Cargando…

Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography?

BACKGROUND: The effect of right ventricular (RV) leads on tricuspid valve has been already raised concerns, especially in terms of prognostic implication. For such assessment, three-dimensional transthoracic echocardiography (3D-TTE) has been used previously but there was no data on the use of post-...

Descripción completa

Detalles Bibliográficos
Autores principales: Poorzand, Hoorak, Tayyebi, Mohammad, Hosseini, Sara, Bakavoli, Alireza Heidari, Keihanian, Faeze, Jarahi, Lida, Hamadanchi, Ali
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606093/
https://www.ncbi.nlm.nih.gov/pubmed/34802441
http://dx.doi.org/10.1186/s12947-021-00267-w
_version_ 1784602281062170624
author Poorzand, Hoorak
Tayyebi, Mohammad
Hosseini, Sara
Bakavoli, Alireza Heidari
Keihanian, Faeze
Jarahi, Lida
Hamadanchi, Ali
author_facet Poorzand, Hoorak
Tayyebi, Mohammad
Hosseini, Sara
Bakavoli, Alireza Heidari
Keihanian, Faeze
Jarahi, Lida
Hamadanchi, Ali
author_sort Poorzand, Hoorak
collection PubMed
description BACKGROUND: The effect of right ventricular (RV) leads on tricuspid valve has been already raised concerns, especially in terms of prognostic implication. For such assessment, three-dimensional transthoracic echocardiography (3D-TTE) has been used previously but there was no data on the use of post-procedural fluoroscopy in the literature. METHODS: We prospectively enrolled 59 patients who underwent clinically indicated placement of pacemaker or implantable cardioverter defibrillator (ICD). Vena contracta (VC) and tricuspid regurgitation (TR) severity were measured using two-dimensional transthoracic echocardiography (2D-TTE) at baseline. Follow up 3D-TTE was performed 6 months after device implantation to assess TR severity and RV lead location. RESULTS: Lead placement position in TV was defined in 51 cases.TR VC was increased after the lead placement, compared to the baseline study (VC: 3.86 ± 2.32 vs 3.18 ± 2.39; p = 0.005), with one grade worsening in TR in 25.4% of cases. The mean changes in VC levels were 1.14 ± 0.67 mm. Among all investigated parameters, VC changes were predicted based on lead placement position only in 3D-TTE (p < 0.001) while the other variables including fluoroscopy parameters were not informative. CONCLUSION: The RV Lead location examined by 3D-TTE seems to be a valuable parameter to predict the changes in the severity of the tricuspid regurgitation. Fluoroscopy findings did not improve the predictive performance, at least in short term follow up.
format Online
Article
Text
id pubmed-8606093
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-86060932021-11-22 Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography? Poorzand, Hoorak Tayyebi, Mohammad Hosseini, Sara Bakavoli, Alireza Heidari Keihanian, Faeze Jarahi, Lida Hamadanchi, Ali Cardiovasc Ultrasound Research BACKGROUND: The effect of right ventricular (RV) leads on tricuspid valve has been already raised concerns, especially in terms of prognostic implication. For such assessment, three-dimensional transthoracic echocardiography (3D-TTE) has been used previously but there was no data on the use of post-procedural fluoroscopy in the literature. METHODS: We prospectively enrolled 59 patients who underwent clinically indicated placement of pacemaker or implantable cardioverter defibrillator (ICD). Vena contracta (VC) and tricuspid regurgitation (TR) severity were measured using two-dimensional transthoracic echocardiography (2D-TTE) at baseline. Follow up 3D-TTE was performed 6 months after device implantation to assess TR severity and RV lead location. RESULTS: Lead placement position in TV was defined in 51 cases.TR VC was increased after the lead placement, compared to the baseline study (VC: 3.86 ± 2.32 vs 3.18 ± 2.39; p = 0.005), with one grade worsening in TR in 25.4% of cases. The mean changes in VC levels were 1.14 ± 0.67 mm. Among all investigated parameters, VC changes were predicted based on lead placement position only in 3D-TTE (p < 0.001) while the other variables including fluoroscopy parameters were not informative. CONCLUSION: The RV Lead location examined by 3D-TTE seems to be a valuable parameter to predict the changes in the severity of the tricuspid regurgitation. Fluoroscopy findings did not improve the predictive performance, at least in short term follow up. BioMed Central 2021-11-21 /pmc/articles/PMC8606093/ /pubmed/34802441 http://dx.doi.org/10.1186/s12947-021-00267-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Poorzand, Hoorak
Tayyebi, Mohammad
Hosseini, Sara
Bakavoli, Alireza Heidari
Keihanian, Faeze
Jarahi, Lida
Hamadanchi, Ali
Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography?
title Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography?
title_full Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography?
title_fullStr Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography?
title_full_unstemmed Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography?
title_short Predictors of worsening TR severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography?
title_sort predictors of worsening tr severity after right ventricular lead placement: any added value by post-procedural fluoroscopy versus three –dimensional echocardiography?
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606093/
https://www.ncbi.nlm.nih.gov/pubmed/34802441
http://dx.doi.org/10.1186/s12947-021-00267-w
work_keys_str_mv AT poorzandhoorak predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography
AT tayyebimohammad predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography
AT hosseinisara predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography
AT bakavolialirezaheidari predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography
AT keihanianfaeze predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography
AT jarahilida predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography
AT hamadanchiali predictorsofworseningtrseverityafterrightventricularleadplacementanyaddedvaluebypostproceduralfluoroscopyversusthreedimensionalechocardiography