Cargando…

Continuous Renal Replacement Therapy for Two Neonates With Hyperammonemia

Objectives: This study aims to assess the feasibility of using hemofiltration for ammonia clearance in low body weight infants with an inborn error of metabolism. Design: A study of two cases. Setting: Quaternary pediatric hospital (Saint Louis Children's Hospital) NICU and PICU. Patients: Infa...

Descripción completa

Detalles Bibliográficos
Autores principales: Markham, Christopher, Williams, Caroline, Miller, Cory, Grange, Dorothy K., Davis, T. Keefe, Remy, Kenneth E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8602909/
https://www.ncbi.nlm.nih.gov/pubmed/34805036
http://dx.doi.org/10.3389/fped.2021.732354
Descripción
Sumario:Objectives: This study aims to assess the feasibility of using hemofiltration for ammonia clearance in low body weight infants with an inborn error of metabolism. Design: A study of two cases. Setting: Quaternary pediatric hospital (Saint Louis Children's Hospital) NICU and PICU. Patients: Infants <6 months of age with an ICD-9 diagnosis of 270.6 (hyperammonemia). Interventions: Continuous renal replacement therapy (CRRT). Measurements and Main Results: We measure serum ammonia levels over time and the rate of ammonia clearance over time. Continuous renal replacement therapy was more effective than scavenger therapy alone (Ammonul™) for rapid removal of ammonia in low weight infants (as low as 2.5 kg). Conclusions: Continuous renal replacement therapy is technically feasible in low weight infants with severe hyperammonemia secondary to an inborn error of metabolism.