Cargando…

The diagnostic value of contrast-enhanced 2D mammography in everyday clinical use

Contrast-enhanced mammography (CEM) has shown to be superior to full-field digital mammography (FFDM), but current results are dominated by studies performed on systems by one vendor. Information on diagnostic accuracy of other CEM systems is limited. Therefore, we aimed to evaluate the diagnostic p...

Descripción completa

Detalles Bibliográficos
Autores principales: Neeter, L. M. F. H., Raat, H. P. J., Meens-Koreman, S. D., van Stiphout, R. S. A., Timmermans, S. M. E. C., Duvivier, K. M., Smidt, M. L., Wildberger, J. E., Nelemans, P. J., Lobbes, M. B. I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8593172/
https://www.ncbi.nlm.nih.gov/pubmed/34782698
http://dx.doi.org/10.1038/s41598-021-01622-7
_version_ 1784599663308963840
author Neeter, L. M. F. H.
Raat, H. P. J.
Meens-Koreman, S. D.
van Stiphout, R. S. A.
Timmermans, S. M. E. C.
Duvivier, K. M.
Smidt, M. L.
Wildberger, J. E.
Nelemans, P. J.
Lobbes, M. B. I.
author_facet Neeter, L. M. F. H.
Raat, H. P. J.
Meens-Koreman, S. D.
van Stiphout, R. S. A.
Timmermans, S. M. E. C.
Duvivier, K. M.
Smidt, M. L.
Wildberger, J. E.
Nelemans, P. J.
Lobbes, M. B. I.
author_sort Neeter, L. M. F. H.
collection PubMed
description Contrast-enhanced mammography (CEM) has shown to be superior to full-field digital mammography (FFDM), but current results are dominated by studies performed on systems by one vendor. Information on diagnostic accuracy of other CEM systems is limited. Therefore, we aimed to evaluate the diagnostic performance of CEM on an alternative vendor’s system. We included all patients who underwent CEM in one hospital in 2019, except those with missing data or in whom CEM was used as response monitoring tool. Three experienced breast radiologists scored the low-energy images using the BI-RADS classification. Next, the complete CEM exams were scored similarly. Histopathological results or a minimum of one year follow-up were used as reference standard. Diagnostic performance and AUC were calculated and compared between low-energy images and the complete CEM examination, for all readers independently as well as combined. Breast cancer was diagnosed in 23.0% of the patients (35/152). Compared to low-energy images, overall CEM sensitivity increased from 74.3 to 87.6% (p < 0.0001), specificity from 87.8 to 94.6% (p = 0.0146). AUC increased from 0.872 to 0.957 (p = 0.0001). Performing CEM on the system tested, showed that, similar to earlier studies mainly performed on another vendor’s systems, both sensitivity and specificity improved when compared to FFDM.
format Online
Article
Text
id pubmed-8593172
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-85931722021-11-17 The diagnostic value of contrast-enhanced 2D mammography in everyday clinical use Neeter, L. M. F. H. Raat, H. P. J. Meens-Koreman, S. D. van Stiphout, R. S. A. Timmermans, S. M. E. C. Duvivier, K. M. Smidt, M. L. Wildberger, J. E. Nelemans, P. J. Lobbes, M. B. I. Sci Rep Article Contrast-enhanced mammography (CEM) has shown to be superior to full-field digital mammography (FFDM), but current results are dominated by studies performed on systems by one vendor. Information on diagnostic accuracy of other CEM systems is limited. Therefore, we aimed to evaluate the diagnostic performance of CEM on an alternative vendor’s system. We included all patients who underwent CEM in one hospital in 2019, except those with missing data or in whom CEM was used as response monitoring tool. Three experienced breast radiologists scored the low-energy images using the BI-RADS classification. Next, the complete CEM exams were scored similarly. Histopathological results or a minimum of one year follow-up were used as reference standard. Diagnostic performance and AUC were calculated and compared between low-energy images and the complete CEM examination, for all readers independently as well as combined. Breast cancer was diagnosed in 23.0% of the patients (35/152). Compared to low-energy images, overall CEM sensitivity increased from 74.3 to 87.6% (p < 0.0001), specificity from 87.8 to 94.6% (p = 0.0146). AUC increased from 0.872 to 0.957 (p = 0.0001). Performing CEM on the system tested, showed that, similar to earlier studies mainly performed on another vendor’s systems, both sensitivity and specificity improved when compared to FFDM. Nature Publishing Group UK 2021-11-15 /pmc/articles/PMC8593172/ /pubmed/34782698 http://dx.doi.org/10.1038/s41598-021-01622-7 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Neeter, L. M. F. H.
Raat, H. P. J.
Meens-Koreman, S. D.
van Stiphout, R. S. A.
Timmermans, S. M. E. C.
Duvivier, K. M.
Smidt, M. L.
Wildberger, J. E.
Nelemans, P. J.
Lobbes, M. B. I.
The diagnostic value of contrast-enhanced 2D mammography in everyday clinical use
title The diagnostic value of contrast-enhanced 2D mammography in everyday clinical use
title_full The diagnostic value of contrast-enhanced 2D mammography in everyday clinical use
title_fullStr The diagnostic value of contrast-enhanced 2D mammography in everyday clinical use
title_full_unstemmed The diagnostic value of contrast-enhanced 2D mammography in everyday clinical use
title_short The diagnostic value of contrast-enhanced 2D mammography in everyday clinical use
title_sort diagnostic value of contrast-enhanced 2d mammography in everyday clinical use
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8593172/
https://www.ncbi.nlm.nih.gov/pubmed/34782698
http://dx.doi.org/10.1038/s41598-021-01622-7
work_keys_str_mv AT neeterlmfh thediagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT raathpj thediagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT meenskoremansd thediagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT vanstiphoutrsa thediagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT timmermanssmec thediagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT duvivierkm thediagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT smidtml thediagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT wildbergerje thediagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT nelemanspj thediagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT lobbesmbi thediagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT neeterlmfh diagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT raathpj diagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT meenskoremansd diagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT vanstiphoutrsa diagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT timmermanssmec diagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT duvivierkm diagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT smidtml diagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT wildbergerje diagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT nelemanspj diagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse
AT lobbesmbi diagnosticvalueofcontrastenhanced2dmammographyineverydayclinicaluse