Cargando…
Regularized joint water–fat separation with B(0) map estimation in image space for 2D‐navigated interleaved EPI based diffusion MRI
PURPOSE: To develop a new water–fat separation and B(0) estimation algorithm to effectively suppress the multiple resonances of fat signal in EPI. This is especially relevant for DWI where fat is often a confounding factor. METHODS: Water–fat separation based on chemical‐shift encoding enables robus...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8596522/ https://www.ncbi.nlm.nih.gov/pubmed/34255392 http://dx.doi.org/10.1002/mrm.28919 |
_version_ | 1784600396669386752 |
---|---|
author | Dong, Yiming Koolstra, Kirsten Riedel, Malte van Osch, Matthias J. P. Börnert, Peter |
author_facet | Dong, Yiming Koolstra, Kirsten Riedel, Malte van Osch, Matthias J. P. Börnert, Peter |
author_sort | Dong, Yiming |
collection | PubMed |
description | PURPOSE: To develop a new water–fat separation and B(0) estimation algorithm to effectively suppress the multiple resonances of fat signal in EPI. This is especially relevant for DWI where fat is often a confounding factor. METHODS: Water–fat separation based on chemical‐shift encoding enables robust fat suppression in routine MRI. However, for EPI the different chemical‐shift displacements of the multiple fat resonances along the phase‐encoding direction can be problematic for conventional separation algorithms. This work proposes a suitable model approximation for EPI under B(0) and fat off‐resonance effects, providing a feasible multi‐peak water–fat separation algorithm. Simulations were performed to validate the algorithm. In vivo validation was performed in 6 volunteers, acquiring spin‐echo EPI images in the leg (B(0) homogeneous) and head‐neck (B(0) inhomogeneous) regions, using a TE‐shifted interleaved EPI sequence with/without diffusion sensitization. The results are numerically and statistically compared with voxel‐independent water–fat separation and fat saturation techniques to demonstrate the performance of the proposed algorithm. RESULTS: The reference separation algorithm without the proposed spatial shift correction caused water–fat ambiguities in simulations and in vivo experiments. Some spectrally selective fat saturation approaches also failed to suppress fat in regions with severe B(0) inhomogeneities. The proposed algorithm was able to achieve improved fat suppression for DWI data and ADC maps in the head–neck and leg regions. CONCLUSION: The proposed algorithm shows improved suppression of the multi‐peak fat components in multi‐shot interleaved EPI applications compared to the conventional fat saturation approaches and separation algorithms. |
format | Online Article Text |
id | pubmed-8596522 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-85965222021-11-22 Regularized joint water–fat separation with B(0) map estimation in image space for 2D‐navigated interleaved EPI based diffusion MRI Dong, Yiming Koolstra, Kirsten Riedel, Malte van Osch, Matthias J. P. Börnert, Peter Magn Reson Med Research Articles—Imaging Methodology PURPOSE: To develop a new water–fat separation and B(0) estimation algorithm to effectively suppress the multiple resonances of fat signal in EPI. This is especially relevant for DWI where fat is often a confounding factor. METHODS: Water–fat separation based on chemical‐shift encoding enables robust fat suppression in routine MRI. However, for EPI the different chemical‐shift displacements of the multiple fat resonances along the phase‐encoding direction can be problematic for conventional separation algorithms. This work proposes a suitable model approximation for EPI under B(0) and fat off‐resonance effects, providing a feasible multi‐peak water–fat separation algorithm. Simulations were performed to validate the algorithm. In vivo validation was performed in 6 volunteers, acquiring spin‐echo EPI images in the leg (B(0) homogeneous) and head‐neck (B(0) inhomogeneous) regions, using a TE‐shifted interleaved EPI sequence with/without diffusion sensitization. The results are numerically and statistically compared with voxel‐independent water–fat separation and fat saturation techniques to demonstrate the performance of the proposed algorithm. RESULTS: The reference separation algorithm without the proposed spatial shift correction caused water–fat ambiguities in simulations and in vivo experiments. Some spectrally selective fat saturation approaches also failed to suppress fat in regions with severe B(0) inhomogeneities. The proposed algorithm was able to achieve improved fat suppression for DWI data and ADC maps in the head–neck and leg regions. CONCLUSION: The proposed algorithm shows improved suppression of the multi‐peak fat components in multi‐shot interleaved EPI applications compared to the conventional fat saturation approaches and separation algorithms. John Wiley and Sons Inc. 2021-07-13 2021-12 /pmc/articles/PMC8596522/ /pubmed/34255392 http://dx.doi.org/10.1002/mrm.28919 Text en © 2021 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Research Articles—Imaging Methodology Dong, Yiming Koolstra, Kirsten Riedel, Malte van Osch, Matthias J. P. Börnert, Peter Regularized joint water–fat separation with B(0) map estimation in image space for 2D‐navigated interleaved EPI based diffusion MRI |
title | Regularized joint water–fat separation with B(0) map estimation in image space for 2D‐navigated interleaved EPI based diffusion MRI |
title_full | Regularized joint water–fat separation with B(0) map estimation in image space for 2D‐navigated interleaved EPI based diffusion MRI |
title_fullStr | Regularized joint water–fat separation with B(0) map estimation in image space for 2D‐navigated interleaved EPI based diffusion MRI |
title_full_unstemmed | Regularized joint water–fat separation with B(0) map estimation in image space for 2D‐navigated interleaved EPI based diffusion MRI |
title_short | Regularized joint water–fat separation with B(0) map estimation in image space for 2D‐navigated interleaved EPI based diffusion MRI |
title_sort | regularized joint water–fat separation with b(0) map estimation in image space for 2d‐navigated interleaved epi based diffusion mri |
topic | Research Articles—Imaging Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8596522/ https://www.ncbi.nlm.nih.gov/pubmed/34255392 http://dx.doi.org/10.1002/mrm.28919 |
work_keys_str_mv | AT dongyiming regularizedjointwaterfatseparationwithb0mapestimationinimagespacefor2dnavigatedinterleavedepibaseddiffusionmri AT koolstrakirsten regularizedjointwaterfatseparationwithb0mapestimationinimagespacefor2dnavigatedinterleavedepibaseddiffusionmri AT riedelmalte regularizedjointwaterfatseparationwithb0mapestimationinimagespacefor2dnavigatedinterleavedepibaseddiffusionmri AT vanoschmatthiasjp regularizedjointwaterfatseparationwithb0mapestimationinimagespacefor2dnavigatedinterleavedepibaseddiffusionmri AT bornertpeter regularizedjointwaterfatseparationwithb0mapestimationinimagespacefor2dnavigatedinterleavedepibaseddiffusionmri |