Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study

BACKGROUND: Thermal imaging has been used as a clinical follow-up technique in several medical specialties. PURPOSE: The aim of this study was to investigate the feasibility of using medical thermography in the diagnosis and follow-up assessment of a severe orthopedic trauma that requires the use of...

Descripción completa

Detalles Bibliográficos
Autores principales: auf der Strasse, Wally, Campos, Daniel Prado, Mendonça, Celso Júnio Aguiar, Soni, Jamil Faissal, Mendes, Joaquim, Nohama, Percy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8598209/
https://www.ncbi.nlm.nih.gov/pubmed/34803384
http://dx.doi.org/10.2147/JMDH.S330094
_version_ 1784600767485706240
author auf der Strasse, Wally
Campos, Daniel Prado
Mendonça, Celso Júnio Aguiar
Soni, Jamil Faissal
Mendes, Joaquim
Nohama, Percy
author_facet auf der Strasse, Wally
Campos, Daniel Prado
Mendonça, Celso Júnio Aguiar
Soni, Jamil Faissal
Mendes, Joaquim
Nohama, Percy
author_sort auf der Strasse, Wally
collection PubMed
description BACKGROUND: Thermal imaging has been used as a clinical follow-up technique in several medical specialties. PURPOSE: The aim of this study was to investigate the feasibility of using medical thermography in the diagnosis and follow-up assessment of a severe orthopedic trauma that requires the use of an external circular fixator. PATIENTS AND METHODS: Twenty clinical follow-ups of thermal imaging correlated with X-ray images were performed in a male volunteer, diagnosed with bone nonunion, during 11 months of treatment, in the hospital trauma and reconstruction department. Data were acquired in the regions of interest of the proximal tibia, diaphysis and distal, with a Flir T530 medical grade infrared camera from Flir Systems(®), and the data processed by the Matlab(®) 2019 custom made software. RESULTS: Statistical analysis was performed by Wilcoxon signed-rank test. The results showed a median temperature of 22.2°C, and thus some periods of interruption in the healing process between the third and twentieth clinical follow-up, and a significant increase of the temperature to 34.6°C synchronous with a diagnosis of bone infection by the eleventh clinical follow-up. The thermal images acquired during the 20 clinical follow-ups allow a correlation with the data from the X-ray exams and also with the contralateral limb of the evaluated patient, showing thermal alterations greater than 0.3°C, which are significant of physiological abnormality. CONCLUSION: The thermography exam can be a useful tool for applying on the follow-up of patients after trauma or bone fracture. The results showed important physiological data related to the vascularization necessary for bone repairing, being therefore a good indicator of the healing process. In addition, as infrared thermography does not use ionizing radiation, it can be used countlessly, in complement to the traditional X-ray exams that focus on anatomical data analysis.
format Online
Article
Text
id pubmed-8598209
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-85982092021-11-19 Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study auf der Strasse, Wally Campos, Daniel Prado Mendonça, Celso Júnio Aguiar Soni, Jamil Faissal Mendes, Joaquim Nohama, Percy J Multidiscip Healthc Case Report BACKGROUND: Thermal imaging has been used as a clinical follow-up technique in several medical specialties. PURPOSE: The aim of this study was to investigate the feasibility of using medical thermography in the diagnosis and follow-up assessment of a severe orthopedic trauma that requires the use of an external circular fixator. PATIENTS AND METHODS: Twenty clinical follow-ups of thermal imaging correlated with X-ray images were performed in a male volunteer, diagnosed with bone nonunion, during 11 months of treatment, in the hospital trauma and reconstruction department. Data were acquired in the regions of interest of the proximal tibia, diaphysis and distal, with a Flir T530 medical grade infrared camera from Flir Systems(®), and the data processed by the Matlab(®) 2019 custom made software. RESULTS: Statistical analysis was performed by Wilcoxon signed-rank test. The results showed a median temperature of 22.2°C, and thus some periods of interruption in the healing process between the third and twentieth clinical follow-up, and a significant increase of the temperature to 34.6°C synchronous with a diagnosis of bone infection by the eleventh clinical follow-up. The thermal images acquired during the 20 clinical follow-ups allow a correlation with the data from the X-ray exams and also with the contralateral limb of the evaluated patient, showing thermal alterations greater than 0.3°C, which are significant of physiological abnormality. CONCLUSION: The thermography exam can be a useful tool for applying on the follow-up of patients after trauma or bone fracture. The results showed important physiological data related to the vascularization necessary for bone repairing, being therefore a good indicator of the healing process. In addition, as infrared thermography does not use ionizing radiation, it can be used countlessly, in complement to the traditional X-ray exams that focus on anatomical data analysis. Dove 2021-11-13 /pmc/articles/PMC8598209/ /pubmed/34803384 http://dx.doi.org/10.2147/JMDH.S330094 Text en © 2021 auf der Strasse et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Case Report
auf der Strasse, Wally
Campos, Daniel Prado
Mendonça, Celso Júnio Aguiar
Soni, Jamil Faissal
Mendes, Joaquim
Nohama, Percy
Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study
title Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study
title_full Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study
title_fullStr Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study
title_full_unstemmed Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study
title_short Evaluation of Tibia Bone Healing by Infrared Thermography: A Case Study
title_sort evaluation of tibia bone healing by infrared thermography: a case study
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8598209/
https://www.ncbi.nlm.nih.gov/pubmed/34803384
http://dx.doi.org/10.2147/JMDH.S330094
work_keys_str_mv AT aufderstrassewally evaluationoftibiabonehealingbyinfraredthermographyacasestudy
AT camposdanielprado evaluationoftibiabonehealingbyinfraredthermographyacasestudy
AT mendoncacelsojunioaguiar evaluationoftibiabonehealingbyinfraredthermographyacasestudy
AT sonijamilfaissal evaluationoftibiabonehealingbyinfraredthermographyacasestudy
AT mendesjoaquim evaluationoftibiabonehealingbyinfraredthermographyacasestudy
AT nohamapercy evaluationoftibiabonehealingbyinfraredthermographyacasestudy