Cargando…
Influence of shape-memory stent grafts on local aortic compliance
The effect of repair techniques on the biomechanics of the aorta is poorly understood, resulting in significant levels of postoperative complications for patients worldwide. This study presents a computational analysis of the influence of Nitinol-based devices on the biomechanical performance of a h...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8595172/ https://www.ncbi.nlm.nih.gov/pubmed/34541627 http://dx.doi.org/10.1007/s10237-021-01514-9 |
_version_ | 1784600139573231616 |
---|---|
author | Concannon, J. Moerman, KM Hynes, N. Sultan, S. McGarry, JP |
author_facet | Concannon, J. Moerman, KM Hynes, N. Sultan, S. McGarry, JP |
author_sort | Concannon, J. |
collection | PubMed |
description | The effect of repair techniques on the biomechanics of the aorta is poorly understood, resulting in significant levels of postoperative complications for patients worldwide. This study presents a computational analysis of the influence of Nitinol-based devices on the biomechanical performance of a healthy patient-specific human aorta. Simulations reveal that Nitinol stent-grafts stretch the artery wall so that collagen is stretched to a straightened high-stiffness configuration. The high-compliance regime (HCR) associated with low diastolic lumen pressure is eliminated, and the artery operates in a low-compliance regime (LCR) throughout the entire cardiac cycle. The slope of the lumen pressure–area curve for the LCR post-implantation is almost identical to that of the native vessel during systole. This negligible change from the native LCR slope occurs because the stent-graft increases its diameter from the crimped configuration during deployment so that it reaches a low-stiffness unloading plateau. The effective radial stiffness of the implant along this unloading plateau is negligible compared to the stiffness of the artery wall. Provided the Nitinol device unloads sufficiently during deployment to the unloading plateau, the degree of oversizing has a negligible effect on the pressure–area response of the vessel, as each device exerts approximately the same radial force, the slope of which is negligible compared to the LCR slope of the native artery. We show that 10% oversizing based on the observed diastolic diameter in the mid descending thoracic aorta results in a complete loss of contact between the device and the wall during systole, which could lead to an endoleak and stent migration. 20% oversizing reaches the Dacron enforced area limit (DEAL) during the pulse pressure and results in an effective zero-compliance in the later portion of systole. |
format | Online Article Text |
id | pubmed-8595172 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-85951722021-11-24 Influence of shape-memory stent grafts on local aortic compliance Concannon, J. Moerman, KM Hynes, N. Sultan, S. McGarry, JP Biomech Model Mechanobiol Original Paper The effect of repair techniques on the biomechanics of the aorta is poorly understood, resulting in significant levels of postoperative complications for patients worldwide. This study presents a computational analysis of the influence of Nitinol-based devices on the biomechanical performance of a healthy patient-specific human aorta. Simulations reveal that Nitinol stent-grafts stretch the artery wall so that collagen is stretched to a straightened high-stiffness configuration. The high-compliance regime (HCR) associated with low diastolic lumen pressure is eliminated, and the artery operates in a low-compliance regime (LCR) throughout the entire cardiac cycle. The slope of the lumen pressure–area curve for the LCR post-implantation is almost identical to that of the native vessel during systole. This negligible change from the native LCR slope occurs because the stent-graft increases its diameter from the crimped configuration during deployment so that it reaches a low-stiffness unloading plateau. The effective radial stiffness of the implant along this unloading plateau is negligible compared to the stiffness of the artery wall. Provided the Nitinol device unloads sufficiently during deployment to the unloading plateau, the degree of oversizing has a negligible effect on the pressure–area response of the vessel, as each device exerts approximately the same radial force, the slope of which is negligible compared to the LCR slope of the native artery. We show that 10% oversizing based on the observed diastolic diameter in the mid descending thoracic aorta results in a complete loss of contact between the device and the wall during systole, which could lead to an endoleak and stent migration. 20% oversizing reaches the Dacron enforced area limit (DEAL) during the pulse pressure and results in an effective zero-compliance in the later portion of systole. Springer Berlin Heidelberg 2021-09-19 2021 /pmc/articles/PMC8595172/ /pubmed/34541627 http://dx.doi.org/10.1007/s10237-021-01514-9 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Paper Concannon, J. Moerman, KM Hynes, N. Sultan, S. McGarry, JP Influence of shape-memory stent grafts on local aortic compliance |
title | Influence of shape-memory stent grafts on local aortic compliance |
title_full | Influence of shape-memory stent grafts on local aortic compliance |
title_fullStr | Influence of shape-memory stent grafts on local aortic compliance |
title_full_unstemmed | Influence of shape-memory stent grafts on local aortic compliance |
title_short | Influence of shape-memory stent grafts on local aortic compliance |
title_sort | influence of shape-memory stent grafts on local aortic compliance |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8595172/ https://www.ncbi.nlm.nih.gov/pubmed/34541627 http://dx.doi.org/10.1007/s10237-021-01514-9 |
work_keys_str_mv | AT concannonj influenceofshapememorystentgraftsonlocalaorticcompliance AT moermankm influenceofshapememorystentgraftsonlocalaorticcompliance AT hynesn influenceofshapememorystentgraftsonlocalaorticcompliance AT sultans influenceofshapememorystentgraftsonlocalaorticcompliance AT mcgarryjp influenceofshapememorystentgraftsonlocalaorticcompliance |