Cargando…

A high sensitivity LC-MS/MS method for measurement of 3-methoxytyramine in plasma and associations between 3-methoxytyramine, metanephrines, and dopamine

INTRODUCTION: Diagnosis of pheochromocytoma and paraganglioma (PPGL) is aided by the measurement of metanephrine (MN) and normetanephrine (NMN). Research suggests that 3-methoxytyramine (3MT), a dopamine (DA) metabolite, may serve as a biomarker of metastasis in patients with paraganglioma. Consider...

Descripción completa

Detalles Bibliográficos
Autores principales: Smy, Laura, Kushnir, Mark M., Frank, Elizabeth L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8601001/
https://www.ncbi.nlm.nih.gov/pubmed/34820673
http://dx.doi.org/10.1016/j.jmsacl.2021.08.001
_version_ 1784601260409749504
author Smy, Laura
Kushnir, Mark M.
Frank, Elizabeth L.
author_facet Smy, Laura
Kushnir, Mark M.
Frank, Elizabeth L.
author_sort Smy, Laura
collection PubMed
description INTRODUCTION: Diagnosis of pheochromocytoma and paraganglioma (PPGL) is aided by the measurement of metanephrine (MN) and normetanephrine (NMN). Research suggests that 3-methoxytyramine (3MT), a dopamine (DA) metabolite, may serve as a biomarker of metastasis in patients with paraganglioma. Considering the very low endogenous plasma 3MT concentrations (<0.1 nM), highly sensitive and specific methods for 3MT are needed. METHODS: We developed a simple method for measurement of 3MT. Sample preparation was performed using solid phase micro-extraction with the eluates injected directly onto the LC-MS/MS. Data acquisition was performed in multiple reaction monitoring mode with an instrumental analysis time of 3 min per sample. We evaluated the method’s performance and analyzed samples from healthy individuals and pathological specimens. RESULTS: The limit of quantitation and upper limit of linearity were 0.03 nM and 20 nM, respectively. The intra-/inter-day imprecision for pooled plasma samples at concentrations of 0.04 nM, 0.2 nM, and 2 nM was 10.7%/18.3%, 4.5%/8.9%, and 3.1%/0.9%, respectively. Among samples with MN, NMN, or both MN and NMN above the reference intervals (RIs), 0%, 16% and 46%, respectively, showed 3MT greater than the proposed upper RI value of 0.1 nM; 12% of samples with DA above the RI had 3MT above 0.1 nM. CONCLUSIONS: The developed method allowed accurate quantitation of 3MT in patient samples and would provide valuable information to clinicians diagnosing or monitoring patients with PPGL. High 3MT concentrations in patient samples with MN and NMN within the respective RIs may alert clinicians of the possibility of a DA-producing tumor.
format Online
Article
Text
id pubmed-8601001
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-86010012021-11-23 A high sensitivity LC-MS/MS method for measurement of 3-methoxytyramine in plasma and associations between 3-methoxytyramine, metanephrines, and dopamine Smy, Laura Kushnir, Mark M. Frank, Elizabeth L. J Mass Spectrom Adv Clin Lab Regular Article INTRODUCTION: Diagnosis of pheochromocytoma and paraganglioma (PPGL) is aided by the measurement of metanephrine (MN) and normetanephrine (NMN). Research suggests that 3-methoxytyramine (3MT), a dopamine (DA) metabolite, may serve as a biomarker of metastasis in patients with paraganglioma. Considering the very low endogenous plasma 3MT concentrations (<0.1 nM), highly sensitive and specific methods for 3MT are needed. METHODS: We developed a simple method for measurement of 3MT. Sample preparation was performed using solid phase micro-extraction with the eluates injected directly onto the LC-MS/MS. Data acquisition was performed in multiple reaction monitoring mode with an instrumental analysis time of 3 min per sample. We evaluated the method’s performance and analyzed samples from healthy individuals and pathological specimens. RESULTS: The limit of quantitation and upper limit of linearity were 0.03 nM and 20 nM, respectively. The intra-/inter-day imprecision for pooled plasma samples at concentrations of 0.04 nM, 0.2 nM, and 2 nM was 10.7%/18.3%, 4.5%/8.9%, and 3.1%/0.9%, respectively. Among samples with MN, NMN, or both MN and NMN above the reference intervals (RIs), 0%, 16% and 46%, respectively, showed 3MT greater than the proposed upper RI value of 0.1 nM; 12% of samples with DA above the RI had 3MT above 0.1 nM. CONCLUSIONS: The developed method allowed accurate quantitation of 3MT in patient samples and would provide valuable information to clinicians diagnosing or monitoring patients with PPGL. High 3MT concentrations in patient samples with MN and NMN within the respective RIs may alert clinicians of the possibility of a DA-producing tumor. Elsevier 2021-08-05 /pmc/articles/PMC8601001/ /pubmed/34820673 http://dx.doi.org/10.1016/j.jmsacl.2021.08.001 Text en © 2021 THE AUTHORS https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Regular Article
Smy, Laura
Kushnir, Mark M.
Frank, Elizabeth L.
A high sensitivity LC-MS/MS method for measurement of 3-methoxytyramine in plasma and associations between 3-methoxytyramine, metanephrines, and dopamine
title A high sensitivity LC-MS/MS method for measurement of 3-methoxytyramine in plasma and associations between 3-methoxytyramine, metanephrines, and dopamine
title_full A high sensitivity LC-MS/MS method for measurement of 3-methoxytyramine in plasma and associations between 3-methoxytyramine, metanephrines, and dopamine
title_fullStr A high sensitivity LC-MS/MS method for measurement of 3-methoxytyramine in plasma and associations between 3-methoxytyramine, metanephrines, and dopamine
title_full_unstemmed A high sensitivity LC-MS/MS method for measurement of 3-methoxytyramine in plasma and associations between 3-methoxytyramine, metanephrines, and dopamine
title_short A high sensitivity LC-MS/MS method for measurement of 3-methoxytyramine in plasma and associations between 3-methoxytyramine, metanephrines, and dopamine
title_sort high sensitivity lc-ms/ms method for measurement of 3-methoxytyramine in plasma and associations between 3-methoxytyramine, metanephrines, and dopamine
topic Regular Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8601001/
https://www.ncbi.nlm.nih.gov/pubmed/34820673
http://dx.doi.org/10.1016/j.jmsacl.2021.08.001
work_keys_str_mv AT smylaura ahighsensitivitylcmsmsmethodformeasurementof3methoxytyramineinplasmaandassociationsbetween3methoxytyraminemetanephrinesanddopamine
AT kushnirmarkm ahighsensitivitylcmsmsmethodformeasurementof3methoxytyramineinplasmaandassociationsbetween3methoxytyraminemetanephrinesanddopamine
AT frankelizabethl ahighsensitivitylcmsmsmethodformeasurementof3methoxytyramineinplasmaandassociationsbetween3methoxytyraminemetanephrinesanddopamine
AT smylaura highsensitivitylcmsmsmethodformeasurementof3methoxytyramineinplasmaandassociationsbetween3methoxytyraminemetanephrinesanddopamine
AT kushnirmarkm highsensitivitylcmsmsmethodformeasurementof3methoxytyramineinplasmaandassociationsbetween3methoxytyraminemetanephrinesanddopamine
AT frankelizabethl highsensitivitylcmsmsmethodformeasurementof3methoxytyramineinplasmaandassociationsbetween3methoxytyraminemetanephrinesanddopamine