Cargando…
Understand the difference between clinical measured ultrafiltrationand real ultrafiltration in peritoneal dialysis
BACKGROUND: It has been noticed for years that ultrafiltration (UF) is important for survival in peritoneal dialysis. On the other hand, precise and convenient UF measurement suitable for patient daily practice is not as straight forward as it is to measure UF in the lab. Both overfill and flush bef...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8594243/ https://www.ncbi.nlm.nih.gov/pubmed/34781890 http://dx.doi.org/10.1186/s12882-021-02589-3 |
_version_ | 1784599930193575936 |
---|---|
author | Yu, Zanzhe Wang, Zhuqing Wang, Qin Zhang, Minfang Jin, Haijiao Ding, Li Yan, Hao Huang, Jiaying Jin, Yan Davies, Simon Fang, Wei Ni, Zhaohui |
author_facet | Yu, Zanzhe Wang, Zhuqing Wang, Qin Zhang, Minfang Jin, Haijiao Ding, Li Yan, Hao Huang, Jiaying Jin, Yan Davies, Simon Fang, Wei Ni, Zhaohui |
author_sort | Yu, Zanzhe |
collection | PubMed |
description | BACKGROUND: It has been noticed for years that ultrafiltration (UF) is important for survival in peritoneal dialysis. On the other hand, precise and convenient UF measurement suitable for patient daily practice is not as straight forward as it is to measure UF in the lab. Both overfill and flush before fill used to be source of measurement error for clinical practice. However, controversy finding around UF in peritoneal dialysis still exists in some situation. The current study was to understand the difference between clinical measured UF and real UF. The effect of evaporation and specific gravity in clinical UF measurement were tested in the study. METHODS: Four different brands of dialysate were purchased from the market. The freshest dialysate available in the market were intentionally picked. The bags were all 2 L, 2.5% dextrose and traditional lactate buffered PD solution. They were stored in four different conditions with controlled temperature and humidity. The bags were weighted at baseline, 6 months and 12 months of storage. Specific gravity was measured in mixed 24 h drainage dialysate from 261 CAPD patients when they come for their routine solute clearance test. RESULTS: There was significant difference in dialysate bag weight at baseline between brands. The weight declined significantly after 12 month’s storage. The weight loss was greater in higher temperature and lower humidity. The dialysate in non-PVC package lose less weight than PVC package. The specific gravity of dialysate drainage was significantly higher than pure water and it was related to dialysate protein concentration. CONCLUSION: Storage condition and duration, as well as the type of dialysate package have significant impact in dialysate bag weight before use. Evaporation is likely to be the reason behind. The fact that specific gravity of dialysate drainage is higher than 1 g/ml overestimates UF in manual exchanges, which contributes to systemic measurement error of ultrafiltration in CAPD. TRIAL REGISTRATION: ClinicalTrials.gov ID: NCT03864120 (March 8, 2019) (Understand the Difference Between Clinical Measured Ultrafiltration and Real Ultrafiltration). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12882-021-02589-3. |
format | Online Article Text |
id | pubmed-8594243 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-85942432021-11-16 Understand the difference between clinical measured ultrafiltrationand real ultrafiltration in peritoneal dialysis Yu, Zanzhe Wang, Zhuqing Wang, Qin Zhang, Minfang Jin, Haijiao Ding, Li Yan, Hao Huang, Jiaying Jin, Yan Davies, Simon Fang, Wei Ni, Zhaohui BMC Nephrol Research BACKGROUND: It has been noticed for years that ultrafiltration (UF) is important for survival in peritoneal dialysis. On the other hand, precise and convenient UF measurement suitable for patient daily practice is not as straight forward as it is to measure UF in the lab. Both overfill and flush before fill used to be source of measurement error for clinical practice. However, controversy finding around UF in peritoneal dialysis still exists in some situation. The current study was to understand the difference between clinical measured UF and real UF. The effect of evaporation and specific gravity in clinical UF measurement were tested in the study. METHODS: Four different brands of dialysate were purchased from the market. The freshest dialysate available in the market were intentionally picked. The bags were all 2 L, 2.5% dextrose and traditional lactate buffered PD solution. They were stored in four different conditions with controlled temperature and humidity. The bags were weighted at baseline, 6 months and 12 months of storage. Specific gravity was measured in mixed 24 h drainage dialysate from 261 CAPD patients when they come for their routine solute clearance test. RESULTS: There was significant difference in dialysate bag weight at baseline between brands. The weight declined significantly after 12 month’s storage. The weight loss was greater in higher temperature and lower humidity. The dialysate in non-PVC package lose less weight than PVC package. The specific gravity of dialysate drainage was significantly higher than pure water and it was related to dialysate protein concentration. CONCLUSION: Storage condition and duration, as well as the type of dialysate package have significant impact in dialysate bag weight before use. Evaporation is likely to be the reason behind. The fact that specific gravity of dialysate drainage is higher than 1 g/ml overestimates UF in manual exchanges, which contributes to systemic measurement error of ultrafiltration in CAPD. TRIAL REGISTRATION: ClinicalTrials.gov ID: NCT03864120 (March 8, 2019) (Understand the Difference Between Clinical Measured Ultrafiltration and Real Ultrafiltration). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12882-021-02589-3. BioMed Central 2021-11-15 /pmc/articles/PMC8594243/ /pubmed/34781890 http://dx.doi.org/10.1186/s12882-021-02589-3 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Yu, Zanzhe Wang, Zhuqing Wang, Qin Zhang, Minfang Jin, Haijiao Ding, Li Yan, Hao Huang, Jiaying Jin, Yan Davies, Simon Fang, Wei Ni, Zhaohui Understand the difference between clinical measured ultrafiltrationand real ultrafiltration in peritoneal dialysis |
title | Understand the difference between clinical measured ultrafiltrationand real ultrafiltration in peritoneal dialysis |
title_full | Understand the difference between clinical measured ultrafiltrationand real ultrafiltration in peritoneal dialysis |
title_fullStr | Understand the difference between clinical measured ultrafiltrationand real ultrafiltration in peritoneal dialysis |
title_full_unstemmed | Understand the difference between clinical measured ultrafiltrationand real ultrafiltration in peritoneal dialysis |
title_short | Understand the difference between clinical measured ultrafiltrationand real ultrafiltration in peritoneal dialysis |
title_sort | understand the difference between clinical measured ultrafiltrationand real ultrafiltration in peritoneal dialysis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8594243/ https://www.ncbi.nlm.nih.gov/pubmed/34781890 http://dx.doi.org/10.1186/s12882-021-02589-3 |
work_keys_str_mv | AT yuzanzhe understandthedifferencebetweenclinicalmeasuredultrafiltrationandrealultrafiltrationinperitonealdialysis AT wangzhuqing understandthedifferencebetweenclinicalmeasuredultrafiltrationandrealultrafiltrationinperitonealdialysis AT wangqin understandthedifferencebetweenclinicalmeasuredultrafiltrationandrealultrafiltrationinperitonealdialysis AT zhangminfang understandthedifferencebetweenclinicalmeasuredultrafiltrationandrealultrafiltrationinperitonealdialysis AT jinhaijiao understandthedifferencebetweenclinicalmeasuredultrafiltrationandrealultrafiltrationinperitonealdialysis AT dingli understandthedifferencebetweenclinicalmeasuredultrafiltrationandrealultrafiltrationinperitonealdialysis AT yanhao understandthedifferencebetweenclinicalmeasuredultrafiltrationandrealultrafiltrationinperitonealdialysis AT huangjiaying understandthedifferencebetweenclinicalmeasuredultrafiltrationandrealultrafiltrationinperitonealdialysis AT jinyan understandthedifferencebetweenclinicalmeasuredultrafiltrationandrealultrafiltrationinperitonealdialysis AT daviessimon understandthedifferencebetweenclinicalmeasuredultrafiltrationandrealultrafiltrationinperitonealdialysis AT fangwei understandthedifferencebetweenclinicalmeasuredultrafiltrationandrealultrafiltrationinperitonealdialysis AT nizhaohui understandthedifferencebetweenclinicalmeasuredultrafiltrationandrealultrafiltrationinperitonealdialysis |