Cargando…

Improving Deep Brain Stimulation Electrode Performance in vivo Through Use of Conductive Hydrogel Coatings

Active implantable neurological devices like deep brain stimulators have been used over the past few decades to treat movement disorders such as those in people with Parkinson’s disease and more recently, in psychiatric conditions like obsessive compulsive disorder. Electrode-tissue interfaces that...

Descripción completa

Detalles Bibliográficos
Autores principales: Hyakumura, Tomoko, Aregueta-Robles, Ulises, Duan, Wenlu, Villalobos, Joel, Adams, Wendy K., Poole-Warren, Laura, Fallon, James B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8602793/
https://www.ncbi.nlm.nih.gov/pubmed/34803592
http://dx.doi.org/10.3389/fnins.2021.761525
_version_ 1784601634100215808
author Hyakumura, Tomoko
Aregueta-Robles, Ulises
Duan, Wenlu
Villalobos, Joel
Adams, Wendy K.
Poole-Warren, Laura
Fallon, James B.
author_facet Hyakumura, Tomoko
Aregueta-Robles, Ulises
Duan, Wenlu
Villalobos, Joel
Adams, Wendy K.
Poole-Warren, Laura
Fallon, James B.
author_sort Hyakumura, Tomoko
collection PubMed
description Active implantable neurological devices like deep brain stimulators have been used over the past few decades to treat movement disorders such as those in people with Parkinson’s disease and more recently, in psychiatric conditions like obsessive compulsive disorder. Electrode-tissue interfaces that support safe and effective targeting of specific brain regions are critical to success of these devices. Development of directional electrodes that activate smaller volumes of brain tissue requires electrodes to operate safely with higher charge densities. Coatings such as conductive hydrogels (CHs) provide lower impedances and higher charge injection limits (CILs) than standard platinum electrodes and support safer application of smaller electrode sizes. The aim of this study was to examine the chronic in vivo performance of a new low swelling CH coating that supports higher safe charge densities than traditional platinum electrodes. A range of hydrogel blends were engineered and their swelling and electrical performance compared. Electrochemical performance and stability of high and low swelling formulations were compared during insertion into a model brain in vitro and the formulation with lower swelling characteristics was chosen for the in vivo study. CH-coated or uncoated Pt electrode arrays were implanted into the brains of 14 rats, and their electrochemical performance was tested weekly for 8 weeks. Tissue response and neural survival was assessed histologically following electrode array removal. CH coating resulted in significantly lower voltage transient impedance, higher CIL, lower electrochemical impedance spectroscopy, and higher charge storage capacity compared to uncoated Pt electrodes in vivo, and this advantage was maintained over the 8-week implantation. There was no significant difference in evoked potential thresholds, signal-to-noise ratio, tissue response or neural survival between CH-coated and uncoated Pt groups. The significant electrochemical advantage and stability of CH coating in the brain supports the suitability of this coating technology for future development of smaller, higher fidelity electrode arrays with higher charge density requirement.
format Online
Article
Text
id pubmed-8602793
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-86027932021-11-20 Improving Deep Brain Stimulation Electrode Performance in vivo Through Use of Conductive Hydrogel Coatings Hyakumura, Tomoko Aregueta-Robles, Ulises Duan, Wenlu Villalobos, Joel Adams, Wendy K. Poole-Warren, Laura Fallon, James B. Front Neurosci Neuroscience Active implantable neurological devices like deep brain stimulators have been used over the past few decades to treat movement disorders such as those in people with Parkinson’s disease and more recently, in psychiatric conditions like obsessive compulsive disorder. Electrode-tissue interfaces that support safe and effective targeting of specific brain regions are critical to success of these devices. Development of directional electrodes that activate smaller volumes of brain tissue requires electrodes to operate safely with higher charge densities. Coatings such as conductive hydrogels (CHs) provide lower impedances and higher charge injection limits (CILs) than standard platinum electrodes and support safer application of smaller electrode sizes. The aim of this study was to examine the chronic in vivo performance of a new low swelling CH coating that supports higher safe charge densities than traditional platinum electrodes. A range of hydrogel blends were engineered and their swelling and electrical performance compared. Electrochemical performance and stability of high and low swelling formulations were compared during insertion into a model brain in vitro and the formulation with lower swelling characteristics was chosen for the in vivo study. CH-coated or uncoated Pt electrode arrays were implanted into the brains of 14 rats, and their electrochemical performance was tested weekly for 8 weeks. Tissue response and neural survival was assessed histologically following electrode array removal. CH coating resulted in significantly lower voltage transient impedance, higher CIL, lower electrochemical impedance spectroscopy, and higher charge storage capacity compared to uncoated Pt electrodes in vivo, and this advantage was maintained over the 8-week implantation. There was no significant difference in evoked potential thresholds, signal-to-noise ratio, tissue response or neural survival between CH-coated and uncoated Pt groups. The significant electrochemical advantage and stability of CH coating in the brain supports the suitability of this coating technology for future development of smaller, higher fidelity electrode arrays with higher charge density requirement. Frontiers Media S.A. 2021-11-05 /pmc/articles/PMC8602793/ /pubmed/34803592 http://dx.doi.org/10.3389/fnins.2021.761525 Text en Copyright © 2021 Hyakumura, Aregueta-Robles, Duan, Villalobos, Adams, Poole-Warren and Fallon. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Hyakumura, Tomoko
Aregueta-Robles, Ulises
Duan, Wenlu
Villalobos, Joel
Adams, Wendy K.
Poole-Warren, Laura
Fallon, James B.
Improving Deep Brain Stimulation Electrode Performance in vivo Through Use of Conductive Hydrogel Coatings
title Improving Deep Brain Stimulation Electrode Performance in vivo Through Use of Conductive Hydrogel Coatings
title_full Improving Deep Brain Stimulation Electrode Performance in vivo Through Use of Conductive Hydrogel Coatings
title_fullStr Improving Deep Brain Stimulation Electrode Performance in vivo Through Use of Conductive Hydrogel Coatings
title_full_unstemmed Improving Deep Brain Stimulation Electrode Performance in vivo Through Use of Conductive Hydrogel Coatings
title_short Improving Deep Brain Stimulation Electrode Performance in vivo Through Use of Conductive Hydrogel Coatings
title_sort improving deep brain stimulation electrode performance in vivo through use of conductive hydrogel coatings
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8602793/
https://www.ncbi.nlm.nih.gov/pubmed/34803592
http://dx.doi.org/10.3389/fnins.2021.761525
work_keys_str_mv AT hyakumuratomoko improvingdeepbrainstimulationelectrodeperformanceinvivothroughuseofconductivehydrogelcoatings
AT areguetaroblesulises improvingdeepbrainstimulationelectrodeperformanceinvivothroughuseofconductivehydrogelcoatings
AT duanwenlu improvingdeepbrainstimulationelectrodeperformanceinvivothroughuseofconductivehydrogelcoatings
AT villalobosjoel improvingdeepbrainstimulationelectrodeperformanceinvivothroughuseofconductivehydrogelcoatings
AT adamswendyk improvingdeepbrainstimulationelectrodeperformanceinvivothroughuseofconductivehydrogelcoatings
AT poolewarrenlaura improvingdeepbrainstimulationelectrodeperformanceinvivothroughuseofconductivehydrogelcoatings
AT fallonjamesb improvingdeepbrainstimulationelectrodeperformanceinvivothroughuseofconductivehydrogelcoatings