Cargando…

Helicopter emergency medical services use of thoracic point of care ultrasound for pneumothorax: a systematic review and meta-analysis

BACKGROUND: Auscultating for breath sounds to assess for pneumothorax in the helicopter emergency medical services (HEMS) settings can be extremely challenging. Thoracic point of care ultrasound (POCUS) offers a seemingly more useful visual (rather than audible) alternative. This review critically a...

Descripción completa

Detalles Bibliográficos
Autor principal: Griffiths, Edward
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606084/
https://www.ncbi.nlm.nih.gov/pubmed/34801070
http://dx.doi.org/10.1186/s13049-021-00977-0
_version_ 1784602278886375424
author Griffiths, Edward
author_facet Griffiths, Edward
author_sort Griffiths, Edward
collection PubMed
description BACKGROUND: Auscultating for breath sounds to assess for pneumothorax in the helicopter emergency medical services (HEMS) settings can be extremely challenging. Thoracic point of care ultrasound (POCUS) offers a seemingly more useful visual (rather than audible) alternative. This review critically and quantitatively evaluates the use of thoracic POCUS for pneumothorax in the HEMS setting. METHODS: A systematic literature review with meta-analysis was conducted. Only papers reporting on patients undergoing POCUS for pneumothorax in the helicopter or pre-hospital setting were included. Primary outcome was accuracy, focusing on sensitivity and specificity. Secondary outcome was practicality. PubMed, Embase and the Cochrane Library were searched. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) was used to assess validity of studies. RESULTS: Twelve studies reporting on n = 1,936 images from medical and trauma patients were included in qualitative synthesis. Studies were nearly all observational designs. Most images were acquired by nurses or paramedics who were previously novices to ultrasound. The reference standard was predominantly CT. Specificity results were unanimously precise and very high, whereas sensitivity results were imprecise and extremely variable. Meta-analysis of eight studies involving n = 1,713 images yielded pooled sensitivity 61% (95% CI: 27–87%; I(2) = 94%) and pooled specificity 99% (95% CI: 98–100%; I(2) = 89%). Six studies involving n = 315 images reported practicality. The highest or second highest categorisation of image quality was reported in around half of those images. CONCLUSION: Thoracic POCUS is highly specific but has extremely variable sensitivity for pneumothorax when performed in the HEMS setting. This is from purely a diagnostic (not clinical) perspective. Sensitivity increases when only clinically significant pneumothoraces are considered. Case reports reveal thoracic POCUS can appropriately alter treatment and triage decisions, but only for a small number of patients. It appears predominantly useful in mitigating against unnecessary interventions. More research reporting patient focused outcomes is required. In the meantime, thoracic POCUS appears to offer a more appropriate visual alternative to auscultation for breath sounds when assessing for pneumothorax in the HEMS setting.
format Online
Article
Text
id pubmed-8606084
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-86060842021-11-22 Helicopter emergency medical services use of thoracic point of care ultrasound for pneumothorax: a systematic review and meta-analysis Griffiths, Edward Scand J Trauma Resusc Emerg Med Review BACKGROUND: Auscultating for breath sounds to assess for pneumothorax in the helicopter emergency medical services (HEMS) settings can be extremely challenging. Thoracic point of care ultrasound (POCUS) offers a seemingly more useful visual (rather than audible) alternative. This review critically and quantitatively evaluates the use of thoracic POCUS for pneumothorax in the HEMS setting. METHODS: A systematic literature review with meta-analysis was conducted. Only papers reporting on patients undergoing POCUS for pneumothorax in the helicopter or pre-hospital setting were included. Primary outcome was accuracy, focusing on sensitivity and specificity. Secondary outcome was practicality. PubMed, Embase and the Cochrane Library were searched. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) was used to assess validity of studies. RESULTS: Twelve studies reporting on n = 1,936 images from medical and trauma patients were included in qualitative synthesis. Studies were nearly all observational designs. Most images were acquired by nurses or paramedics who were previously novices to ultrasound. The reference standard was predominantly CT. Specificity results were unanimously precise and very high, whereas sensitivity results were imprecise and extremely variable. Meta-analysis of eight studies involving n = 1,713 images yielded pooled sensitivity 61% (95% CI: 27–87%; I(2) = 94%) and pooled specificity 99% (95% CI: 98–100%; I(2) = 89%). Six studies involving n = 315 images reported practicality. The highest or second highest categorisation of image quality was reported in around half of those images. CONCLUSION: Thoracic POCUS is highly specific but has extremely variable sensitivity for pneumothorax when performed in the HEMS setting. This is from purely a diagnostic (not clinical) perspective. Sensitivity increases when only clinically significant pneumothoraces are considered. Case reports reveal thoracic POCUS can appropriately alter treatment and triage decisions, but only for a small number of patients. It appears predominantly useful in mitigating against unnecessary interventions. More research reporting patient focused outcomes is required. In the meantime, thoracic POCUS appears to offer a more appropriate visual alternative to auscultation for breath sounds when assessing for pneumothorax in the HEMS setting. BioMed Central 2021-11-20 /pmc/articles/PMC8606084/ /pubmed/34801070 http://dx.doi.org/10.1186/s13049-021-00977-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Review
Griffiths, Edward
Helicopter emergency medical services use of thoracic point of care ultrasound for pneumothorax: a systematic review and meta-analysis
title Helicopter emergency medical services use of thoracic point of care ultrasound for pneumothorax: a systematic review and meta-analysis
title_full Helicopter emergency medical services use of thoracic point of care ultrasound for pneumothorax: a systematic review and meta-analysis
title_fullStr Helicopter emergency medical services use of thoracic point of care ultrasound for pneumothorax: a systematic review and meta-analysis
title_full_unstemmed Helicopter emergency medical services use of thoracic point of care ultrasound for pneumothorax: a systematic review and meta-analysis
title_short Helicopter emergency medical services use of thoracic point of care ultrasound for pneumothorax: a systematic review and meta-analysis
title_sort helicopter emergency medical services use of thoracic point of care ultrasound for pneumothorax: a systematic review and meta-analysis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606084/
https://www.ncbi.nlm.nih.gov/pubmed/34801070
http://dx.doi.org/10.1186/s13049-021-00977-0
work_keys_str_mv AT griffithsedward helicopteremergencymedicalservicesuseofthoracicpointofcareultrasoundforpneumothoraxasystematicreviewandmetaanalysis