Cargando…
Technical report and rare case description—patient-specific spacer made of bone cement for the revision of a PSI-TMJ fossa after screw fracture
Total alloplastic temporomandibular joint replacement (TMJ-TJR) has once again become the focus of therapy for end-stage destroyed joints. Although material quality has increased significantly in terms of service life and wear, problems occur even with patient-specific (PSI) prostheses. Here, mainly...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8599027/ https://www.ncbi.nlm.nih.gov/pubmed/34804477 http://dx.doi.org/10.1093/jscr/rjab466 |
_version_ | 1784600854133735424 |
---|---|
author | Thiem, Daniel G E Al-Nawas, Bilal Kämmerer, Peer W |
author_facet | Thiem, Daniel G E Al-Nawas, Bilal Kämmerer, Peer W |
author_sort | Thiem, Daniel G E |
collection | PubMed |
description | Total alloplastic temporomandibular joint replacement (TMJ-TJR) has once again become the focus of therapy for end-stage destroyed joints. Although material quality has increased significantly in terms of service life and wear, problems occur even with patient-specific (PSI) prostheses. Here, mainly the ramus components are affected and an occurrence of screw loosening or fractures in the area of the fossa of stock joints is rare and has not yet been described for patient-specific (PSI) components. Although very rare, such events pose a great challenge to both practitioners and affected patients, especially in the case of PSI components, not least due to the long time required for new fabrication. The case report shows a non-described screw fracture of a PSI-TMJ fossa and the first description of a temporary revision using a PSI-TMJ fossa made of bone cement. |
format | Online Article Text |
id | pubmed-8599027 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-85990272021-11-18 Technical report and rare case description—patient-specific spacer made of bone cement for the revision of a PSI-TMJ fossa after screw fracture Thiem, Daniel G E Al-Nawas, Bilal Kämmerer, Peer W J Surg Case Rep Case Report Total alloplastic temporomandibular joint replacement (TMJ-TJR) has once again become the focus of therapy for end-stage destroyed joints. Although material quality has increased significantly in terms of service life and wear, problems occur even with patient-specific (PSI) prostheses. Here, mainly the ramus components are affected and an occurrence of screw loosening or fractures in the area of the fossa of stock joints is rare and has not yet been described for patient-specific (PSI) components. Although very rare, such events pose a great challenge to both practitioners and affected patients, especially in the case of PSI components, not least due to the long time required for new fabrication. The case report shows a non-described screw fracture of a PSI-TMJ fossa and the first description of a temporary revision using a PSI-TMJ fossa made of bone cement. Oxford University Press 2021-11-11 /pmc/articles/PMC8599027/ /pubmed/34804477 http://dx.doi.org/10.1093/jscr/rjab466 Text en Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author(s) 2021. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Case Report Thiem, Daniel G E Al-Nawas, Bilal Kämmerer, Peer W Technical report and rare case description—patient-specific spacer made of bone cement for the revision of a PSI-TMJ fossa after screw fracture |
title | Technical report and rare case description—patient-specific spacer made of bone cement for the revision of a PSI-TMJ fossa after screw fracture |
title_full | Technical report and rare case description—patient-specific spacer made of bone cement for the revision of a PSI-TMJ fossa after screw fracture |
title_fullStr | Technical report and rare case description—patient-specific spacer made of bone cement for the revision of a PSI-TMJ fossa after screw fracture |
title_full_unstemmed | Technical report and rare case description—patient-specific spacer made of bone cement for the revision of a PSI-TMJ fossa after screw fracture |
title_short | Technical report and rare case description—patient-specific spacer made of bone cement for the revision of a PSI-TMJ fossa after screw fracture |
title_sort | technical report and rare case description—patient-specific spacer made of bone cement for the revision of a psi-tmj fossa after screw fracture |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8599027/ https://www.ncbi.nlm.nih.gov/pubmed/34804477 http://dx.doi.org/10.1093/jscr/rjab466 |
work_keys_str_mv | AT thiemdanielge technicalreportandrarecasedescriptionpatientspecificspacermadeofbonecementfortherevisionofapsitmjfossaafterscrewfracture AT alnawasbilal technicalreportandrarecasedescriptionpatientspecificspacermadeofbonecementfortherevisionofapsitmjfossaafterscrewfracture AT kammererpeerw technicalreportandrarecasedescriptionpatientspecificspacermadeofbonecementfortherevisionofapsitmjfossaafterscrewfracture |