Cargando…
Peak flow measurements in patients with severe aortic stenosis: a prospective comparative study between cardiovascular magnetic resonance 2D and 4D flow and transthoracic echocardiography
BACKGROUND: Aortic valve stenosis (AS) is the most prevalent valvular disease in the developed countries. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) is an emerging imaging technique, which has been suggested to improve the evaluation of AS severity compared to two-dimensional...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8591846/ https://www.ncbi.nlm.nih.gov/pubmed/34775954 http://dx.doi.org/10.1186/s12968-021-00825-1 |
_version_ | 1784599339550638080 |
---|---|
author | Hälvä, Reetta Vaara, Satu M. Peltonen, Juha I. Kaasalainen, Touko T. Holmström, Miia Lommi, Jyri Suihko, Satu Rajala, Helena Kylmälä, Minna Kivistö, Sari Syväranta, Suvi |
author_facet | Hälvä, Reetta Vaara, Satu M. Peltonen, Juha I. Kaasalainen, Touko T. Holmström, Miia Lommi, Jyri Suihko, Satu Rajala, Helena Kylmälä, Minna Kivistö, Sari Syväranta, Suvi |
author_sort | Hälvä, Reetta |
collection | PubMed |
description | BACKGROUND: Aortic valve stenosis (AS) is the most prevalent valvular disease in the developed countries. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) is an emerging imaging technique, which has been suggested to improve the evaluation of AS severity compared to two-dimensional (2D) flow and transthoracic echocardiography (TTE). We investigated the reliability of CMR 2D flow and 4D flow techniques in measuring aortic transvalvular peak systolic flow in patients with severe AS. METHODS: We prospectively recruited 90 patients referred for aortic valve replacement due to severe AS (73.3 ± 11.3 years, aortic valve area 0.7 ± 0.1 cm(2), and 54/36 tricuspid/bicuspid), and 10 non-valvular disease controls. All the patients underwent echocardiography and 2D flow and 4D flow CMR. Peak flow velocity measurements were compared using Wilcoxon signed rank sum test and Bland–Altman analysis. RESULTS: 4D flow underestimated peak flow velocity in the AS group when compared with TTE (bias − 1.1 m/s, limits of agreement ± 1.4 m/s) and 2D flow (bias − 1.2 m/s, limits of agreement ± 1.6 m/s). The differences between values obtained by TTE (median 4.3 m/s, range 2.7–6.1 m/s) and 2D flow (median 4.5 m/s, range 2.9–6.5 m/s) compared to 4D flow (median 3.1 m/s, range 1.7–5.1 m/s) were significant (p < 0.001). The difference between 2D flow and TTE were insignificant (bias 0.07 m/s, limits of agreement ± 1.5 m/s). In non-valvular disease controls, peak flow velocity was measured higher by 4D flow than 2D flow (1.4 m/s, 1.1–1.7 m/s and 1.3 m/s, 1.1–1.5 m/s, respectively; bias 0.2 m/s, limits of agreement ± 0.16 m/s). CONCLUSIONS: CMR 4D flow significantly underestimates systolic peak flow velocity in patients with severe AS. 2D flow, in turn, estimated the AS velocity accurately, with measured peak flow velocities comparable to TTE. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12968-021-00825-1. |
format | Online Article Text |
id | pubmed-8591846 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-85918462021-11-15 Peak flow measurements in patients with severe aortic stenosis: a prospective comparative study between cardiovascular magnetic resonance 2D and 4D flow and transthoracic echocardiography Hälvä, Reetta Vaara, Satu M. Peltonen, Juha I. Kaasalainen, Touko T. Holmström, Miia Lommi, Jyri Suihko, Satu Rajala, Helena Kylmälä, Minna Kivistö, Sari Syväranta, Suvi J Cardiovasc Magn Reson Research BACKGROUND: Aortic valve stenosis (AS) is the most prevalent valvular disease in the developed countries. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) is an emerging imaging technique, which has been suggested to improve the evaluation of AS severity compared to two-dimensional (2D) flow and transthoracic echocardiography (TTE). We investigated the reliability of CMR 2D flow and 4D flow techniques in measuring aortic transvalvular peak systolic flow in patients with severe AS. METHODS: We prospectively recruited 90 patients referred for aortic valve replacement due to severe AS (73.3 ± 11.3 years, aortic valve area 0.7 ± 0.1 cm(2), and 54/36 tricuspid/bicuspid), and 10 non-valvular disease controls. All the patients underwent echocardiography and 2D flow and 4D flow CMR. Peak flow velocity measurements were compared using Wilcoxon signed rank sum test and Bland–Altman analysis. RESULTS: 4D flow underestimated peak flow velocity in the AS group when compared with TTE (bias − 1.1 m/s, limits of agreement ± 1.4 m/s) and 2D flow (bias − 1.2 m/s, limits of agreement ± 1.6 m/s). The differences between values obtained by TTE (median 4.3 m/s, range 2.7–6.1 m/s) and 2D flow (median 4.5 m/s, range 2.9–6.5 m/s) compared to 4D flow (median 3.1 m/s, range 1.7–5.1 m/s) were significant (p < 0.001). The difference between 2D flow and TTE were insignificant (bias 0.07 m/s, limits of agreement ± 1.5 m/s). In non-valvular disease controls, peak flow velocity was measured higher by 4D flow than 2D flow (1.4 m/s, 1.1–1.7 m/s and 1.3 m/s, 1.1–1.5 m/s, respectively; bias 0.2 m/s, limits of agreement ± 0.16 m/s). CONCLUSIONS: CMR 4D flow significantly underestimates systolic peak flow velocity in patients with severe AS. 2D flow, in turn, estimated the AS velocity accurately, with measured peak flow velocities comparable to TTE. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12968-021-00825-1. BioMed Central 2021-11-15 /pmc/articles/PMC8591846/ /pubmed/34775954 http://dx.doi.org/10.1186/s12968-021-00825-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Hälvä, Reetta Vaara, Satu M. Peltonen, Juha I. Kaasalainen, Touko T. Holmström, Miia Lommi, Jyri Suihko, Satu Rajala, Helena Kylmälä, Minna Kivistö, Sari Syväranta, Suvi Peak flow measurements in patients with severe aortic stenosis: a prospective comparative study between cardiovascular magnetic resonance 2D and 4D flow and transthoracic echocardiography |
title | Peak flow measurements in patients with severe aortic stenosis: a prospective comparative study between cardiovascular magnetic resonance 2D and 4D flow and transthoracic echocardiography |
title_full | Peak flow measurements in patients with severe aortic stenosis: a prospective comparative study between cardiovascular magnetic resonance 2D and 4D flow and transthoracic echocardiography |
title_fullStr | Peak flow measurements in patients with severe aortic stenosis: a prospective comparative study between cardiovascular magnetic resonance 2D and 4D flow and transthoracic echocardiography |
title_full_unstemmed | Peak flow measurements in patients with severe aortic stenosis: a prospective comparative study between cardiovascular magnetic resonance 2D and 4D flow and transthoracic echocardiography |
title_short | Peak flow measurements in patients with severe aortic stenosis: a prospective comparative study between cardiovascular magnetic resonance 2D and 4D flow and transthoracic echocardiography |
title_sort | peak flow measurements in patients with severe aortic stenosis: a prospective comparative study between cardiovascular magnetic resonance 2d and 4d flow and transthoracic echocardiography |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8591846/ https://www.ncbi.nlm.nih.gov/pubmed/34775954 http://dx.doi.org/10.1186/s12968-021-00825-1 |
work_keys_str_mv | AT halvareetta peakflowmeasurementsinpatientswithsevereaorticstenosisaprospectivecomparativestudybetweencardiovascularmagneticresonance2dand4dflowandtransthoracicechocardiography AT vaarasatum peakflowmeasurementsinpatientswithsevereaorticstenosisaprospectivecomparativestudybetweencardiovascularmagneticresonance2dand4dflowandtransthoracicechocardiography AT peltonenjuhai peakflowmeasurementsinpatientswithsevereaorticstenosisaprospectivecomparativestudybetweencardiovascularmagneticresonance2dand4dflowandtransthoracicechocardiography AT kaasalainentoukot peakflowmeasurementsinpatientswithsevereaorticstenosisaprospectivecomparativestudybetweencardiovascularmagneticresonance2dand4dflowandtransthoracicechocardiography AT holmstrommiia peakflowmeasurementsinpatientswithsevereaorticstenosisaprospectivecomparativestudybetweencardiovascularmagneticresonance2dand4dflowandtransthoracicechocardiography AT lommijyri peakflowmeasurementsinpatientswithsevereaorticstenosisaprospectivecomparativestudybetweencardiovascularmagneticresonance2dand4dflowandtransthoracicechocardiography AT suihkosatu peakflowmeasurementsinpatientswithsevereaorticstenosisaprospectivecomparativestudybetweencardiovascularmagneticresonance2dand4dflowandtransthoracicechocardiography AT rajalahelena peakflowmeasurementsinpatientswithsevereaorticstenosisaprospectivecomparativestudybetweencardiovascularmagneticresonance2dand4dflowandtransthoracicechocardiography AT kylmalaminna peakflowmeasurementsinpatientswithsevereaorticstenosisaprospectivecomparativestudybetweencardiovascularmagneticresonance2dand4dflowandtransthoracicechocardiography AT kivistosari peakflowmeasurementsinpatientswithsevereaorticstenosisaprospectivecomparativestudybetweencardiovascularmagneticresonance2dand4dflowandtransthoracicechocardiography AT syvarantasuvi peakflowmeasurementsinpatientswithsevereaorticstenosisaprospectivecomparativestudybetweencardiovascularmagneticresonance2dand4dflowandtransthoracicechocardiography |