Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI

PURPOSE: To introduce and characterize inexpensive and easily produced 3D‐printed axon‐mimetic diffusion MRI phantoms in terms of pore geometry and diffusion kurtosis imaging metrics. METHODS: Phantoms were 3D‐printed with a composite printing material that, after the dissolution of the polyvinyl al...

Descripción completa

Detalles Bibliográficos
Autores principales: Mushtaha, Farah N., Kuehn, Tristan K., El‐Deeb, Omar, Rohani, Seyed A., Helpard, Luke W., Moore, John, Ladak, Hanif, Moehring, Amanda, Baron, Corey A., Khan, Ali R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8596689/
https://www.ncbi.nlm.nih.gov/pubmed/34196049
http://dx.doi.org/10.1002/mrm.28886
_version_ 1784600441327190016
author Mushtaha, Farah N.
Kuehn, Tristan K.
El‐Deeb, Omar
Rohani, Seyed A.
Helpard, Luke W.
Moore, John
Ladak, Hanif
Moehring, Amanda
Baron, Corey A.
Khan, Ali R.
author_facet Mushtaha, Farah N.
Kuehn, Tristan K.
El‐Deeb, Omar
Rohani, Seyed A.
Helpard, Luke W.
Moore, John
Ladak, Hanif
Moehring, Amanda
Baron, Corey A.
Khan, Ali R.
author_sort Mushtaha, Farah N.
collection PubMed
description PURPOSE: To introduce and characterize inexpensive and easily produced 3D‐printed axon‐mimetic diffusion MRI phantoms in terms of pore geometry and diffusion kurtosis imaging metrics. METHODS: Phantoms were 3D‐printed with a composite printing material that, after the dissolution of the polyvinyl alcohol, exhibits microscopic fibrous pores. Confocal microscopy and synchrotron phase‐contrast micro‐CT imaging were performed to visualize and assess the pore sizes. Diffusion MRI scans of four identical phantoms and phantoms with varying print parameters in water were performed at 9.4 T. Diffusion kurtosis imaging was fit to both data sets and used to assess the reproducibility between phantoms and effects of print parameters on diffusion kurtosis imaging metrics. Identical scans were performed 25 and 76 days later, to test their stability. RESULTS: Segmentation of pores in three microscopy images yielded a mean, median, and SD of equivalent pore diameters of 7.57 μm, 3.51 μm, and 12.13 μm, respectively. Phantoms had T(1)/T(2) = 2 seconds/180 ms, and those with identical parameters showed a low coefficient of variation (~10%) in mean diffusivity (1.38 × 10(−3) mm(2)/s) and kurtosis (0.52) metrics and radial diffusivity (1.01 × 10(−3) mm(2)/s) and kurtosis (1.13) metrics. Printing temperature and speed had a small effect on diffusion kurtosis imaging metrics (< 16%), whereas infill density had a larger and more variable effect (> 16%). The stability analysis showed small changes over 2.5 months (< 7%). CONCLUSION: Three‐dimension‐printed axon‐mimetic phantoms can mimic the fibrous structure of axon bundles on a microscopic scale, serving as complex, anisotropic diffusion MRI phantoms.
format Online
Article
Text
id pubmed-8596689
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-85966892021-11-22 Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI Mushtaha, Farah N. Kuehn, Tristan K. El‐Deeb, Omar Rohani, Seyed A. Helpard, Luke W. Moore, John Ladak, Hanif Moehring, Amanda Baron, Corey A. Khan, Ali R. Magn Reson Med Research Articles—Imaging Methodology PURPOSE: To introduce and characterize inexpensive and easily produced 3D‐printed axon‐mimetic diffusion MRI phantoms in terms of pore geometry and diffusion kurtosis imaging metrics. METHODS: Phantoms were 3D‐printed with a composite printing material that, after the dissolution of the polyvinyl alcohol, exhibits microscopic fibrous pores. Confocal microscopy and synchrotron phase‐contrast micro‐CT imaging were performed to visualize and assess the pore sizes. Diffusion MRI scans of four identical phantoms and phantoms with varying print parameters in water were performed at 9.4 T. Diffusion kurtosis imaging was fit to both data sets and used to assess the reproducibility between phantoms and effects of print parameters on diffusion kurtosis imaging metrics. Identical scans were performed 25 and 76 days later, to test their stability. RESULTS: Segmentation of pores in three microscopy images yielded a mean, median, and SD of equivalent pore diameters of 7.57 μm, 3.51 μm, and 12.13 μm, respectively. Phantoms had T(1)/T(2) = 2 seconds/180 ms, and those with identical parameters showed a low coefficient of variation (~10%) in mean diffusivity (1.38 × 10(−3) mm(2)/s) and kurtosis (0.52) metrics and radial diffusivity (1.01 × 10(−3) mm(2)/s) and kurtosis (1.13) metrics. Printing temperature and speed had a small effect on diffusion kurtosis imaging metrics (< 16%), whereas infill density had a larger and more variable effect (> 16%). The stability analysis showed small changes over 2.5 months (< 7%). CONCLUSION: Three‐dimension‐printed axon‐mimetic phantoms can mimic the fibrous structure of axon bundles on a microscopic scale, serving as complex, anisotropic diffusion MRI phantoms. John Wiley and Sons Inc. 2021-06-30 2021-11 /pmc/articles/PMC8596689/ /pubmed/34196049 http://dx.doi.org/10.1002/mrm.28886 Text en © 2021 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles—Imaging Methodology
Mushtaha, Farah N.
Kuehn, Tristan K.
El‐Deeb, Omar
Rohani, Seyed A.
Helpard, Luke W.
Moore, John
Ladak, Hanif
Moehring, Amanda
Baron, Corey A.
Khan, Ali R.
Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI
title Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI
title_full Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI
title_fullStr Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI
title_full_unstemmed Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI
title_short Design and characterization of a 3D‐printed axon‐mimetic phantom for diffusion MRI
title_sort design and characterization of a 3d‐printed axon‐mimetic phantom for diffusion mri
topic Research Articles—Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8596689/
https://www.ncbi.nlm.nih.gov/pubmed/34196049
http://dx.doi.org/10.1002/mrm.28886
work_keys_str_mv AT mushtahafarahn designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri
AT kuehntristank designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri
AT eldeebomar designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri
AT rohaniseyeda designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri
AT helpardlukew designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri
AT moorejohn designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri
AT ladakhanif designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri
AT moehringamanda designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri
AT baroncoreya designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri
AT khanalir designandcharacterizationofa3dprintedaxonmimeticphantomfordiffusionmri