online
Article
Text
id pubmed-8589877
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Healthcare
record_format MEDLINE/PubMed
spelling pubmed-85898772021-11-23 Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease Hanumunthadu, Daren Keane, Pearse A. Balaskas, Konstantinos Dubis, Adam M. Kalitzeos, Angelos Michaelides, Michel Patel, Praveen J. Ophthalmol Ther Original Research INTRODUCTION: To assess inter-device agreement in optical coherence tomography-derived retinal thickness measurements in patients with known macular conditions between spectral-domain and swept-source optical coherence tomography (OCT). METHODS: Two hundred seventy-two subjects were included in the study. They consisted of 91 male (33.5%) and 181 female (66.5%) subjects, and 132 left (48.5%) and 140 right (51.5%) eyes. Each subject underwent spectral-domain OCT (SD-OCT, Spectralis, Heidelberg Engineering; RTVue XR Avanti XR HD, Optovue) and swept-source OCT (SS-OCT; DRI-OCT-1, Atlantis, Topcon) in a single imaging session performed by the same clinical trial-certified technician. The comparison of retinal thickness reproducibility between devices was performed using Bland–Altman analyses and across the entire data set using the intraclass correlation coefficient (ICC). RESULTS: The ICC of the retinal thickness measurements (95% confidence interval) made using all three OCT instruments was 0.81 (0.77–0.84). The mean difference in mean retinal thickness between Spectralis SD-OCT and Topcon SS-OCT was 59.1 μm (95% limit of agreement [LoA] −21.7 to 139.8 μm). The mean difference in mean retinal thickness between Optovue SD-OCT and Topcon SS-OCT was 21.8 μm (95% LoA −34.7  to 78.3 μm). CONCLUSIONS: Retinal layer thickness measurements vary between SS-OCT and SD-OCT devices. We describe inter-device agreement in retinal thickness between SS-OCT and SD-OCT in patients with macular conditions. Clinicians should be aware of the differences in retinal thickness values when imaging patients using different OCT devices and should consider using the same OCT device model in order to monitor clinical change. TRIAL REGISTRATION: ClinicalTrials.gov Identifier (NCT02828215). Springer Healthcare 2021-07-29 2021-12 /pmc/articles/PMC8589877/ /pubmed/34324166 http://dx.doi.org/10.1007/s40123-021-00377-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/Open Access This article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Original Research
Hanumunthadu, Daren
Keane, Pearse A.
Balaskas, Konstantinos
Dubis, Adam M.
Kalitzeos, Angelos
Michaelides, Michel
Patel, Praveen J.
Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease
title Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease
title_full Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease
title_fullStr Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease
title_full_unstemmed Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease
title_short Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease
title_sort agreement between spectral-domain and swept-source optical coherence tomography retinal thickness measurements in macular and retinal disease
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8589877/
https://www.ncbi.nlm.nih.gov/pubmed/34324166
http://dx.doi.org/10.1007/s40123-021-00377-8
work_keys_str_mv AT hanumunthadudaren agreementbetweenspectraldomainandsweptsourceopticalcoherencetomographyretinalthicknessmeasurementsinmacularandretinaldisease
AT keanepearsea agreementbetweenspectraldomainandsweptsourceopticalcoherencetomographyretinalthicknessmeasurementsinmacularandretinaldisease
AT balaskaskonstantinos agreementbetweenspectraldomainandsweptsourceopticalcoherencetomographyretinalthicknessmeasurementsinmacularandretinaldisease
AT dubisadamm agreementbetweenspectraldomainandsweptsourceopticalcoherencetomographyretinalthicknessmeasurementsinmacularandretinaldisease
AT kalitzeosangelos agreementbetweenspectraldomainandsweptsourceopticalcoherencetomographyretinalthicknessmeasurementsinmacularandretinaldisease
AT michaelidesmichel agreementbetweenspectraldomainandsweptsourceopticalcoherencetomographyretinalthicknessmeasurementsinmacularandretinaldisease
AT patelpraveenj agreementbetweenspectraldomainandsweptsourceopticalcoherencetomographyretinalthicknessmeasurementsinmacularandretinaldisease