Cargando…

Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI

PURPOSE: Our purpose was to evaluate intra-prostatic cancer volumes for salvage radiotherapy in men with recurrent prostate cancer confined to the prostate post-primary radiotherapy using mpMRI and 18F-DCFPyL PET/CT (PET). METHODS: Men with biochemical failure post-primary radiotherapy were enrolled...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Wei, Fakir, Hatim, Randhawa, Gurpreet, Alfano, Ryan, Corkum, Mark, Kassam, Zahra, Rachinsky, Irina, Chung, Hans T., Chung, Peter, Loblaw, Andrew, Morton, Gerard, Sexton, Tracy, Kapoor, Anil, Ward, Aaron, Zukotynski, Katherine, Emmett, Louise, Bauman, Glenn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606298/
https://www.ncbi.nlm.nih.gov/pubmed/34841094
http://dx.doi.org/10.1016/j.ctro.2021.11.006
_version_ 1784602316061540352
author Liu, Wei
Fakir, Hatim
Randhawa, Gurpreet
Alfano, Ryan
Corkum, Mark
Kassam, Zahra
Rachinsky, Irina
Chung, Hans T.
Chung, Peter
Loblaw, Andrew
Morton, Gerard
Sexton, Tracy
Kapoor, Anil
Ward, Aaron
Zukotynski, Katherine
Emmett, Louise
Bauman, Glenn
author_facet Liu, Wei
Fakir, Hatim
Randhawa, Gurpreet
Alfano, Ryan
Corkum, Mark
Kassam, Zahra
Rachinsky, Irina
Chung, Hans T.
Chung, Peter
Loblaw, Andrew
Morton, Gerard
Sexton, Tracy
Kapoor, Anil
Ward, Aaron
Zukotynski, Katherine
Emmett, Louise
Bauman, Glenn
author_sort Liu, Wei
collection PubMed
description PURPOSE: Our purpose was to evaluate intra-prostatic cancer volumes for salvage radiotherapy in men with recurrent prostate cancer confined to the prostate post-primary radiotherapy using mpMRI and 18F-DCFPyL PET/CT (PET). METHODS: Men with biochemical failure post-primary radiotherapy were enrolled in a multi-centre trial investigating mpMRI and PET. All men with isolated intra-prostatic recurrence are included in this secondary analysis. The intra-prostatic gross tumour volume (GTV) was manually delineated on mpMRI and was also delineated on PET using three methods: 1. manually, 2. using a 30% threshold of maximum intra-prostatic standard uptake value (SUVmax), and 3. using a 67% threshold of this SUVmax. Clinical target volumes (CTV) including expansions on each GTV were generated. Conformity indices were performed between the mpMRI CTV and each PET CTV. Correlation with biopsy and clinical outcomes were performed. RESULTS: Of the 36 men included, 30 (83%) had disease in two quadrants or less using the combination of mpMRI and PET. Mean target volume (union of CTV on mpMRI and CTV manually delineated on PET) was 12.2 cc (49% of prostate gland volume). 12/36 (33%) men had a biopsy. Per-patient sensitivity was 91% for mpMRI and 82% for PET. CONCLUSIONS: mpMRI and PET provide complementary information for delineation of intra-prostatic recurrent disease. Union of CTV on mpMRI and PET is often less than 50% of the prostate, suggesting this imaging could help define a target for focal salvage therapy.
format Online
Article
Text
id pubmed-8606298
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-86062982021-11-26 Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI Liu, Wei Fakir, Hatim Randhawa, Gurpreet Alfano, Ryan Corkum, Mark Kassam, Zahra Rachinsky, Irina Chung, Hans T. Chung, Peter Loblaw, Andrew Morton, Gerard Sexton, Tracy Kapoor, Anil Ward, Aaron Zukotynski, Katherine Emmett, Louise Bauman, Glenn Clin Transl Radiat Oncol Article PURPOSE: Our purpose was to evaluate intra-prostatic cancer volumes for salvage radiotherapy in men with recurrent prostate cancer confined to the prostate post-primary radiotherapy using mpMRI and 18F-DCFPyL PET/CT (PET). METHODS: Men with biochemical failure post-primary radiotherapy were enrolled in a multi-centre trial investigating mpMRI and PET. All men with isolated intra-prostatic recurrence are included in this secondary analysis. The intra-prostatic gross tumour volume (GTV) was manually delineated on mpMRI and was also delineated on PET using three methods: 1. manually, 2. using a 30% threshold of maximum intra-prostatic standard uptake value (SUVmax), and 3. using a 67% threshold of this SUVmax. Clinical target volumes (CTV) including expansions on each GTV were generated. Conformity indices were performed between the mpMRI CTV and each PET CTV. Correlation with biopsy and clinical outcomes were performed. RESULTS: Of the 36 men included, 30 (83%) had disease in two quadrants or less using the combination of mpMRI and PET. Mean target volume (union of CTV on mpMRI and CTV manually delineated on PET) was 12.2 cc (49% of prostate gland volume). 12/36 (33%) men had a biopsy. Per-patient sensitivity was 91% for mpMRI and 82% for PET. CONCLUSIONS: mpMRI and PET provide complementary information for delineation of intra-prostatic recurrent disease. Union of CTV on mpMRI and PET is often less than 50% of the prostate, suggesting this imaging could help define a target for focal salvage therapy. Elsevier 2021-11-14 /pmc/articles/PMC8606298/ /pubmed/34841094 http://dx.doi.org/10.1016/j.ctro.2021.11.006 Text en © 2021 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Liu, Wei
Fakir, Hatim
Randhawa, Gurpreet
Alfano, Ryan
Corkum, Mark
Kassam, Zahra
Rachinsky, Irina
Chung, Hans T.
Chung, Peter
Loblaw, Andrew
Morton, Gerard
Sexton, Tracy
Kapoor, Anil
Ward, Aaron
Zukotynski, Katherine
Emmett, Louise
Bauman, Glenn
Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI
title Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI
title_full Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI
title_fullStr Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI
title_full_unstemmed Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI
title_short Defining radio-recurrent intra-prostatic target volumes using PSMA-targeted PET/CT and multi-parametric MRI
title_sort defining radio-recurrent intra-prostatic target volumes using psma-targeted pet/ct and multi-parametric mri
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606298/
https://www.ncbi.nlm.nih.gov/pubmed/34841094
http://dx.doi.org/10.1016/j.ctro.2021.11.006
work_keys_str_mv AT liuwei definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT fakirhatim definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT randhawagurpreet definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT alfanoryan definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT corkummark definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT kassamzahra definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT rachinskyirina definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT chunghanst definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT chungpeter definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT loblawandrew definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT mortongerard definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT sextontracy definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT kapooranil definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT wardaaron definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT zukotynskikatherine definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT emmettlouise definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri
AT baumanglenn definingradiorecurrentintraprostatictargetvolumesusingpsmatargetedpetctandmultiparametricmri