Cargando…

Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion

OBJECTIVE: Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result i...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Hyun Jun, Park, Eun Soo, Lee, Sang Ho, Park, Chan Hong, Chung, Seok Won
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Neurosurgical Society 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8590905/
https://www.ncbi.nlm.nih.gov/pubmed/34420290
http://dx.doi.org/10.3340/jkns.2020.0338
_version_ 1784599088871768064
author Kim, Hyun Jun
Park, Eun Soo
Lee, Sang Ho
Park, Chan Hong
Chung, Seok Won
author_facet Kim, Hyun Jun
Park, Eun Soo
Lee, Sang Ho
Park, Chan Hong
Chung, Seok Won
author_sort Kim, Hyun Jun
collection PubMed
description OBJECTIVE: Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. METHODS: A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. RESULTS: The average radiation exposure/screw was 71.45±45.75 μSv/screw for group 1, 18.77±11.51 μSv/screw for group 2, 19.58±7.00 μSv/screw for group 3, and 4.26±2.89 μSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). CONCLUSION: The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons.
format Online
Article
Text
id pubmed-8590905
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Korean Neurosurgical Society
record_format MEDLINE/PubMed
spelling pubmed-85909052021-11-18 Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion Kim, Hyun Jun Park, Eun Soo Lee, Sang Ho Park, Chan Hong Chung, Seok Won J Korean Neurosurg Soc Clinical Article OBJECTIVE: Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. METHODS: A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. RESULTS: The average radiation exposure/screw was 71.45±45.75 μSv/screw for group 1, 18.77±11.51 μSv/screw for group 2, 19.58±7.00 μSv/screw for group 3, and 4.26±2.89 μSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). CONCLUSION: The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons. Korean Neurosurgical Society 2021-11 2021-08-24 /pmc/articles/PMC8590905/ /pubmed/34420290 http://dx.doi.org/10.3340/jkns.2020.0338 Text en Copyright © 2021 The Korean Neurosurgical Society https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Article
Kim, Hyun Jun
Park, Eun Soo
Lee, Sang Ho
Park, Chan Hong
Chung, Seok Won
Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion
title Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion
title_full Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion
title_fullStr Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion
title_full_unstemmed Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion
title_short Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion
title_sort reduction of radiation exposure by modifying imaging manner and fluoroscopic settings during percutaneous pedicle screw insertion
topic Clinical Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8590905/
https://www.ncbi.nlm.nih.gov/pubmed/34420290
http://dx.doi.org/10.3340/jkns.2020.0338
work_keys_str_mv AT kimhyunjun reductionofradiationexposurebymodifyingimagingmannerandfluoroscopicsettingsduringpercutaneouspediclescrewinsertion
AT parkeunsoo reductionofradiationexposurebymodifyingimagingmannerandfluoroscopicsettingsduringpercutaneouspediclescrewinsertion
AT leesangho reductionofradiationexposurebymodifyingimagingmannerandfluoroscopicsettingsduringpercutaneouspediclescrewinsertion
AT parkchanhong reductionofradiationexposurebymodifyingimagingmannerandfluoroscopicsettingsduringpercutaneouspediclescrewinsertion
AT chungseokwon reductionofradiationexposurebymodifyingimagingmannerandfluoroscopicsettingsduringpercutaneouspediclescrewinsertion