Cargando…
Evaluation of bone formation on orthopedic implant surfaces using an ex-vivo bone bioreactor system
Recent advances in materials and manufacturing processes have allowed the fabrication of intricate implant surfaces to facilitate bony attachment. However, refinement and evaluation of these new design strategies are hindered by the cost and complications of animal studies, particularly during early...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8602619/ https://www.ncbi.nlm.nih.gov/pubmed/34795368 http://dx.doi.org/10.1038/s41598-021-02070-z |
_version_ | 1784601609497477120 |
---|---|
author | Dua, Rupak Jones, Hugh Noble, Philip C. |
author_facet | Dua, Rupak Jones, Hugh Noble, Philip C. |
author_sort | Dua, Rupak |
collection | PubMed |
description | Recent advances in materials and manufacturing processes have allowed the fabrication of intricate implant surfaces to facilitate bony attachment. However, refinement and evaluation of these new design strategies are hindered by the cost and complications of animal studies, particularly during early iterations in the development process. To address this problem, we have previously constructed and validated an ex-vivo bone bioreactor culture system that can maintain the viability of bone samples for an extended period ex-vivo. In this study, we investigated the mineralization of a titanium wire mesh scaffold under both static and dynamic culturing using our ex vivo bioreactor system. Thirty-six cancellous bone cores were harvested from bovine metatarsals at the time of slaughter and divided into five groups under the following conditions: Group 1) Isolated bone cores placed in static culture, Group 2) Unloaded bone cores placed in static culture in contact with a fiber-mesh metallic scaffold, Group 3) Bone cores placed in contact with a fiber-mesh metallic scaffold under the constant pressure of 150 kPa, Group 4) Bone core placed in contact with a fiber-mesh metallic scaffold and exposed to cyclic loading with continuous perfusion flow of media within the ex-vivo culture system and Group 5) Bone core evaluated on Day 0 to serve as a positive control for comparison with all other groups at weeks 4 and 7. Bone samples within Groups 1–4 were incubated for 4 and 7 weeks and then evaluated using histological examination (H&E) and the Live-Dead assay (Life Technologies). Matrix deposits on the metallic scaffolds were examined with scanning electron microscopy (SEM), while the chemical composition of the matrix was measured using energy-dispersive x-ray spectroscopy (EDX). We found that the viability of bone cores was maintained after seven weeks of loading in our ex vivo system. In addition, SEM images revealed crystallite-like structures on the dynamically loaded metal coupons (Group 4), corresponding to the initial stages of mineralization. EDX results further confirmed the presence of carbon at the interface and calcium phosphates in the matrix. We conclude that a bone bioreactor can be used as an alternate tool for in-vivo bone ingrowth studies of new implant surfaces or coatings. |
format | Online Article Text |
id | pubmed-8602619 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-86026192021-11-22 Evaluation of bone formation on orthopedic implant surfaces using an ex-vivo bone bioreactor system Dua, Rupak Jones, Hugh Noble, Philip C. Sci Rep Article Recent advances in materials and manufacturing processes have allowed the fabrication of intricate implant surfaces to facilitate bony attachment. However, refinement and evaluation of these new design strategies are hindered by the cost and complications of animal studies, particularly during early iterations in the development process. To address this problem, we have previously constructed and validated an ex-vivo bone bioreactor culture system that can maintain the viability of bone samples for an extended period ex-vivo. In this study, we investigated the mineralization of a titanium wire mesh scaffold under both static and dynamic culturing using our ex vivo bioreactor system. Thirty-six cancellous bone cores were harvested from bovine metatarsals at the time of slaughter and divided into five groups under the following conditions: Group 1) Isolated bone cores placed in static culture, Group 2) Unloaded bone cores placed in static culture in contact with a fiber-mesh metallic scaffold, Group 3) Bone cores placed in contact with a fiber-mesh metallic scaffold under the constant pressure of 150 kPa, Group 4) Bone core placed in contact with a fiber-mesh metallic scaffold and exposed to cyclic loading with continuous perfusion flow of media within the ex-vivo culture system and Group 5) Bone core evaluated on Day 0 to serve as a positive control for comparison with all other groups at weeks 4 and 7. Bone samples within Groups 1–4 were incubated for 4 and 7 weeks and then evaluated using histological examination (H&E) and the Live-Dead assay (Life Technologies). Matrix deposits on the metallic scaffolds were examined with scanning electron microscopy (SEM), while the chemical composition of the matrix was measured using energy-dispersive x-ray spectroscopy (EDX). We found that the viability of bone cores was maintained after seven weeks of loading in our ex vivo system. In addition, SEM images revealed crystallite-like structures on the dynamically loaded metal coupons (Group 4), corresponding to the initial stages of mineralization. EDX results further confirmed the presence of carbon at the interface and calcium phosphates in the matrix. We conclude that a bone bioreactor can be used as an alternate tool for in-vivo bone ingrowth studies of new implant surfaces or coatings. Nature Publishing Group UK 2021-11-18 /pmc/articles/PMC8602619/ /pubmed/34795368 http://dx.doi.org/10.1038/s41598-021-02070-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Dua, Rupak Jones, Hugh Noble, Philip C. Evaluation of bone formation on orthopedic implant surfaces using an ex-vivo bone bioreactor system |
title | Evaluation of bone formation on orthopedic implant surfaces using an ex-vivo bone bioreactor system |
title_full | Evaluation of bone formation on orthopedic implant surfaces using an ex-vivo bone bioreactor system |
title_fullStr | Evaluation of bone formation on orthopedic implant surfaces using an ex-vivo bone bioreactor system |
title_full_unstemmed | Evaluation of bone formation on orthopedic implant surfaces using an ex-vivo bone bioreactor system |
title_short | Evaluation of bone formation on orthopedic implant surfaces using an ex-vivo bone bioreactor system |
title_sort | evaluation of bone formation on orthopedic implant surfaces using an ex-vivo bone bioreactor system |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8602619/ https://www.ncbi.nlm.nih.gov/pubmed/34795368 http://dx.doi.org/10.1038/s41598-021-02070-z |
work_keys_str_mv | AT duarupak evaluationofboneformationonorthopedicimplantsurfacesusinganexvivobonebioreactorsystem AT joneshugh evaluationofboneformationonorthopedicimplantsurfacesusinganexvivobonebioreactorsystem AT noblephilipc evaluationofboneformationonorthopedicimplantsurfacesusinganexvivobonebioreactorsystem |