Cargando…
Oesophageal IGRT considerations for SBRT of LA-NSCLC: barium-enhanced CBCT and interfraction motion
BACKGROUND: To determine the optimal volume of barium for oesophageal localisation on cone-beam CT (CBCT) for locally-advanced non-small cell lung cancers (NSCLC) and quantify the interfraction oesophageal movement relative to tumour. METHODS: Twenty NSCLC patients with mediastinal and/or hilar dise...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8591953/ https://www.ncbi.nlm.nih.gov/pubmed/34775990 http://dx.doi.org/10.1186/s13014-021-01946-8 |
_version_ | 1784599366393135104 |
---|---|
author | Woodford, Katrina Panettieri, Vanessa Ruben, Jeremy D. Davis, Sidney Tran Le, Trieumy Miller, Stephanie Senthi, Sashendra |
author_facet | Woodford, Katrina Panettieri, Vanessa Ruben, Jeremy D. Davis, Sidney Tran Le, Trieumy Miller, Stephanie Senthi, Sashendra |
author_sort | Woodford, Katrina |
collection | PubMed |
description | BACKGROUND: To determine the optimal volume of barium for oesophageal localisation on cone-beam CT (CBCT) for locally-advanced non-small cell lung cancers (NSCLC) and quantify the interfraction oesophageal movement relative to tumour. METHODS: Twenty NSCLC patients with mediastinal and/or hilar disease receiving radical radiotherapy were recruited. The first five patients received 25 ml of barium prior to their planning CT and alternate CBCTs during treatment. Subsequent five patient cohorts, received 15 ml, 10 ml and 5 ml. Six observers contoured the oesophagus on each of the 107 datasets and consensus contours were created. Overall 642 observer contours were generated and interobserver contouring reproducibility was assessed. The kappa statistic, dice coefficient and Hausdorff Distance (HD) were used to compare barium-enhanced CBCTs and non-enhanced CBCTs. Oesophageal displacement was assessed using the HD between consensus contours of barium-enhanced CBCTs and planning CTs. RESULTS: Interobserver contouring reproducibility was significantly improved in barium-enhanced CBCTs compared to non-contrast CBCTs with minimal difference between barium dose levels. Only 10 mL produced a significantly higher kappa (0.814, p = 0.008) and dice (0.895, p = 0.001). The poorer the reproducibility without barium, the greater the improvement barium provided. The median interfraction HD between consensus contours was 4 mm, with 95% of the oesophageal displacement within 15 mm. CONCLUSIONS: 10 mL of barium significantly improves oesophageal localisation on CBCT with minimal image artifact. The oesophagus moves substantially and unpredictably over a course of treatment, requiring close daily monitoring in the context of hypofractionation. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-021-01946-8. |
format | Online Article Text |
id | pubmed-8591953 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-85919532021-11-15 Oesophageal IGRT considerations for SBRT of LA-NSCLC: barium-enhanced CBCT and interfraction motion Woodford, Katrina Panettieri, Vanessa Ruben, Jeremy D. Davis, Sidney Tran Le, Trieumy Miller, Stephanie Senthi, Sashendra Radiat Oncol Research BACKGROUND: To determine the optimal volume of barium for oesophageal localisation on cone-beam CT (CBCT) for locally-advanced non-small cell lung cancers (NSCLC) and quantify the interfraction oesophageal movement relative to tumour. METHODS: Twenty NSCLC patients with mediastinal and/or hilar disease receiving radical radiotherapy were recruited. The first five patients received 25 ml of barium prior to their planning CT and alternate CBCTs during treatment. Subsequent five patient cohorts, received 15 ml, 10 ml and 5 ml. Six observers contoured the oesophagus on each of the 107 datasets and consensus contours were created. Overall 642 observer contours were generated and interobserver contouring reproducibility was assessed. The kappa statistic, dice coefficient and Hausdorff Distance (HD) were used to compare barium-enhanced CBCTs and non-enhanced CBCTs. Oesophageal displacement was assessed using the HD between consensus contours of barium-enhanced CBCTs and planning CTs. RESULTS: Interobserver contouring reproducibility was significantly improved in barium-enhanced CBCTs compared to non-contrast CBCTs with minimal difference between barium dose levels. Only 10 mL produced a significantly higher kappa (0.814, p = 0.008) and dice (0.895, p = 0.001). The poorer the reproducibility without barium, the greater the improvement barium provided. The median interfraction HD between consensus contours was 4 mm, with 95% of the oesophageal displacement within 15 mm. CONCLUSIONS: 10 mL of barium significantly improves oesophageal localisation on CBCT with minimal image artifact. The oesophagus moves substantially and unpredictably over a course of treatment, requiring close daily monitoring in the context of hypofractionation. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13014-021-01946-8. BioMed Central 2021-11-14 /pmc/articles/PMC8591953/ /pubmed/34775990 http://dx.doi.org/10.1186/s13014-021-01946-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Woodford, Katrina Panettieri, Vanessa Ruben, Jeremy D. Davis, Sidney Tran Le, Trieumy Miller, Stephanie Senthi, Sashendra Oesophageal IGRT considerations for SBRT of LA-NSCLC: barium-enhanced CBCT and interfraction motion |
title | Oesophageal IGRT considerations for SBRT of LA-NSCLC: barium-enhanced CBCT and interfraction motion |
title_full | Oesophageal IGRT considerations for SBRT of LA-NSCLC: barium-enhanced CBCT and interfraction motion |
title_fullStr | Oesophageal IGRT considerations for SBRT of LA-NSCLC: barium-enhanced CBCT and interfraction motion |
title_full_unstemmed | Oesophageal IGRT considerations for SBRT of LA-NSCLC: barium-enhanced CBCT and interfraction motion |
title_short | Oesophageal IGRT considerations for SBRT of LA-NSCLC: barium-enhanced CBCT and interfraction motion |
title_sort | oesophageal igrt considerations for sbrt of la-nsclc: barium-enhanced cbct and interfraction motion |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8591953/ https://www.ncbi.nlm.nih.gov/pubmed/34775990 http://dx.doi.org/10.1186/s13014-021-01946-8 |
work_keys_str_mv | AT woodfordkatrina oesophagealigrtconsiderationsforsbrtoflansclcbariumenhancedcbctandinterfractionmotion AT panettierivanessa oesophagealigrtconsiderationsforsbrtoflansclcbariumenhancedcbctandinterfractionmotion AT rubenjeremyd oesophagealigrtconsiderationsforsbrtoflansclcbariumenhancedcbctandinterfractionmotion AT davissidney oesophagealigrtconsiderationsforsbrtoflansclcbariumenhancedcbctandinterfractionmotion AT tranletrieumy oesophagealigrtconsiderationsforsbrtoflansclcbariumenhancedcbctandinterfractionmotion AT millerstephanie oesophagealigrtconsiderationsforsbrtoflansclcbariumenhancedcbctandinterfractionmotion AT senthisashendra oesophagealigrtconsiderationsforsbrtoflansclcbariumenhancedcbctandinterfractionmotion |