A Smart Vitrector Equipped by a Fiber-Based OCT Sensor Mitigates Intentional Attempts at Creating Iatrogenic Retinal Breaks During Vitrectomy in Pigs

PURPOSE: The occurrence of iatrogenic retinal breaks (RB) in pars plana vitrectomy (PPV) is a complication that compromises the overall efficacy of the surgery. A subset of iatrogenic RB occurs when the retina (rather than the vitreous gel) is cut accidentally by the vitrector. We developed a smart...

Descripción completa

Detalles Bibliográficos
Autores principales: Abid, Alexandre, Duval, Renaud, Rezende, Flavio, Boutopoulos, Christos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8590174/
https://www.ncbi.nlm.nih.gov/pubmed/34767622
http://dx.doi.org/10.1167/tvst.10.13.19
_version_ 1784598899236798464
author Abid, Alexandre
Duval, Renaud
Rezende, Flavio
Boutopoulos, Christos
author_facet Abid, Alexandre
Duval, Renaud
Rezende, Flavio
Boutopoulos, Christos
author_sort Abid, Alexandre
collection PubMed
description PURPOSE: The occurrence of iatrogenic retinal breaks (RB) in pars plana vitrectomy (PPV) is a complication that compromises the overall efficacy of the surgery. A subset of iatrogenic RB occurs when the retina (rather than the vitreous gel) is cut accidentally by the vitrector. We developed a smart vitrector that can detect in real-time potential iatrogenic RB and activate promptly a PPV machine response to prevent them. METHODS: We fabricated the smart vitrectors by attaching a miniaturized fiber-based OCT sensor on commercial vitrectors (25G). The system's response time to an iatrogenic RB onset was measured and compared to the literature reported physiologically limited response time of the average surgeon. Two surgeons validated its ability to prevent simulated iatrogenic RB by performing PPV in pigs. Note that the system is meant to control the PPV machine and requires no visual or audio signal interpretation by the surgeons. RESULTS: We found that the response time of the system (28.9 ± 6.5 ms) is 11 times shorter compared to the literature reported physiologically limited reaction time of the average surgeon (P < 0.0001). Ex vivo validation (porcine eyes) showed that the system prevents 78.95% (15/19) (95% confidence interval [CI] 54.43–93.95) of intentional attempts at creating RB, whereas in vivo validation showed that the system, prevents 55.68% (30/54) (95% CI 41.40–69.08), and prevents or mitigates 70.37% (38/54) (95% CI 56.39–82.02) of such attempts. A subset of failures was classified as “early stop” (i.e., false positive), having a prevalence of 5.26% (1/19) in ex vivo tests and 24.07% (13/54) in in vivo tests. CONCLUSIONS: Our results indicate the smart vitrector can prevent iatrogenic RB by providing seamless intraoperative feedback to the PPV machine. Importantly, the use of the smart vitrector requires no modifications of the established PPV procedure. It can mitigate a significant proportion of iatrogenic RB and thus improve the overall efficacy of the surgery. TRANSLATIONAL RELEVANCE: Potential clinical adoption of the smart vitrector can reduce the incidence of iatrogenic RB in PPV and thus increase the therapeutic outcome of the surgery.
format Online
Article
Text
id pubmed-8590174
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-85901742021-11-24 A Smart Vitrector Equipped by a Fiber-Based OCT Sensor Mitigates Intentional Attempts at Creating Iatrogenic Retinal Breaks During Vitrectomy in Pigs Abid, Alexandre Duval, Renaud Rezende, Flavio Boutopoulos, Christos Transl Vis Sci Technol Article PURPOSE: The occurrence of iatrogenic retinal breaks (RB) in pars plana vitrectomy (PPV) is a complication that compromises the overall efficacy of the surgery. A subset of iatrogenic RB occurs when the retina (rather than the vitreous gel) is cut accidentally by the vitrector. We developed a smart vitrector that can detect in real-time potential iatrogenic RB and activate promptly a PPV machine response to prevent them. METHODS: We fabricated the smart vitrectors by attaching a miniaturized fiber-based OCT sensor on commercial vitrectors (25G). The system's response time to an iatrogenic RB onset was measured and compared to the literature reported physiologically limited response time of the average surgeon. Two surgeons validated its ability to prevent simulated iatrogenic RB by performing PPV in pigs. Note that the system is meant to control the PPV machine and requires no visual or audio signal interpretation by the surgeons. RESULTS: We found that the response time of the system (28.9 ± 6.5 ms) is 11 times shorter compared to the literature reported physiologically limited reaction time of the average surgeon (P < 0.0001). Ex vivo validation (porcine eyes) showed that the system prevents 78.95% (15/19) (95% confidence interval [CI] 54.43–93.95) of intentional attempts at creating RB, whereas in vivo validation showed that the system, prevents 55.68% (30/54) (95% CI 41.40–69.08), and prevents or mitigates 70.37% (38/54) (95% CI 56.39–82.02) of such attempts. A subset of failures was classified as “early stop” (i.e., false positive), having a prevalence of 5.26% (1/19) in ex vivo tests and 24.07% (13/54) in in vivo tests. CONCLUSIONS: Our results indicate the smart vitrector can prevent iatrogenic RB by providing seamless intraoperative feedback to the PPV machine. Importantly, the use of the smart vitrector requires no modifications of the established PPV procedure. It can mitigate a significant proportion of iatrogenic RB and thus improve the overall efficacy of the surgery. TRANSLATIONAL RELEVANCE: Potential clinical adoption of the smart vitrector can reduce the incidence of iatrogenic RB in PPV and thus increase the therapeutic outcome of the surgery. The Association for Research in Vision and Ophthalmology 2021-11-12 /pmc/articles/PMC8590174/ /pubmed/34767622 http://dx.doi.org/10.1167/tvst.10.13.19 Text en Copyright 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Article
Abid, Alexandre
Duval, Renaud
Rezende, Flavio
Boutopoulos, Christos
A Smart Vitrector Equipped by a Fiber-Based OCT Sensor Mitigates Intentional Attempts at Creating Iatrogenic Retinal Breaks During Vitrectomy in Pigs
title A Smart Vitrector Equipped by a Fiber-Based OCT Sensor Mitigates Intentional Attempts at Creating Iatrogenic Retinal Breaks During Vitrectomy in Pigs
title_full A Smart Vitrector Equipped by a Fiber-Based OCT Sensor Mitigates Intentional Attempts at Creating Iatrogenic Retinal Breaks During Vitrectomy in Pigs
title_fullStr A Smart Vitrector Equipped by a Fiber-Based OCT Sensor Mitigates Intentional Attempts at Creating Iatrogenic Retinal Breaks During Vitrectomy in Pigs
title_full_unstemmed A Smart Vitrector Equipped by a Fiber-Based OCT Sensor Mitigates Intentional Attempts at Creating Iatrogenic Retinal Breaks During Vitrectomy in Pigs
title_short A Smart Vitrector Equipped by a Fiber-Based OCT Sensor Mitigates Intentional Attempts at Creating Iatrogenic Retinal Breaks During Vitrectomy in Pigs
title_sort smart vitrector equipped by a fiber-based oct sensor mitigates intentional attempts at creating iatrogenic retinal breaks during vitrectomy in pigs
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8590174/
https://www.ncbi.nlm.nih.gov/pubmed/34767622
http://dx.doi.org/10.1167/tvst.10.13.19
work_keys_str_mv AT abidalexandre asmartvitrectorequippedbyafiberbasedoctsensormitigatesintentionalattemptsatcreatingiatrogenicretinalbreaksduringvitrectomyinpigs
AT duvalrenaud asmartvitrectorequippedbyafiberbasedoctsensormitigatesintentionalattemptsatcreatingiatrogenicretinalbreaksduringvitrectomyinpigs
AT rezendeflavio asmartvitrectorequippedbyafiberbasedoctsensormitigatesintentionalattemptsatcreatingiatrogenicretinalbreaksduringvitrectomyinpigs
AT boutopouloschristos asmartvitrectorequippedbyafiberbasedoctsensormitigatesintentionalattemptsatcreatingiatrogenicretinalbreaksduringvitrectomyinpigs
AT abidalexandre smartvitrectorequippedbyafiberbasedoctsensormitigatesintentionalattemptsatcreatingiatrogenicretinalbreaksduringvitrectomyinpigs
AT duvalrenaud smartvitrectorequippedbyafiberbasedoctsensormitigatesintentionalattemptsatcreatingiatrogenicretinalbreaksduringvitrectomyinpigs
AT rezendeflavio smartvitrectorequippedbyafiberbasedoctsensormitigatesintentionalattemptsatcreatingiatrogenicretinalbreaksduringvitrectomyinpigs
AT boutopouloschristos smartvitrectorequippedbyafiberbasedoctsensormitigatesintentionalattemptsatcreatingiatrogenicretinalbreaksduringvitrectomyinpigs