Cargando…

Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study

OBJECTIVES: The least amount of contrast medium (CM) should be used under the premise of adequate diagnosis. The purpose of this study is to evaluate the feasibility of utilizing ultra-low-dose (224 mgI/kg) CM for pancreatic artery depiction using the combination of advanced virtual monoenergetic im...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Juan, Wang, Yu-hong, Zheng, Fu-ling, Chen, Xin-yue, Lin, Yun, Zhu, Cai-rong, Wu, Yi-fan, Xu, Qiang, Jin, Zheng-yu, Xue, Hua-dan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8589906/
https://www.ncbi.nlm.nih.gov/pubmed/34767101
http://dx.doi.org/10.1186/s13244-021-01079-2
_version_ 1784598832657465344
author Li, Juan
Wang, Yu-hong
Zheng, Fu-ling
Chen, Xin-yue
Lin, Yun
Zhu, Cai-rong
Wu, Yi-fan
Xu, Qiang
Jin, Zheng-yu
Xue, Hua-dan
author_facet Li, Juan
Wang, Yu-hong
Zheng, Fu-ling
Chen, Xin-yue
Lin, Yun
Zhu, Cai-rong
Wu, Yi-fan
Xu, Qiang
Jin, Zheng-yu
Xue, Hua-dan
author_sort Li, Juan
collection PubMed
description OBJECTIVES: The least amount of contrast medium (CM) should be used under the premise of adequate diagnosis. The purpose of this study is to evaluate the feasibility of utilizing ultra-low-dose (224 mgI/kg) CM for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging (VMI+) and high-concentration (400 mgI/mL) CM. MATERIALS AND METHODS: 41 patients who underwent both normal dose CM (ND-CM, 320 mgI/kg) and low dose CM (LD-CM, 224 mgI/kg) thoracoabdominal enhanced CT for tumor follow-up were prospectively included. The VMI+ at the energy level of 40-kev for LD-CM images was reconstructed. CT attenuation, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs) of the abdominal artery, celiac artery, and superior mesenteric artery (SMA) and qualitative scores of pancreatic arteries depiction were recorded and compared among the three groups (ND-CM, LD-CM, and VMI+ LD-CM images). ANOVA and Friedman tests were used for statistical analysis. RESULTS: All quantitative and qualitative parameters on LD-CM images were lower than that on ND-CM images (all p < 0.01). There were no significant differences of all arteries’ qualitative scores between ND-CM and VMI+ LD-CM images (all p > 0.05). VMI+ LD-CM images had the highest mean CT and CNR values of all arteries (all p < 0.0001). The CM volume was 52.6 ± 9.4 mL for the ND-CM group and 37.0 ± 6.7 mL for the LD-CM group. CONCLUSION: Ultra-low-dose CM (224 mgI/kg) was feasible for depicting pancreatic arteries. Inferior angiographic image quality could be successfully compensated by VMI+ and high-concentration CM.
format Online
Article
Text
id pubmed-8589906
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-85899062021-11-23 Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study Li, Juan Wang, Yu-hong Zheng, Fu-ling Chen, Xin-yue Lin, Yun Zhu, Cai-rong Wu, Yi-fan Xu, Qiang Jin, Zheng-yu Xue, Hua-dan Insights Imaging Original Article OBJECTIVES: The least amount of contrast medium (CM) should be used under the premise of adequate diagnosis. The purpose of this study is to evaluate the feasibility of utilizing ultra-low-dose (224 mgI/kg) CM for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging (VMI+) and high-concentration (400 mgI/mL) CM. MATERIALS AND METHODS: 41 patients who underwent both normal dose CM (ND-CM, 320 mgI/kg) and low dose CM (LD-CM, 224 mgI/kg) thoracoabdominal enhanced CT for tumor follow-up were prospectively included. The VMI+ at the energy level of 40-kev for LD-CM images was reconstructed. CT attenuation, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs) of the abdominal artery, celiac artery, and superior mesenteric artery (SMA) and qualitative scores of pancreatic arteries depiction were recorded and compared among the three groups (ND-CM, LD-CM, and VMI+ LD-CM images). ANOVA and Friedman tests were used for statistical analysis. RESULTS: All quantitative and qualitative parameters on LD-CM images were lower than that on ND-CM images (all p < 0.01). There were no significant differences of all arteries’ qualitative scores between ND-CM and VMI+ LD-CM images (all p > 0.05). VMI+ LD-CM images had the highest mean CT and CNR values of all arteries (all p < 0.0001). The CM volume was 52.6 ± 9.4 mL for the ND-CM group and 37.0 ± 6.7 mL for the LD-CM group. CONCLUSION: Ultra-low-dose CM (224 mgI/kg) was feasible for depicting pancreatic arteries. Inferior angiographic image quality could be successfully compensated by VMI+ and high-concentration CM. Springer International Publishing 2021-11-12 /pmc/articles/PMC8589906/ /pubmed/34767101 http://dx.doi.org/10.1186/s13244-021-01079-2 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Li, Juan
Wang, Yu-hong
Zheng, Fu-ling
Chen, Xin-yue
Lin, Yun
Zhu, Cai-rong
Wu, Yi-fan
Xu, Qiang
Jin, Zheng-yu
Xue, Hua-dan
Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
title Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
title_full Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
title_fullStr Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
title_full_unstemmed Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
title_short Feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
title_sort feasibility of utilizing ultra-low-dose contrast medium for pancreatic artery depiction using the combination of advanced virtual monoenergetic imaging and high-concentration contrast medium: an intra-patient study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8589906/
https://www.ncbi.nlm.nih.gov/pubmed/34767101
http://dx.doi.org/10.1186/s13244-021-01079-2
work_keys_str_mv AT lijuan feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT wangyuhong feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT zhengfuling feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT chenxinyue feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT linyun feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT zhucairong feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT wuyifan feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT xuqiang feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT jinzhengyu feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy
AT xuehuadan feasibilityofutilizingultralowdosecontrastmediumforpancreaticarterydepictionusingthecombinationofadvancedvirtualmonoenergeticimagingandhighconcentrationcontrastmediumanintrapatientstudy