Cargando…

Complex Regional Pain Syndrome with Aortic Distress after Thoracic Endovascular Aortic Repair and False Lumen Exclusion with “Candy Plug” Technique

A 41-year-old male presented for pain treated with oxycodone. A zone-2 thoracic endovascular aortic repair with distal PETTICOAT (provisional extension to induce complete attachment) for complicated Type-IIIB aortic dissection was performed 18 months before. Repeated hospitalizations did not show an...

Descripción completa

Detalles Bibliográficos
Autores principales: Tolva, Valerio S., Kahlberg, Andrea, Bertoglio, Luca, Trimarchi, Santi, Miloro, Riccardo, Casana, Renato, Chiesa, Roberto
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical Publishers, Inc. 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8598316/
https://www.ncbi.nlm.nih.gov/pubmed/34644804
http://dx.doi.org/10.1055/s-0041-1730007
_version_ 1784600797567254528
author Tolva, Valerio S.
Kahlberg, Andrea
Bertoglio, Luca
Trimarchi, Santi
Miloro, Riccardo
Casana, Renato
Chiesa, Roberto
author_facet Tolva, Valerio S.
Kahlberg, Andrea
Bertoglio, Luca
Trimarchi, Santi
Miloro, Riccardo
Casana, Renato
Chiesa, Roberto
author_sort Tolva, Valerio S.
collection PubMed
description A 41-year-old male presented for pain treated with oxycodone. A zone-2 thoracic endovascular aortic repair with distal PETTICOAT (provisional extension to induce complete attachment) for complicated Type-IIIB aortic dissection was performed 18 months before. Repeated hospitalizations did not show any issues to justify the recurrent pain. The aortic nature of the pain was suspected considering the plug as a pain trigger. Through a left thoracoabdominal incision in the eighth intercostal space, the candy plug was removed. Pain diminished after thoracoabdominal surgery steadily.
format Online
Article
Text
id pubmed-8598316
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Thieme Medical Publishers, Inc.
record_format MEDLINE/PubMed
spelling pubmed-85983162021-11-18 Complex Regional Pain Syndrome with Aortic Distress after Thoracic Endovascular Aortic Repair and False Lumen Exclusion with “Candy Plug” Technique Tolva, Valerio S. Kahlberg, Andrea Bertoglio, Luca Trimarchi, Santi Miloro, Riccardo Casana, Renato Chiesa, Roberto Aorta (Stamford) A 41-year-old male presented for pain treated with oxycodone. A zone-2 thoracic endovascular aortic repair with distal PETTICOAT (provisional extension to induce complete attachment) for complicated Type-IIIB aortic dissection was performed 18 months before. Repeated hospitalizations did not show any issues to justify the recurrent pain. The aortic nature of the pain was suspected considering the plug as a pain trigger. Through a left thoracoabdominal incision in the eighth intercostal space, the candy plug was removed. Pain diminished after thoracoabdominal surgery steadily. Thieme Medical Publishers, Inc. 2021-10-13 /pmc/articles/PMC8598316/ /pubmed/34644804 http://dx.doi.org/10.1055/s-0041-1730007 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. ( https://creativecommons.org/licenses/by/4.0/ ) https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Tolva, Valerio S.
Kahlberg, Andrea
Bertoglio, Luca
Trimarchi, Santi
Miloro, Riccardo
Casana, Renato
Chiesa, Roberto
Complex Regional Pain Syndrome with Aortic Distress after Thoracic Endovascular Aortic Repair and False Lumen Exclusion with “Candy Plug” Technique
title Complex Regional Pain Syndrome with Aortic Distress after Thoracic Endovascular Aortic Repair and False Lumen Exclusion with “Candy Plug” Technique
title_full Complex Regional Pain Syndrome with Aortic Distress after Thoracic Endovascular Aortic Repair and False Lumen Exclusion with “Candy Plug” Technique
title_fullStr Complex Regional Pain Syndrome with Aortic Distress after Thoracic Endovascular Aortic Repair and False Lumen Exclusion with “Candy Plug” Technique
title_full_unstemmed Complex Regional Pain Syndrome with Aortic Distress after Thoracic Endovascular Aortic Repair and False Lumen Exclusion with “Candy Plug” Technique
title_short Complex Regional Pain Syndrome with Aortic Distress after Thoracic Endovascular Aortic Repair and False Lumen Exclusion with “Candy Plug” Technique
title_sort complex regional pain syndrome with aortic distress after thoracic endovascular aortic repair and false lumen exclusion with “candy plug” technique
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8598316/
https://www.ncbi.nlm.nih.gov/pubmed/34644804
http://dx.doi.org/10.1055/s-0041-1730007
work_keys_str_mv AT tolvavalerios complexregionalpainsyndromewithaorticdistressafterthoracicendovascularaorticrepairandfalselumenexclusionwithcandyplugtechnique
AT kahlbergandrea complexregionalpainsyndromewithaorticdistressafterthoracicendovascularaorticrepairandfalselumenexclusionwithcandyplugtechnique
AT bertoglioluca complexregionalpainsyndromewithaorticdistressafterthoracicendovascularaorticrepairandfalselumenexclusionwithcandyplugtechnique
AT trimarchisanti complexregionalpainsyndromewithaorticdistressafterthoracicendovascularaorticrepairandfalselumenexclusionwithcandyplugtechnique
AT milororiccardo complexregionalpainsyndromewithaorticdistressafterthoracicendovascularaorticrepairandfalselumenexclusionwithcandyplugtechnique
AT casanarenato complexregionalpainsyndromewithaorticdistressafterthoracicendovascularaorticrepairandfalselumenexclusionwithcandyplugtechnique
AT chiesaroberto complexregionalpainsyndromewithaorticdistressafterthoracicendovascularaorticrepairandfalselumenexclusionwithcandyplugtechnique