Cargando…

EANM dosimetry committee series on standard operational procedures: a unified methodology for (99m)Tc-MAA pre- and (90)Y peri-therapy dosimetry in liver radioembolization with (90)Y microspheres

The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in (90)Y microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy depositi...

Descripción completa

Detalles Bibliográficos
Autores principales: Chiesa, Carlo, Sjogreen-Gleisner, Katarina, Walrand, Stephan, Strigari, Lidia, Flux, Glenn, Gear, Jonathan, Stokke, Caroline, Gabina, Pablo Minguez, Bernhardt, Peter, Konijnenberg, Mark
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8589932/
https://www.ncbi.nlm.nih.gov/pubmed/34767102
http://dx.doi.org/10.1186/s40658-021-00394-3
_version_ 1784598837179973632
author Chiesa, Carlo
Sjogreen-Gleisner, Katarina
Walrand, Stephan
Strigari, Lidia
Flux, Glenn
Gear, Jonathan
Stokke, Caroline
Gabina, Pablo Minguez
Bernhardt, Peter
Konijnenberg, Mark
author_facet Chiesa, Carlo
Sjogreen-Gleisner, Katarina
Walrand, Stephan
Strigari, Lidia
Flux, Glenn
Gear, Jonathan
Stokke, Caroline
Gabina, Pablo Minguez
Bernhardt, Peter
Konijnenberg, Mark
author_sort Chiesa, Carlo
collection PubMed
description The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in (90)Y microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient–relative calibration method for activity quantification.The identity of (99m)Tc albumin macro-aggregates (MAA) and (90)Y microsphere biodistribution is also assumed. The large observed discrepancies in some patients between (99m)Tc-MAA predictions and actual (90)Y microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments. Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected (99m)Tc-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and (90)Y TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected (99m)Tc-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative (90)Y bremsstrahlung SPECT can be used if dedicated correction methods are available. The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40658-021-00394-3.
format Online
Article
Text
id pubmed-8589932
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-85899322021-11-23 EANM dosimetry committee series on standard operational procedures: a unified methodology for (99m)Tc-MAA pre- and (90)Y peri-therapy dosimetry in liver radioembolization with (90)Y microspheres Chiesa, Carlo Sjogreen-Gleisner, Katarina Walrand, Stephan Strigari, Lidia Flux, Glenn Gear, Jonathan Stokke, Caroline Gabina, Pablo Minguez Bernhardt, Peter Konijnenberg, Mark EJNMMI Phys Guideline The aim of this standard operational procedure is to standardize the methodology employed for the evaluation of pre- and post-treatment absorbed dose calculations in (90)Y microsphere liver radioembolization. Basic assumptions include the permanent trapping of microspheres, the local energy deposition method for voxel dosimetry, and the patient–relative calibration method for activity quantification.The identity of (99m)Tc albumin macro-aggregates (MAA) and (90)Y microsphere biodistribution is also assumed. The large observed discrepancies in some patients between (99m)Tc-MAA predictions and actual (90)Y microsphere distributions for lesions is discussed. Absorbed dose predictions to whole non-tumoural liver are considered more reliable and the basic predictors of toxicity. Treatment planning based on mean absorbed dose delivered to the whole non-tumoural liver is advised, except in super-selective treatments. Given the potential mismatch between MAA simulation and actual therapy, absorbed doses should be calculated both pre- and post-therapy. Distinct evaluation between target tumours and non-tumoural tissue, including lungs in cases of lung shunt, are vital for proper optimization of therapy. Dosimetry should be performed first according to a mean absorbed dose approach, with an optional, but important, voxel level evaluation. Fully corrected (99m)Tc-MAA Single Photon Emission Computed Tomography (SPECT)/computed tomography (CT) and (90)Y TOF PET/CT are regarded as optimal acquisition methodologies, but, for institutes where SPECT/CT is not available, non-attenuation corrected (99m)Tc-MAA SPECT may be used. This offers better planning quality than non dosimetric methods such as Body Surface Area (BSA) or mono-compartmental dosimetry. Quantitative (90)Y bremsstrahlung SPECT can be used if dedicated correction methods are available. The proposed methodology is feasible with standard camera software and a spreadsheet. Available commercial or free software can help facilitate the process and improve calculation time. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40658-021-00394-3. Springer International Publishing 2021-11-12 /pmc/articles/PMC8589932/ /pubmed/34767102 http://dx.doi.org/10.1186/s40658-021-00394-3 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Guideline
Chiesa, Carlo
Sjogreen-Gleisner, Katarina
Walrand, Stephan
Strigari, Lidia
Flux, Glenn
Gear, Jonathan
Stokke, Caroline
Gabina, Pablo Minguez
Bernhardt, Peter
Konijnenberg, Mark
EANM dosimetry committee series on standard operational procedures: a unified methodology for (99m)Tc-MAA pre- and (90)Y peri-therapy dosimetry in liver radioembolization with (90)Y microspheres
title EANM dosimetry committee series on standard operational procedures: a unified methodology for (99m)Tc-MAA pre- and (90)Y peri-therapy dosimetry in liver radioembolization with (90)Y microspheres
title_full EANM dosimetry committee series on standard operational procedures: a unified methodology for (99m)Tc-MAA pre- and (90)Y peri-therapy dosimetry in liver radioembolization with (90)Y microspheres
title_fullStr EANM dosimetry committee series on standard operational procedures: a unified methodology for (99m)Tc-MAA pre- and (90)Y peri-therapy dosimetry in liver radioembolization with (90)Y microspheres
title_full_unstemmed EANM dosimetry committee series on standard operational procedures: a unified methodology for (99m)Tc-MAA pre- and (90)Y peri-therapy dosimetry in liver radioembolization with (90)Y microspheres
title_short EANM dosimetry committee series on standard operational procedures: a unified methodology for (99m)Tc-MAA pre- and (90)Y peri-therapy dosimetry in liver radioembolization with (90)Y microspheres
title_sort eanm dosimetry committee series on standard operational procedures: a unified methodology for (99m)tc-maa pre- and (90)y peri-therapy dosimetry in liver radioembolization with (90)y microspheres
topic Guideline
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8589932/
https://www.ncbi.nlm.nih.gov/pubmed/34767102
http://dx.doi.org/10.1186/s40658-021-00394-3
work_keys_str_mv AT chiesacarlo eanmdosimetrycommitteeseriesonstandardoperationalproceduresaunifiedmethodologyfor99mtcmaapreand90yperitherapydosimetryinliverradioembolizationwith90ymicrospheres
AT sjogreengleisnerkatarina eanmdosimetrycommitteeseriesonstandardoperationalproceduresaunifiedmethodologyfor99mtcmaapreand90yperitherapydosimetryinliverradioembolizationwith90ymicrospheres
AT walrandstephan eanmdosimetrycommitteeseriesonstandardoperationalproceduresaunifiedmethodologyfor99mtcmaapreand90yperitherapydosimetryinliverradioembolizationwith90ymicrospheres
AT strigarilidia eanmdosimetrycommitteeseriesonstandardoperationalproceduresaunifiedmethodologyfor99mtcmaapreand90yperitherapydosimetryinliverradioembolizationwith90ymicrospheres
AT fluxglenn eanmdosimetrycommitteeseriesonstandardoperationalproceduresaunifiedmethodologyfor99mtcmaapreand90yperitherapydosimetryinliverradioembolizationwith90ymicrospheres
AT gearjonathan eanmdosimetrycommitteeseriesonstandardoperationalproceduresaunifiedmethodologyfor99mtcmaapreand90yperitherapydosimetryinliverradioembolizationwith90ymicrospheres
AT stokkecaroline eanmdosimetrycommitteeseriesonstandardoperationalproceduresaunifiedmethodologyfor99mtcmaapreand90yperitherapydosimetryinliverradioembolizationwith90ymicrospheres
AT gabinapablominguez eanmdosimetrycommitteeseriesonstandardoperationalproceduresaunifiedmethodologyfor99mtcmaapreand90yperitherapydosimetryinliverradioembolizationwith90ymicrospheres
AT bernhardtpeter eanmdosimetrycommitteeseriesonstandardoperationalproceduresaunifiedmethodologyfor99mtcmaapreand90yperitherapydosimetryinliverradioembolizationwith90ymicrospheres
AT konijnenbergmark eanmdosimetrycommitteeseriesonstandardoperationalproceduresaunifiedmethodologyfor99mtcmaapreand90yperitherapydosimetryinliverradioembolizationwith90ymicrospheres