Case Report: Internal Carotid Artery Thrombosis: A Rare Complication After Fibrin Glue Injection for Cavernous Sinus Hemostasis
Background: Fibrin glue injection within the cavernous sinus (CS) is a demonstrably safe and simple technique to control venous bleeding with a low complication rate. However, this technique does have inherent risks. We illustrate 2 cases of internal carotid artery (ICA) thrombosis after fibrin glue...
Autores principales: | Andrade-Barazarte, Hugo, Chen, Zhongcan, Feng, Chenyi, Srinivasan, Visish M., Furey, Charuta G., Lawton, Michael T., Hernesniemi, Juha |
---|---|