Cargando…
Permanent pacemaker implantation after On-X surgical aortic valve replacement: SWEDEHEART observational study
OBJECTIVE: Bioprosthetic aortic valves with an extended subannular component, such as transcatheter valves, exert increased compression on the cardiac conduction system and increase the risk for permanent pacemaker implantation. It is unknown if the On-X mechanical prosthetic valve, which has an elo...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8603281/ https://www.ncbi.nlm.nih.gov/pubmed/34794986 http://dx.doi.org/10.1136/bmjopen-2020-047962 |
_version_ | 1784601738753343488 |
---|---|
author | Dalén, Magnus Persson, Michael Glaser, Natalie Sartipy, Ulrik |
author_facet | Dalén, Magnus Persson, Michael Glaser, Natalie Sartipy, Ulrik |
author_sort | Dalén, Magnus |
collection | PubMed |
description | OBJECTIVE: Bioprosthetic aortic valves with an extended subannular component, such as transcatheter valves, exert increased compression on the cardiac conduction system and increase the risk for permanent pacemaker implantation. It is unknown if the On-X mechanical prosthetic valve, which has an elongated subannular valve housing, increases the risk of permanent pacemaker implantation following aortic valve replacement. DESIGN: Observational nationwide cohort study. SETTING: Swedish population-based study. PARTICIPANTS: All patients aged 18–65 years who underwent primary mechanical aortic valve replacement in Sweden between 2005 and 2018. We used the Swedish Web system for Enhancement and Development of Evidence-based care in Heart disease Evaluated According to Recommended Therapies register and other Swedish national health-data registers. EXPOSURE: Patients implanted with an On-X valve versus patients implanted with other bileaflet mechanical valves. PRIMARY AND SECONDARY OUTCOME MEASURES: Primary outcome measure was permanent pacemaker implantation within 30 days of surgery. RESULTS: A total of 2602 patients were included, and 581 patients received an On-X valve and 2021 patients received a St Jude Masters/Regent (n=945) or Carbomedics Reduced valve (n=1076). In the total study population, 115 (4.4%) permanent pacemaker implantations were performed within 30 days after aortic valve replacement. In the propensity score matched population, there was no significant difference in the rate of permanent pacemaker implantation in the On-X group compared with the control group: 3.6% (95% CI: 2.4% to 5.5%) vs 4.0% (95% CI: 2.7% to 5.9%), p=0.877. CONCLUSIONS: The On-X prosthetic heart valve was associated with a similarly low risk for permanent pacemaker implantation after aortic valve replacement compared with other conventional bileaflet mechanical valves. The On-X elongated subannular valve housing does not interfere with the cardiac conduction system. |
format | Online Article Text |
id | pubmed-8603281 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-86032812021-12-03 Permanent pacemaker implantation after On-X surgical aortic valve replacement: SWEDEHEART observational study Dalén, Magnus Persson, Michael Glaser, Natalie Sartipy, Ulrik BMJ Open Surgery OBJECTIVE: Bioprosthetic aortic valves with an extended subannular component, such as transcatheter valves, exert increased compression on the cardiac conduction system and increase the risk for permanent pacemaker implantation. It is unknown if the On-X mechanical prosthetic valve, which has an elongated subannular valve housing, increases the risk of permanent pacemaker implantation following aortic valve replacement. DESIGN: Observational nationwide cohort study. SETTING: Swedish population-based study. PARTICIPANTS: All patients aged 18–65 years who underwent primary mechanical aortic valve replacement in Sweden between 2005 and 2018. We used the Swedish Web system for Enhancement and Development of Evidence-based care in Heart disease Evaluated According to Recommended Therapies register and other Swedish national health-data registers. EXPOSURE: Patients implanted with an On-X valve versus patients implanted with other bileaflet mechanical valves. PRIMARY AND SECONDARY OUTCOME MEASURES: Primary outcome measure was permanent pacemaker implantation within 30 days of surgery. RESULTS: A total of 2602 patients were included, and 581 patients received an On-X valve and 2021 patients received a St Jude Masters/Regent (n=945) or Carbomedics Reduced valve (n=1076). In the total study population, 115 (4.4%) permanent pacemaker implantations were performed within 30 days after aortic valve replacement. In the propensity score matched population, there was no significant difference in the rate of permanent pacemaker implantation in the On-X group compared with the control group: 3.6% (95% CI: 2.4% to 5.5%) vs 4.0% (95% CI: 2.7% to 5.9%), p=0.877. CONCLUSIONS: The On-X prosthetic heart valve was associated with a similarly low risk for permanent pacemaker implantation after aortic valve replacement compared with other conventional bileaflet mechanical valves. The On-X elongated subannular valve housing does not interfere with the cardiac conduction system. BMJ Publishing Group 2021-11-17 /pmc/articles/PMC8603281/ /pubmed/34794986 http://dx.doi.org/10.1136/bmjopen-2020-047962 Text en © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY. Published by BMJ. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution 4.0 Unported (CC BY 4.0) license, which permits others to copy, redistribute, remix, transform and build upon this work for any purpose, provided the original work is properly cited, a link to the licence is given, and indication of whether changes were made. See: https://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Surgery Dalén, Magnus Persson, Michael Glaser, Natalie Sartipy, Ulrik Permanent pacemaker implantation after On-X surgical aortic valve replacement: SWEDEHEART observational study |
title | Permanent pacemaker implantation after On-X surgical aortic valve replacement: SWEDEHEART observational study |
title_full | Permanent pacemaker implantation after On-X surgical aortic valve replacement: SWEDEHEART observational study |
title_fullStr | Permanent pacemaker implantation after On-X surgical aortic valve replacement: SWEDEHEART observational study |
title_full_unstemmed | Permanent pacemaker implantation after On-X surgical aortic valve replacement: SWEDEHEART observational study |
title_short | Permanent pacemaker implantation after On-X surgical aortic valve replacement: SWEDEHEART observational study |
title_sort | permanent pacemaker implantation after on-x surgical aortic valve replacement: swedeheart observational study |
topic | Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8603281/ https://www.ncbi.nlm.nih.gov/pubmed/34794986 http://dx.doi.org/10.1136/bmjopen-2020-047962 |
work_keys_str_mv | AT dalenmagnus permanentpacemakerimplantationafteronxsurgicalaorticvalvereplacementswedeheartobservationalstudy AT perssonmichael permanentpacemakerimplantationafteronxsurgicalaorticvalvereplacementswedeheartobservationalstudy AT glasernatalie permanentpacemakerimplantationafteronxsurgicalaorticvalvereplacementswedeheartobservationalstudy AT sartipyulrik permanentpacemakerimplantationafteronxsurgicalaorticvalvereplacementswedeheartobservationalstudy |