The effective treatment of wide necked cerebral aneurysms located at vessel bifurcations (WNBAs) remains a significant challenge. Such aneurysm geometries have typically been approached with Y or T stenting configurations of stents and/or flow diverters, often with the addition of endovascular coils...

Descripción completa

Detalles Bibliográficos
Autores principales: Lyu, Mengzhe, Ventikos, Yiannis, Peach, Thomas W., Makalanda, Levansri, Bhogal, Pervinder
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8595090/
https://www.ncbi.nlm.nih.gov/pubmed/34803876
http://dx.doi.org/10.3389/fneur.2021.726980
_version_ 1784600119616733184
author Lyu, Mengzhe
Ventikos, Yiannis
Peach, Thomas W.
Makalanda, Levansri
Bhogal, Pervinder
author_facet Lyu, Mengzhe
Ventikos, Yiannis
Peach, Thomas W.
Makalanda, Levansri
Bhogal, Pervinder
author_sort Lyu, Mengzhe
collection PubMed
description The effective treatment of wide necked cerebral aneurysms located at vessel bifurcations (WNBAs) remains a significant challenge. Such aneurysm geometries have typically been approached with Y or T stenting configurations of stents and/or flow diverters, often with the addition of endovascular coils. In this study, two WNBAs were virtually treated by a novel T-stenting technique (Flow-T) with a number of braided stents and flow-diverter devices. Multiple possible device deployment configurations with varying device compression levels were tested, using fast-deployment algorithms, before a steady state computational hemodynamic simulation was conducted to examine the efficacy and performance of each scenario. The virtual fast deployment algorithm based on a linear and torsional spring analogy is used to accurately deploy nine stents in two WNBAs geometries. The devices expand from the distal to proximal side of the devices with respect to aneurysm sac. In the WNBAs modelled, all configurations of Flow-T device placement were shown to reduce factors linked with increased aneurysm rupture risk including aneurysm inflow jets and high aneurysm velocity, along with areas of flow impingement and elevated wall shear stress (WSS). The relative position of the flow-diverting device in the secondary daughter vessel in the Flow-T approach was found to have a negligible effect on overall effectiveness of the procedure in the two geometries considered. The level of interventionalist-applied compression in the braised stent that forms the other arm of the Flow-T approach was shown to impact the aneurysm inflow reduction and aneurysm flow pattern more substantially. In the Flow-T approach the relative position of the secondary daughter vessel flow-diverter device (the SVB) was found to have a negligible effect on inflow reduction, aneurysm flow pattern, or WSS distribution in both aneurysm geometries. This suggests that the device placement in this vessel may be of secondary importance. By contrast, substantially more variation in inflow reduction and aneurysm flow pattern was seen due to variations in braided stent (LVIS EVO or Baby Leo) compression at the aneurysm neck. As such we conclude that the success of a Flow-T procedure is primarily dictated by the level of compression that the interventionalist applies to the braided stent. Similar computationally predicted outcomes for both aneurysm geometries studied suggest that adjunct coiling approach taken in the clinical intervention of the second geometry may have been unnecessary for successful aneurysm isolation. Finally, the computational modelling framework proposed offers an effective planning platform for complex endovascular techniques, such as Flow-T, where the scope of device choice and combination is large and selecting the best strategy and device combination from several candidates is vital.
format Online
Article
Text
id pubmed-8595090
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-85950902021-11-18 Virtual Flow-T Stenting for Two Patient-Specific Bifurcation Aneurysms Lyu, Mengzhe Ventikos, Yiannis Peach, Thomas W. Makalanda, Levansri Bhogal, Pervinder Front Neurol Neurology The effective treatment of wide necked cerebral aneurysms located at vessel bifurcations (WNBAs) remains a significant challenge. Such aneurysm geometries have typically been approached with Y or T stenting configurations of stents and/or flow diverters, often with the addition of endovascular coils. In this study, two WNBAs were virtually treated by a novel T-stenting technique (Flow-T) with a number of braided stents and flow-diverter devices. Multiple possible device deployment configurations with varying device compression levels were tested, using fast-deployment algorithms, before a steady state computational hemodynamic simulation was conducted to examine the efficacy and performance of each scenario. The virtual fast deployment algorithm based on a linear and torsional spring analogy is used to accurately deploy nine stents in two WNBAs geometries. The devices expand from the distal to proximal side of the devices with respect to aneurysm sac. In the WNBAs modelled, all configurations of Flow-T device placement were shown to reduce factors linked with increased aneurysm rupture risk including aneurysm inflow jets and high aneurysm velocity, along with areas of flow impingement and elevated wall shear stress (WSS). The relative position of the flow-diverting device in the secondary daughter vessel in the Flow-T approach was found to have a negligible effect on overall effectiveness of the procedure in the two geometries considered. The level of interventionalist-applied compression in the braised stent that forms the other arm of the Flow-T approach was shown to impact the aneurysm inflow reduction and aneurysm flow pattern more substantially. In the Flow-T approach the relative position of the secondary daughter vessel flow-diverter device (the SVB) was found to have a negligible effect on inflow reduction, aneurysm flow pattern, or WSS distribution in both aneurysm geometries. This suggests that the device placement in this vessel may be of secondary importance. By contrast, substantially more variation in inflow reduction and aneurysm flow pattern was seen due to variations in braided stent (LVIS EVO or Baby Leo) compression at the aneurysm neck. As such we conclude that the success of a Flow-T procedure is primarily dictated by the level of compression that the interventionalist applies to the braided stent. Similar computationally predicted outcomes for both aneurysm geometries studied suggest that adjunct coiling approach taken in the clinical intervention of the second geometry may have been unnecessary for successful aneurysm isolation. Finally, the computational modelling framework proposed offers an effective planning platform for complex endovascular techniques, such as Flow-T, where the scope of device choice and combination is large and selecting the best strategy and device combination from several candidates is vital. Frontiers Media S.A. 2021-11-03 /pmc/articles/PMC8595090/ /pubmed/34803876 http://dx.doi.org/10.3389/fneur.2021.726980 Text en Copyright © 2021 Lyu, Ventikos, Peach, Makalanda and Bhogal. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Lyu, Mengzhe
Ventikos, Yiannis
Peach, Thomas W.
Makalanda, Levansri
Bhogal, Pervinder
Virtual Flow-T Stenting for Two Patient-Specific Bifurcation Aneurysms
title Virtual Flow-T Stenting for Two Patient-Specific Bifurcation Aneurysms
title_full Virtual Flow-T Stenting for Two Patient-Specific Bifurcation Aneurysms
title_fullStr Virtual Flow-T Stenting for Two Patient-Specific Bifurcation Aneurysms
title_full_unstemmed Virtual Flow-T Stenting for Two Patient-Specific Bifurcation Aneurysms
title_short Virtual Flow-T Stenting for Two Patient-Specific Bifurcation Aneurysms
title_sort virtual flow-t stenting for two patient-specific bifurcation aneurysms
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8595090/
https://www.ncbi.nlm.nih.gov/pubmed/34803876
http://dx.doi.org/10.3389/fneur.2021.726980
work_keys_str_mv AT lyumengzhe virtualflowtstentingfortwopatientspecificbifurcationaneurysms
AT ventikosyiannis virtualflowtstentingfortwopatientspecificbifurcationaneurysms
AT peachthomasw virtualflowtstentingfortwopatientspecificbifurcationaneurysms
AT makalandalevansri virtualflowtstentingfortwopatientspecificbifurcationaneurysms
AT bhogalpervinder virtualflowtstentingfortwopatientspecificbifurcationaneurysms