Cargando…
Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI
PURPOSE: To introduce and characterize inexpensive and easily produced 3D‐printed axon‐mimetic diffusion MRI phantoms in terms of pore geometry and diffusion kurtosis imaging metrics. METHODS: Phantoms were 3D‐printed with a composite printing material that, after the dissolution of the polyvinyl al...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8596689/ https://www.ncbi.nlm.nih.gov/pubmed/34196049 http://dx.doi.org/10.1002/mrm.28886 |
_version_ | 1784600441327190016 |
---|---|
author | Mushtaha, Farah N. Kuehn, Tristan K. El‐Deeb, Omar Rohani, Seyed A. Helpard, Luke W. Moore, John Ladak, Hanif Moehring, Amanda Baron, Corey A. Khan, Ali R. |
author_facet | Mushtaha, Farah N. Kuehn, Tristan K. El‐Deeb, Omar Rohani, Seyed A. Helpard, Luke W. Moore, John Ladak, Hanif Moehring, Amanda Baron, Corey A. Khan, Ali R. |
author_sort | Mushtaha, Farah N. |
collection | PubMed |
description | PURPOSE: To introduce and characterize inexpensive and easily produced 3D‐printed axon‐mimetic diffusion MRI phantoms in terms of pore geometry and diffusion kurtosis imaging metrics. METHODS: Phantoms were 3D‐printed with a composite printing material that, after the dissolution of the polyvinyl alcohol, exhibits microscopic fibrous pores. Confocal microscopy and synchrotron phase‐contrast micro‐CT imaging were performed to visualize and assess the pore sizes. Diffusion MRI scans of four identical phantoms and phantoms with varying print parameters in water were performed at 9.4 T. Diffusion kurtosis imaging was fit to both data sets and used to assess the reproducibility between phantoms and effects of print parameters on diffusion kurtosis imaging metrics. Identical scans were performed 25 and 76 days later, to test their stability. RESULTS: Segmentation of pores in three microscopy images yielded a mean, median, and SD of equivalent pore diameters of 7.57 μm, 3.51 μm, and 12.13 μm, respectively. Phantoms had T(1)/T(2) = 2 seconds/180 ms, and those with identical parameters showed a low coefficient of variation (~10%) in mean diffusivity (1.38 × 10(−3) mm(2)/s) and kurtosis (0.52) metrics and radial diffusivity (1.01 × 10(−3) mm(2)/s) and kurtosis (1.13) metrics. Printing temperature and speed had a small effect on diffusion kurtosis imaging metrics (< 16%), whereas infill density had a larger and more variable effect (> 16%). The stability analysis showed small changes over 2.5 months (< 7%). CONCLUSION: Three‐dimension‐printed axon‐mimetic phantoms can mimic the fibrous structure of axon bundles on a microscopic scale, serving as complex, anisotropic diffusion MRI phantoms. |
format | Online Article Text |
id | pubmed-8596689 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-85966892021-11-22 Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI Mushtaha, Farah N. Kuehn, Tristan K. El‐Deeb, Omar Rohani, Seyed A. Helpard, Luke W. Moore, John Ladak, Hanif Moehring, Amanda Baron, Corey A. Khan, Ali R. Magn Reson Med Research Articles—Imaging Methodology PURPOSE: To introduce and characterize inexpensive and easily produced 3D‐printed axon‐mimetic diffusion MRI phantoms in terms of pore geometry and diffusion kurtosis imaging metrics. METHODS: Phantoms were 3D‐printed with a composite printing material that, after the dissolution of the polyvinyl alcohol, exhibits microscopic fibrous pores. Confocal microscopy and synchrotron phase‐contrast micro‐CT imaging were performed to visualize and assess the pore sizes. Diffusion MRI scans of four identical phantoms and phantoms with varying print parameters in water were performed at 9.4 T. Diffusion kurtosis imaging was fit to both data sets and used to assess the reproducibility between phantoms and effects of print parameters on diffusion kurtosis imaging metrics. Identical scans were performed 25 and 76 days later, to test their stability. RESULTS: Segmentation of pores in three microscopy images yielded a mean, median, and SD of equivalent pore diameters of 7.57 μm, 3.51 μm, and 12.13 μm, respectively. Phantoms had T(1)/T(2) = 2 seconds/180 ms, and those with identical parameters showed a low coefficient of variation (~10%) in mean diffusivity (1.38 × 10(−3) mm(2)/s) and kurtosis (0.52) metrics and radial diffusivity (1.01 × 10(−3) mm(2)/s) and kurtosis (1.13) metrics. Printing temperature and speed had a small effect on diffusion kurtosis imaging metrics (< 16%), whereas infill density had a larger and more variable effect (> 16%). The stability analysis showed small changes over 2.5 months (< 7%). CONCLUSION: Three‐dimension‐printed axon‐mimetic phantoms can mimic the fibrous structure of axon bundles on a microscopic scale, serving as complex, anisotropic diffusion MRI phantoms. John Wiley and Sons Inc. 2021-06-30 2021-11 /pmc/articles/PMC8596689/ /pubmed/34196049 http://dx.doi.org/10.1002/mrm.28886 Text en © 2021 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Articles—Imaging Methodology Mushtaha, Farah N. Kuehn, Tristan K. El‐Deeb, Omar Rohani, Seyed A. Helpard, Luke W. Moore, John Ladak, Hanif Moehring, Amanda Baron, Corey A. Khan, Ali R. Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI |
title | Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI |
title_full | Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI |
title_fullStr | Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI |
title_full_unstemmed | Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI |
title_short | Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI |
title_sort | design and characterization of a 3d‐printed axon‐mimetic phantom for diffusion mri |
topic | Research Articles—Imaging Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8596689/ https://www.ncbi.nlm.nih.gov/pubmed/34196049 http://dx.doi.org/10.1002/mrm.28886 |
work_keys_str_mv | AT mushtahafarahn designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri AT kuehntristank designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri AT eldeebomar designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri AT rohaniseyeda designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri AT helpardlukew designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri AT moorejohn designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri AT ladakhanif designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri AT moehringamanda designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri AT baroncoreya designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri AT khanalir designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri |