Cargando…
Identification of Flow-Limiting Coronary Stenosis With PCS: A New Cost-Effective Index Derived From the Product of Corrected TIMI Frame Count and Percent Diameter Stenosis
Background: Identifying functional coronary stenosis with simple and cost-effective methods during invasive coronary angiography is still challenging. Corrected TIMI frame count (CTFC) is considered to be the frame count velocity of coronary blood flow. We aimed to propose a simple and cost-effectiv...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8600119/ https://www.ncbi.nlm.nih.gov/pubmed/34805299 http://dx.doi.org/10.3389/fcvm.2021.718935 |
_version_ | 1784601082357350400 |
---|---|
author | Li, Xinhao Lyu, Lijuan Yang, Wei Pan, Jichen Dong, Mei Zhang, Mei Zhang, Pengfei |
author_facet | Li, Xinhao Lyu, Lijuan Yang, Wei Pan, Jichen Dong, Mei Zhang, Mei Zhang, Pengfei |
author_sort | Li, Xinhao |
collection | PubMed |
description | Background: Identifying functional coronary stenosis with simple and cost-effective methods during invasive coronary angiography is still challenging. Corrected TIMI frame count (CTFC) is considered to be the frame count velocity of coronary blood flow. We aimed to propose a simple and cost-effective index based on CTFC and percent diameter stenosis (DS) to identify flow-limiting coronary stenosis. For this, a new index was put forward as the product of CTFC and DS (PCS). PCS can be regarded as the loss of coronary blood flow due to diameter stenosis. Methods: DS, CTFC, PCS, and Fractional flow reserve (FFR) of 111 vessels in 84 patients with suspected coronary heart disease were measured. FFR ≤0.80 was defined as flow-limiting. Models involving CTFC, DS, and PCS were developed. Logistic regression was performed to evaluate the values on diagnosing flow-limiting stenosis. Results: Vessels with flow-limiting coronary stenosis exhibited higher CTFC values than those without (28.56 vs. 21.64). The performance including the AUC (0.887), sensitivity (87.8%), and Youden index (0.678) for detecting flow-limiting stenosis was improved by adding the CTFC to the DS, while PCS had the largest positive predictive value (PPV) and diagnostic accuracy (DA) being 72.0 and 82.9%, respectively. For vessels with ≥50% lesions, PCS still had the best DA (80.9%), specificity (85.9%), and PPV (72.9%). At the same stenosis severity level, the AUC, Youden index and, DA of PCS were higher than those of CTFC. Conclusions: PCS is simple and accurate to identify flow-limiting coronary stenosis, especially at vessels with moderate to severe stenosis. |
format | Online Article Text |
id | pubmed-8600119 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-86001192021-11-19 Identification of Flow-Limiting Coronary Stenosis With PCS: A New Cost-Effective Index Derived From the Product of Corrected TIMI Frame Count and Percent Diameter Stenosis Li, Xinhao Lyu, Lijuan Yang, Wei Pan, Jichen Dong, Mei Zhang, Mei Zhang, Pengfei Front Cardiovasc Med Cardiovascular Medicine Background: Identifying functional coronary stenosis with simple and cost-effective methods during invasive coronary angiography is still challenging. Corrected TIMI frame count (CTFC) is considered to be the frame count velocity of coronary blood flow. We aimed to propose a simple and cost-effective index based on CTFC and percent diameter stenosis (DS) to identify flow-limiting coronary stenosis. For this, a new index was put forward as the product of CTFC and DS (PCS). PCS can be regarded as the loss of coronary blood flow due to diameter stenosis. Methods: DS, CTFC, PCS, and Fractional flow reserve (FFR) of 111 vessels in 84 patients with suspected coronary heart disease were measured. FFR ≤0.80 was defined as flow-limiting. Models involving CTFC, DS, and PCS were developed. Logistic regression was performed to evaluate the values on diagnosing flow-limiting stenosis. Results: Vessels with flow-limiting coronary stenosis exhibited higher CTFC values than those without (28.56 vs. 21.64). The performance including the AUC (0.887), sensitivity (87.8%), and Youden index (0.678) for detecting flow-limiting stenosis was improved by adding the CTFC to the DS, while PCS had the largest positive predictive value (PPV) and diagnostic accuracy (DA) being 72.0 and 82.9%, respectively. For vessels with ≥50% lesions, PCS still had the best DA (80.9%), specificity (85.9%), and PPV (72.9%). At the same stenosis severity level, the AUC, Youden index and, DA of PCS were higher than those of CTFC. Conclusions: PCS is simple and accurate to identify flow-limiting coronary stenosis, especially at vessels with moderate to severe stenosis. Frontiers Media S.A. 2021-11-04 /pmc/articles/PMC8600119/ /pubmed/34805299 http://dx.doi.org/10.3389/fcvm.2021.718935 Text en Copyright © 2021 Li, Lyu, Yang, Pan, Dong, Zhang and Zhang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Cardiovascular Medicine Li, Xinhao Lyu, Lijuan Yang, Wei Pan, Jichen Dong, Mei Zhang, Mei Zhang, Pengfei Identification of Flow-Limiting Coronary Stenosis With PCS: A New Cost-Effective Index Derived From the Product of Corrected TIMI Frame Count and Percent Diameter Stenosis |
title | Identification of Flow-Limiting Coronary Stenosis With PCS: A New Cost-Effective Index Derived From the Product of Corrected TIMI Frame Count and Percent Diameter Stenosis |
title_full | Identification of Flow-Limiting Coronary Stenosis With PCS: A New Cost-Effective Index Derived From the Product of Corrected TIMI Frame Count and Percent Diameter Stenosis |
title_fullStr | Identification of Flow-Limiting Coronary Stenosis With PCS: A New Cost-Effective Index Derived From the Product of Corrected TIMI Frame Count and Percent Diameter Stenosis |
title_full_unstemmed | Identification of Flow-Limiting Coronary Stenosis With PCS: A New Cost-Effective Index Derived From the Product of Corrected TIMI Frame Count and Percent Diameter Stenosis |
title_short | Identification of Flow-Limiting Coronary Stenosis With PCS: A New Cost-Effective Index Derived From the Product of Corrected TIMI Frame Count and Percent Diameter Stenosis |
title_sort | identification of flow-limiting coronary stenosis with pcs: a new cost-effective index derived from the product of corrected timi frame count and percent diameter stenosis |
topic | Cardiovascular Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8600119/ https://www.ncbi.nlm.nih.gov/pubmed/34805299 http://dx.doi.org/10.3389/fcvm.2021.718935 |
work_keys_str_mv | AT lixinhao identificationofflowlimitingcoronarystenosiswithpcsanewcosteffectiveindexderivedfromtheproductofcorrectedtimiframecountandpercentdiameterstenosis AT lyulijuan identificationofflowlimitingcoronarystenosiswithpcsanewcosteffectiveindexderivedfromtheproductofcorrectedtimiframecountandpercentdiameterstenosis AT yangwei identificationofflowlimitingcoronarystenosiswithpcsanewcosteffectiveindexderivedfromtheproductofcorrectedtimiframecountandpercentdiameterstenosis AT panjichen identificationofflowlimitingcoronarystenosiswithpcsanewcosteffectiveindexderivedfromtheproductofcorrectedtimiframecountandpercentdiameterstenosis AT dongmei identificationofflowlimitingcoronarystenosiswithpcsanewcosteffectiveindexderivedfromtheproductofcorrectedtimiframecountandpercentdiameterstenosis AT zhangmei identificationofflowlimitingcoronarystenosiswithpcsanewcosteffectiveindexderivedfromtheproductofcorrectedtimiframecountandpercentdiameterstenosis AT zhangpengfei identificationofflowlimitingcoronarystenosiswithpcsanewcosteffectiveindexderivedfromtheproductofcorrectedtimiframecountandpercentdiameterstenosis |