Cargando…

Ravulizumab: Characterization and quantitation of a new C5 inhibitor using isotype specific affinity purification and high-resolution mass spectrometry

INTRODUCTION: Ravulizumab (RAVUL) is a new complement inhibitor, with a difference of 4 amino acids in the heavy chain from a predecessor compound, eculizumab (ECUL). OBJECTIVES: First, to utilize mass spectrometry (MS) to characterize RAVUL and verify differences from its predecessor and, second, t...

Descripción completa

Detalles Bibliográficos
Autores principales: Ladwig, Paula M., Willrich, Maria A.V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8601004/
https://www.ncbi.nlm.nih.gov/pubmed/34820672
http://dx.doi.org/10.1016/j.jmsacl.2021.08.002
_version_ 1784601261036797952
author Ladwig, Paula M.
Willrich, Maria A.V.
author_facet Ladwig, Paula M.
Willrich, Maria A.V.
author_sort Ladwig, Paula M.
collection PubMed
description INTRODUCTION: Ravulizumab (RAVUL) is a new complement inhibitor, with a difference of 4 amino acids in the heavy chain from a predecessor compound, eculizumab (ECUL). OBJECTIVES: First, to utilize mass spectrometry (MS) to characterize RAVUL and verify differences from its predecessor and, second, to validate and implement a lab developed test (LDT) for RAVUL that will allow for quantitative therapeutic monitoring. METHODS: A time-of-flight mass spectrometer (TOF-MS) was used to characterize and differentiate the molecular weight differences between RAVUL and ECUL by both digest and reduction experiments. In parallel, an LDT for RAVUL was validated and implemented utilizing IgG4 enrichment with light chain detection and quantitation on a high throughput orbitrap MS platform. RESULTS: The TOF-MS platform allowed for the mass difference between RAVUL and ECUL to be verified along with providing a proof of concept for a new intact protein quantitation software. An LDT on an orbitrap MS was validated and implemented using intact light chain quantitation, with the limitation that it cannot differentiate between ECUL and RAVUL. The LDT has an analytical measuring range from 5 to 600 mcg/mL, inter-assay imprecision of ≤13% CV (n = 13) and accuracy with <4% error from expected values (n = 20). CONCLUSION: The TOF-MS is a versatile development platform that can be used to characterize and verify the molecular weight differences between the ECUL and RAVUL heavy chains. Routine laboratory testing for RAVUL was viable using an orbitrap-MS to quantitate using the mass of the intact light chain. These two platforms, combined, provide incomparable value in development of LDTs for the clinical laboratory.
format Online
Article
Text
id pubmed-8601004
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-86010042021-11-23 Ravulizumab: Characterization and quantitation of a new C5 inhibitor using isotype specific affinity purification and high-resolution mass spectrometry Ladwig, Paula M. Willrich, Maria A.V. J Mass Spectrom Adv Clin Lab Research Article INTRODUCTION: Ravulizumab (RAVUL) is a new complement inhibitor, with a difference of 4 amino acids in the heavy chain from a predecessor compound, eculizumab (ECUL). OBJECTIVES: First, to utilize mass spectrometry (MS) to characterize RAVUL and verify differences from its predecessor and, second, to validate and implement a lab developed test (LDT) for RAVUL that will allow for quantitative therapeutic monitoring. METHODS: A time-of-flight mass spectrometer (TOF-MS) was used to characterize and differentiate the molecular weight differences between RAVUL and ECUL by both digest and reduction experiments. In parallel, an LDT for RAVUL was validated and implemented utilizing IgG4 enrichment with light chain detection and quantitation on a high throughput orbitrap MS platform. RESULTS: The TOF-MS platform allowed for the mass difference between RAVUL and ECUL to be verified along with providing a proof of concept for a new intact protein quantitation software. An LDT on an orbitrap MS was validated and implemented using intact light chain quantitation, with the limitation that it cannot differentiate between ECUL and RAVUL. The LDT has an analytical measuring range from 5 to 600 mcg/mL, inter-assay imprecision of ≤13% CV (n = 13) and accuracy with <4% error from expected values (n = 20). CONCLUSION: The TOF-MS is a versatile development platform that can be used to characterize and verify the molecular weight differences between the ECUL and RAVUL heavy chains. Routine laboratory testing for RAVUL was viable using an orbitrap-MS to quantitate using the mass of the intact light chain. These two platforms, combined, provide incomparable value in development of LDTs for the clinical laboratory. Elsevier 2021-08-12 /pmc/articles/PMC8601004/ /pubmed/34820672 http://dx.doi.org/10.1016/j.jmsacl.2021.08.002 Text en © 2021 THE AUTHORS https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Ladwig, Paula M.
Willrich, Maria A.V.
Ravulizumab: Characterization and quantitation of a new C5 inhibitor using isotype specific affinity purification and high-resolution mass spectrometry
title Ravulizumab: Characterization and quantitation of a new C5 inhibitor using isotype specific affinity purification and high-resolution mass spectrometry
title_full Ravulizumab: Characterization and quantitation of a new C5 inhibitor using isotype specific affinity purification and high-resolution mass spectrometry
title_fullStr Ravulizumab: Characterization and quantitation of a new C5 inhibitor using isotype specific affinity purification and high-resolution mass spectrometry
title_full_unstemmed Ravulizumab: Characterization and quantitation of a new C5 inhibitor using isotype specific affinity purification and high-resolution mass spectrometry
title_short Ravulizumab: Characterization and quantitation of a new C5 inhibitor using isotype specific affinity purification and high-resolution mass spectrometry
title_sort ravulizumab: characterization and quantitation of a new c5 inhibitor using isotype specific affinity purification and high-resolution mass spectrometry
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8601004/
https://www.ncbi.nlm.nih.gov/pubmed/34820672
http://dx.doi.org/10.1016/j.jmsacl.2021.08.002
work_keys_str_mv AT ladwigpaulam ravulizumabcharacterizationandquantitationofanewc5inhibitorusingisotypespecificaffinitypurificationandhighresolutionmassspectrometry
AT willrichmariaav ravulizumabcharacterizationandquantitationofanewc5inhibitorusingisotypespecificaffinitypurificationandhighresolutionmassspectrometry