Cargando…

High-Accuracy Determination of Potassium and Selenium in Human Serum by Two-Step Isotope Dilution ICPMS

A high-accuracy measurement technique for determining potassium and selenium in human serum was developed by using two-step Isotope Dilution Inductively Coupled Plasma-Mass Spectrometry (ICPMS) in this research. A more accessible method of the quadrupole ICPMS was employed in this research to achiev...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Jian, Chi, Lixia, Li, Shengmin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8590592/
https://www.ncbi.nlm.nih.gov/pubmed/34782852
http://dx.doi.org/10.1155/2021/5533631
_version_ 1784599009335181312
author Yang, Jian
Chi, Lixia
Li, Shengmin
author_facet Yang, Jian
Chi, Lixia
Li, Shengmin
author_sort Yang, Jian
collection PubMed
description A high-accuracy measurement technique for determining potassium and selenium in human serum was developed by using two-step Isotope Dilution Inductively Coupled Plasma-Mass Spectrometry (ICPMS) in this research. A more accessible method of the quadrupole ICPMS was employed in this research to achieve an equally high accuracy which had been achieved by a much more expensive method, namely, high-resolution sector field ICPMS (SF-ICPMS), with a comparatively easy and simple operation. In addition, we have evaluated the uncertainty of this method. The results showed that the determination limits of potassium and selenium in serum were 0.8 mg/kg and 2.7 μg/kg, respectively, and the precision for both measurements was lower than 0.2% and 0.7%. The measurement, when employed to measure potassium and selenium in standard materials NIST956D, NIST909C, and GBW09152, had caused a maximum deviation of less than 0.9%, within the stated uncertainty range of standard materials. The RELA international inter-laboratory comparisons of potassium in serum in 2018 conducted by our laboratory also yielded a satisfactory result.
format Online
Article
Text
id pubmed-8590592
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-85905922021-11-14 High-Accuracy Determination of Potassium and Selenium in Human Serum by Two-Step Isotope Dilution ICPMS Yang, Jian Chi, Lixia Li, Shengmin J Anal Methods Chem Research Article A high-accuracy measurement technique for determining potassium and selenium in human serum was developed by using two-step Isotope Dilution Inductively Coupled Plasma-Mass Spectrometry (ICPMS) in this research. A more accessible method of the quadrupole ICPMS was employed in this research to achieve an equally high accuracy which had been achieved by a much more expensive method, namely, high-resolution sector field ICPMS (SF-ICPMS), with a comparatively easy and simple operation. In addition, we have evaluated the uncertainty of this method. The results showed that the determination limits of potassium and selenium in serum were 0.8 mg/kg and 2.7 μg/kg, respectively, and the precision for both measurements was lower than 0.2% and 0.7%. The measurement, when employed to measure potassium and selenium in standard materials NIST956D, NIST909C, and GBW09152, had caused a maximum deviation of less than 0.9%, within the stated uncertainty range of standard materials. The RELA international inter-laboratory comparisons of potassium in serum in 2018 conducted by our laboratory also yielded a satisfactory result. Hindawi 2021-11-06 /pmc/articles/PMC8590592/ /pubmed/34782852 http://dx.doi.org/10.1155/2021/5533631 Text en Copyright © 2021 Jian Yang et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Yang, Jian
Chi, Lixia
Li, Shengmin
High-Accuracy Determination of Potassium and Selenium in Human Serum by Two-Step Isotope Dilution ICPMS
title High-Accuracy Determination of Potassium and Selenium in Human Serum by Two-Step Isotope Dilution ICPMS
title_full High-Accuracy Determination of Potassium and Selenium in Human Serum by Two-Step Isotope Dilution ICPMS
title_fullStr High-Accuracy Determination of Potassium and Selenium in Human Serum by Two-Step Isotope Dilution ICPMS
title_full_unstemmed High-Accuracy Determination of Potassium and Selenium in Human Serum by Two-Step Isotope Dilution ICPMS
title_short High-Accuracy Determination of Potassium and Selenium in Human Serum by Two-Step Isotope Dilution ICPMS
title_sort high-accuracy determination of potassium and selenium in human serum by two-step isotope dilution icpms
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8590592/
https://www.ncbi.nlm.nih.gov/pubmed/34782852
http://dx.doi.org/10.1155/2021/5533631
work_keys_str_mv AT yangjian highaccuracydeterminationofpotassiumandseleniuminhumanserumbytwostepisotopedilutionicpms
AT chilixia highaccuracydeterminationofpotassiumandseleniuminhumanserumbytwostepisotopedilutionicpms
AT lishengmin highaccuracydeterminationofpotassiumandseleniuminhumanserumbytwostepisotopedilutionicpms