Periprocedural complications of cardiac implantable electronic device implantation in very elderly patients with cognitive impairment: A prospective study

Very elderly people (over 80 years) with cardiac implantable electronic devices (CIEDs) indications often have a higher prevalence of aging comorbidity, among which cognitive impairment is not uncommon. This study aimed to investigate periprocedural complications of CIED implantation among very elde...

Descripción completa

Detalles Bibliográficos
Autores principales: Guan, Fu, Peng, Jianjun, Hou, Shu, Ren, Lihui, Yue, Yunan, Li, Guangping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8601302/
https://www.ncbi.nlm.nih.gov/pubmed/34797314
http://dx.doi.org/10.1097/MD.0000000000027837
_version_ 1784601315055239168
author Guan, Fu
Peng, Jianjun
Hou, Shu
Ren, Lihui
Yue, Yunan
Li, Guangping
author_facet Guan, Fu
Peng, Jianjun
Hou, Shu
Ren, Lihui
Yue, Yunan
Li, Guangping
author_sort Guan, Fu
collection PubMed
description Very elderly people (over 80 years) with cardiac implantable electronic devices (CIEDs) indications often have a higher prevalence of aging comorbidity, among which cognitive impairment is not uncommon. This study aimed to investigate periprocedural complications of CIED implantation among very elderly patients with and without cognitive impairment. One hundred eighty patients ≥80 years of age indicated for CIED implantation were included in our study. During hospitalization, the cognitive evaluation was performed according to the Diagnostic and Statistical Manual of Mental Disorders (fifth edition). According to the cognitive test results, patients were divided into 2 groups (90 patients with normal cognitive function and 90 patients with cognitive impairment). Meanwhile, their physical parameters and laboratory measurements were completed. The procedural data and periprocedural complications were collected from both groups. The association between cognitive impairment and periprocedural complications was analyzed using univariate and multiple logistic regression analyses. During a one-month follow-up, the most frequent periprocedural complications in very elderly patients were pocket hematoma and thrombosis events. Cognitively impaired patients had a higher incidence of complications than normal cognitive patients. Multivariate regression analysis showed that cognitive impairment was positively correlated with periprocedural complications in very elderly patients. Cognitive impairment is associated with increased periprocedural complications of CIED implantation in very elderly patients.
format Online
Article
Text
id pubmed-8601302
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-86013022021-11-20 Periprocedural complications of cardiac implantable electronic device implantation in very elderly patients with cognitive impairment: A prospective study Guan, Fu Peng, Jianjun Hou, Shu Ren, Lihui Yue, Yunan Li, Guangping Medicine (Baltimore) 4600 Very elderly people (over 80 years) with cardiac implantable electronic devices (CIEDs) indications often have a higher prevalence of aging comorbidity, among which cognitive impairment is not uncommon. This study aimed to investigate periprocedural complications of CIED implantation among very elderly patients with and without cognitive impairment. One hundred eighty patients ≥80 years of age indicated for CIED implantation were included in our study. During hospitalization, the cognitive evaluation was performed according to the Diagnostic and Statistical Manual of Mental Disorders (fifth edition). According to the cognitive test results, patients were divided into 2 groups (90 patients with normal cognitive function and 90 patients with cognitive impairment). Meanwhile, their physical parameters and laboratory measurements were completed. The procedural data and periprocedural complications were collected from both groups. The association between cognitive impairment and periprocedural complications was analyzed using univariate and multiple logistic regression analyses. During a one-month follow-up, the most frequent periprocedural complications in very elderly patients were pocket hematoma and thrombosis events. Cognitively impaired patients had a higher incidence of complications than normal cognitive patients. Multivariate regression analysis showed that cognitive impairment was positively correlated with periprocedural complications in very elderly patients. Cognitive impairment is associated with increased periprocedural complications of CIED implantation in very elderly patients. Lippincott Williams & Wilkins 2021-11-19 /pmc/articles/PMC8601302/ /pubmed/34797314 http://dx.doi.org/10.1097/MD.0000000000027837 Text en Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 (https://creativecommons.org/licenses/by/4.0/)
spellingShingle 4600
Guan, Fu
Peng, Jianjun
Hou, Shu
Ren, Lihui
Yue, Yunan
Li, Guangping
Periprocedural complications of cardiac implantable electronic device implantation in very elderly patients with cognitive impairment: A prospective study
title Periprocedural complications of cardiac implantable electronic device implantation in very elderly patients with cognitive impairment: A prospective study
title_full Periprocedural complications of cardiac implantable electronic device implantation in very elderly patients with cognitive impairment: A prospective study
title_fullStr Periprocedural complications of cardiac implantable electronic device implantation in very elderly patients with cognitive impairment: A prospective study
title_full_unstemmed Periprocedural complications of cardiac implantable electronic device implantation in very elderly patients with cognitive impairment: A prospective study
title_short Periprocedural complications of cardiac implantable electronic device implantation in very elderly patients with cognitive impairment: A prospective study
title_sort periprocedural complications of cardiac implantable electronic device implantation in very elderly patients with cognitive impairment: a prospective study
topic 4600
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8601302/
https://www.ncbi.nlm.nih.gov/pubmed/34797314
http://dx.doi.org/10.1097/MD.0000000000027837
work_keys_str_mv AT guanfu periproceduralcomplicationsofcardiacimplantableelectronicdeviceimplantationinveryelderlypatientswithcognitiveimpairmentaprospectivestudy
AT pengjianjun periproceduralcomplicationsofcardiacimplantableelectronicdeviceimplantationinveryelderlypatientswithcognitiveimpairmentaprospectivestudy
AT houshu periproceduralcomplicationsofcardiacimplantableelectronicdeviceimplantationinveryelderlypatientswithcognitiveimpairmentaprospectivestudy
AT renlihui periproceduralcomplicationsofcardiacimplantableelectronicdeviceimplantationinveryelderlypatientswithcognitiveimpairmentaprospectivestudy
AT yueyunan periproceduralcomplicationsofcardiacimplantableelectronicdeviceimplantationinveryelderlypatientswithcognitiveimpairmentaprospectivestudy
AT liguangping periproceduralcomplicationsofcardiacimplantableelectronicdeviceimplantationinveryelderlypatientswithcognitiveimpairmentaprospectivestudy