Cargando…
The Conjunctival Turnover: A Simple and Effective Method for Sclero-Corneal Protection in Pre-Septal Transconjunctival Approach to the Orbital Floor
Transconjunctival approaches have become the mainstay for most surgeons performing orbital wall reconstructions. Adequate care needs to be exercised for the protection of the cornea and sclera during these surgeries as they may involve placement of grafts or implants in situ apart from the routine i...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8599114/ https://www.ncbi.nlm.nih.gov/pubmed/34804731 http://dx.doi.org/10.7759/cureus.18884 |
_version_ | 1784600873463185408 |
---|---|
author | Parameswaran, Anantanarayanan Panneerselvam, Elavenil Jayakumar, Naveenkumar |
author_facet | Parameswaran, Anantanarayanan Panneerselvam, Elavenil Jayakumar, Naveenkumar |
author_sort | Parameswaran, Anantanarayanan |
collection | PubMed |
description | Transconjunctival approaches have become the mainstay for most surgeons performing orbital wall reconstructions. Adequate care needs to be exercised for the protection of the cornea and sclera during these surgeries as they may involve placement of grafts or implants in situ apart from the routine intra-orbital dissections. The authors describe a simple technique of developing a conjunctival turnover flap for sclero-corneal protection in transconjunctival approaches to the orbit. |
format | Online Article Text |
id | pubmed-8599114 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-85991142021-11-20 The Conjunctival Turnover: A Simple and Effective Method for Sclero-Corneal Protection in Pre-Septal Transconjunctival Approach to the Orbital Floor Parameswaran, Anantanarayanan Panneerselvam, Elavenil Jayakumar, Naveenkumar Cureus Ophthalmology Transconjunctival approaches have become the mainstay for most surgeons performing orbital wall reconstructions. Adequate care needs to be exercised for the protection of the cornea and sclera during these surgeries as they may involve placement of grafts or implants in situ apart from the routine intra-orbital dissections. The authors describe a simple technique of developing a conjunctival turnover flap for sclero-corneal protection in transconjunctival approaches to the orbit. Cureus 2021-10-19 /pmc/articles/PMC8599114/ /pubmed/34804731 http://dx.doi.org/10.7759/cureus.18884 Text en Copyright © 2021, Parameswaran et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Ophthalmology Parameswaran, Anantanarayanan Panneerselvam, Elavenil Jayakumar, Naveenkumar The Conjunctival Turnover: A Simple and Effective Method for Sclero-Corneal Protection in Pre-Septal Transconjunctival Approach to the Orbital Floor |
title | The Conjunctival Turnover: A Simple and Effective Method for Sclero-Corneal Protection in Pre-Septal Transconjunctival Approach to the Orbital Floor |
title_full | The Conjunctival Turnover: A Simple and Effective Method for Sclero-Corneal Protection in Pre-Septal Transconjunctival Approach to the Orbital Floor |
title_fullStr | The Conjunctival Turnover: A Simple and Effective Method for Sclero-Corneal Protection in Pre-Septal Transconjunctival Approach to the Orbital Floor |
title_full_unstemmed | The Conjunctival Turnover: A Simple and Effective Method for Sclero-Corneal Protection in Pre-Septal Transconjunctival Approach to the Orbital Floor |
title_short | The Conjunctival Turnover: A Simple and Effective Method for Sclero-Corneal Protection in Pre-Septal Transconjunctival Approach to the Orbital Floor |
title_sort | conjunctival turnover: a simple and effective method for sclero-corneal protection in pre-septal transconjunctival approach to the orbital floor |
topic | Ophthalmology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8599114/ https://www.ncbi.nlm.nih.gov/pubmed/34804731 http://dx.doi.org/10.7759/cureus.18884 |
work_keys_str_mv | AT parameswarananantanarayanan theconjunctivalturnoverasimpleandeffectivemethodforsclerocornealprotectioninpreseptaltransconjunctivalapproachtotheorbitalfloor AT panneerselvamelavenil theconjunctivalturnoverasimpleandeffectivemethodforsclerocornealprotectioninpreseptaltransconjunctivalapproachtotheorbitalfloor AT jayakumarnaveenkumar theconjunctivalturnoverasimpleandeffectivemethodforsclerocornealprotectioninpreseptaltransconjunctivalapproachtotheorbitalfloor AT parameswarananantanarayanan conjunctivalturnoverasimpleandeffectivemethodforsclerocornealprotectioninpreseptaltransconjunctivalapproachtotheorbitalfloor AT panneerselvamelavenil conjunctivalturnoverasimpleandeffectivemethodforsclerocornealprotectioninpreseptaltransconjunctivalapproachtotheorbitalfloor AT jayakumarnaveenkumar conjunctivalturnoverasimpleandeffectivemethodforsclerocornealprotectioninpreseptaltransconjunctivalapproachtotheorbitalfloor |