Cargando…

Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis

BACKGROUND: The traditional strategy for fixing intra-articular distal humerus fractures is double plating placed in an orthogonal configuration, based on posterior approach. With a combined medial and lateral approach, a novel configuration of plating (combined anteromedial and anterolateral platin...

Descripción completa

Detalles Bibliográficos
Autores principales: Kong, Lingpeng, Wang, Yan, Lu, Qingsen, Han, Yong, Wang, Fu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8594201/
https://www.ncbi.nlm.nih.gov/pubmed/34784932
http://dx.doi.org/10.1186/s13018-021-02836-1
_version_ 1784599921154850816
author Kong, Lingpeng
Wang, Yan
Lu, Qingsen
Han, Yong
Wang, Fu
author_facet Kong, Lingpeng
Wang, Yan
Lu, Qingsen
Han, Yong
Wang, Fu
author_sort Kong, Lingpeng
collection PubMed
description BACKGROUND: The traditional strategy for fixing intra-articular distal humerus fractures is double plating placed in an orthogonal configuration, based on posterior approach. With a combined medial and lateral approach, a novel configuration of plating (combined anteromedial and anterolateral plating) has been used. In this study, we investigated the biomechanical properties of the novel plating by comparing it with some traditional strategies. METHODS: Based on the 3D morphology of a healthy subject’s humerus, models of three types of intra-articular distal humeral fractures were established using a variety of different internal fixation methods: (a) treatment of a simple intra-articular fracture of the distal humerus with the novel double plate and a traditional orthogonal plate; (b) treatment of a comminuted fracture of the lower distal humerus with the novel double plate, a traditional orthogonal plate and a traditional orthogonal plate combined with distally extended tension screws; (c) treatment of a coronal shear fracture of the distal humerus with the novel double plate, a traditional orthogonal plate and the intra-articular placement of three screws. The material properties of all plates and screws were isotropic and linearly elastic. The Poisson ratio of the implant and bone was 0.3, and the elastic modulus of the implant was 114,000 MPa. The axial loading is 200 N, the bending loading is 30 N and varus rotation is 7.5 Nm in the longitudinal direction. RESULTS: A simple model of intra-articular fracture of the distal humerus (AO C1 type) was established. Under all experimental conditions, the novel double plate showed greater stiffness than the orthogonal double plate. The axial straightening, bending compression and varus torsion increased by 18.00%, 16.00% and 44.00%, respectively. In the model of comminuted fracture of the lower distal humerus, the novel double plate showed the best stiffness under three experimental conditions (163.93 N/mm, 37.97 N/mm, 2697.84 N mm/°), and the stiffness of the traditional orthogonal plate combined with the distally extended tension screws was similar to that of the traditional orthogonal plate (121.21 N/mm, 32.61 N/mm, 1968.50 N mm/°). In the model of coronal shear fracture of the distal humerus, the novel double plate showed the best stiffness under all test conditions (194.17 N/mm, 38.46 N/mm, 2929.69 N mm/°), followed by the traditional plate (153.85 N/mm, 33.33 N/mm, 2650.18 N mm/°), while the stiffness of the three screws was the smallest (115.61 N/mm, 28.30 N/mm, 2180.23 N mm/°). CONCLUSIONS: In terms of biomechanics, compared with other internal fixation methods, the novel combined anteromedial and anterolateral anatomical locking double-plate showed less stress, less displacement and greater stiffness. The novel double-plate method can be used to treat not only simple intra-articular fractures of the humerus but also complex comminuted fractures of the lower distal humerus and coronal shear fractures of the distal humerus, with a better effect than current traditional internal fixation methods.
format Online
Article
Text
id pubmed-8594201
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-85942012021-11-16 Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis Kong, Lingpeng Wang, Yan Lu, Qingsen Han, Yong Wang, Fu J Orthop Surg Res Research Article BACKGROUND: The traditional strategy for fixing intra-articular distal humerus fractures is double plating placed in an orthogonal configuration, based on posterior approach. With a combined medial and lateral approach, a novel configuration of plating (combined anteromedial and anterolateral plating) has been used. In this study, we investigated the biomechanical properties of the novel plating by comparing it with some traditional strategies. METHODS: Based on the 3D morphology of a healthy subject’s humerus, models of three types of intra-articular distal humeral fractures were established using a variety of different internal fixation methods: (a) treatment of a simple intra-articular fracture of the distal humerus with the novel double plate and a traditional orthogonal plate; (b) treatment of a comminuted fracture of the lower distal humerus with the novel double plate, a traditional orthogonal plate and a traditional orthogonal plate combined with distally extended tension screws; (c) treatment of a coronal shear fracture of the distal humerus with the novel double plate, a traditional orthogonal plate and the intra-articular placement of three screws. The material properties of all plates and screws were isotropic and linearly elastic. The Poisson ratio of the implant and bone was 0.3, and the elastic modulus of the implant was 114,000 MPa. The axial loading is 200 N, the bending loading is 30 N and varus rotation is 7.5 Nm in the longitudinal direction. RESULTS: A simple model of intra-articular fracture of the distal humerus (AO C1 type) was established. Under all experimental conditions, the novel double plate showed greater stiffness than the orthogonal double plate. The axial straightening, bending compression and varus torsion increased by 18.00%, 16.00% and 44.00%, respectively. In the model of comminuted fracture of the lower distal humerus, the novel double plate showed the best stiffness under three experimental conditions (163.93 N/mm, 37.97 N/mm, 2697.84 N mm/°), and the stiffness of the traditional orthogonal plate combined with the distally extended tension screws was similar to that of the traditional orthogonal plate (121.21 N/mm, 32.61 N/mm, 1968.50 N mm/°). In the model of coronal shear fracture of the distal humerus, the novel double plate showed the best stiffness under all test conditions (194.17 N/mm, 38.46 N/mm, 2929.69 N mm/°), followed by the traditional plate (153.85 N/mm, 33.33 N/mm, 2650.18 N mm/°), while the stiffness of the three screws was the smallest (115.61 N/mm, 28.30 N/mm, 2180.23 N mm/°). CONCLUSIONS: In terms of biomechanics, compared with other internal fixation methods, the novel combined anteromedial and anterolateral anatomical locking double-plate showed less stress, less displacement and greater stiffness. The novel double-plate method can be used to treat not only simple intra-articular fractures of the humerus but also complex comminuted fractures of the lower distal humerus and coronal shear fractures of the distal humerus, with a better effect than current traditional internal fixation methods. BioMed Central 2021-11-16 /pmc/articles/PMC8594201/ /pubmed/34784932 http://dx.doi.org/10.1186/s13018-021-02836-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Kong, Lingpeng
Wang, Yan
Lu, Qingsen
Han, Yong
Wang, Fu
Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis
title Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis
title_full Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis
title_fullStr Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis
title_full_unstemmed Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis
title_short Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis
title_sort biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8594201/
https://www.ncbi.nlm.nih.gov/pubmed/34784932
http://dx.doi.org/10.1186/s13018-021-02836-1
work_keys_str_mv AT konglingpeng biomechanicalpropertiesofanovelfixationsystemforintraarticulardistalhumerusfracturesafiniteelementanalysis
AT wangyan biomechanicalpropertiesofanovelfixationsystemforintraarticulardistalhumerusfracturesafiniteelementanalysis
AT luqingsen biomechanicalpropertiesofanovelfixationsystemforintraarticulardistalhumerusfracturesafiniteelementanalysis
AT hanyong biomechanicalpropertiesofanovelfixationsystemforintraarticulardistalhumerusfracturesafiniteelementanalysis
AT wangfu biomechanicalpropertiesofanovelfixationsystemforintraarticulardistalhumerusfracturesafiniteelementanalysis