Complex Regional Pain Syndrome with Aortic Distress after Thoracic Endovascular Aortic Repair and False Lumen Exclusion with “Candy Plug” Technique
A 41-year-old male presented for pain treated with oxycodone. A zone-2 thoracic endovascular aortic repair with distal PETTICOAT (provisional extension to induce complete attachment) for complicated Type-IIIB aortic dissection was performed 18 months before. Repeated hospitalizations did not show an...