Cargando…
Satisfactory clinical results and low failure rate of medial collagen meniscus implant (CMI) at a minimum 20 years of follow-up
PURPOSE: The aim of the study was to evaluate the long-term clinical results, reoperations, surgical failure and complications at a minimum of 20 year of follow-up of the first 8 medial CMI scaffolds implanted by a single surgeon during a pilot European Prospective study. METHODS: Seven (88%) out of...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8595163/ https://www.ncbi.nlm.nih.gov/pubmed/33835226 http://dx.doi.org/10.1007/s00167-021-06556-1 |
Sumario: | PURPOSE: The aim of the study was to evaluate the long-term clinical results, reoperations, surgical failure and complications at a minimum of 20 year of follow-up of the first 8 medial CMI scaffolds implanted by a single surgeon during a pilot European Prospective study. METHODS: Seven (88%) out of 8 patients were contacted. The Cincinnati Score, VAS, and Lysholm score were collected. Moreover, magnetic resonance imaging (MRI) was performed on 4 patients at the last follow-up. Complications, reoperations and failures were also investigated. RESULTS: The average follow-up was 21.5 ± 0.5 years. One patient underwent TKA after 13 years from CMI implantation; a second patient underwent valgus high tibial osteotomy 8 years after the index surgery and another patient underwent anterior cruciate ligament hardware removal at 21 years of follow-up. At the final follow-up, 3 patients were rated as “Excellent”, 1 as “Good” and 2 as “Fair” according to the Lysholm score. The Cincinnati score and the VAS were substantially stable over time. The MRI showed a mild osteoarthritis progression in 3 out of 4 patients according to the Yulish score, and the CMI signal was similar to the mid-term follow-up revealing 3 cases of myxoid degeneration and 1 case of normal signal with reduced scaffold size. CONCLUSION: The medial CMI is a safe procedure: satisfactory clinical results and a low failure rate could be expected even at a long-term follow-up. For this purpose, the correct indication as well as correcting axial malalignment and addressing knee instability at the time of the index surgery is mandatory. On the other hand, a mild osteoarthritis progression could be expected even after meniscus replacement. LEVEL OF EVIDENCE: IV. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00167-021-06556-1. |
---|