Cargando…

Comparative Assessment of Heart Rate Variability Obtained via Ambulatory ECG and Polar Heart Rate Monitors in Healthy Cats: A Pilot Study

Chronic exposure to stressful environments can negatively impact cats' health and welfare, affecting behavioral, autonomic, endocrine, and immune function, as with cats in shelters. Low-stress handling practices likely improve shelter cat welfare, but data supporting improved outcomes remain li...

Descripción completa

Detalles Bibliográficos
Autores principales: Grigg, Emma K., Ueda, Yu, Walker, Ashley L., Hart, Lynette A., Simas, Samany, Stern, Joshua A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606523/
https://www.ncbi.nlm.nih.gov/pubmed/34820436
http://dx.doi.org/10.3389/fvets.2021.741583
_version_ 1784602349808910336
author Grigg, Emma K.
Ueda, Yu
Walker, Ashley L.
Hart, Lynette A.
Simas, Samany
Stern, Joshua A.
author_facet Grigg, Emma K.
Ueda, Yu
Walker, Ashley L.
Hart, Lynette A.
Simas, Samany
Stern, Joshua A.
author_sort Grigg, Emma K.
collection PubMed
description Chronic exposure to stressful environments can negatively impact cats' health and welfare, affecting behavioral, autonomic, endocrine, and immune function, as with cats in shelters. Low-stress handling practices likely improve shelter cat welfare, but data supporting improved outcomes remain limited. Cardiac activity, particularly heart rate variability (HRV), is an indicator of stress and emotional state in humans and non-human animals, tracking important body functions associated with stress responsiveness, environmental adaptability, mental, and physical health. HRV studies in cats are limited, involving mainly anesthetized or restrained cats. This pilot study tested the feasibility of obtaining HRV data from unrestrained cats, using a commercially available cardiac monitoring system (Polar H10 with chest strap), compared with data from a traditional ambulatory electrocardiogram. Simultaneous data for the two systems were obtained for five adult cats. Overall, the Polar H10 monitor assessments of HRV were lower than the true HRV assessment by ambulatory ECG, except for SDNN. Correlation between the two systems was weak. Possible reasons for the lack of agreement between the two methods are discussed. At this time, our results do not support the use of Polar H10 heart rate monitors for studies of HRV in cats.
format Online
Article
Text
id pubmed-8606523
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-86065232021-11-23 Comparative Assessment of Heart Rate Variability Obtained via Ambulatory ECG and Polar Heart Rate Monitors in Healthy Cats: A Pilot Study Grigg, Emma K. Ueda, Yu Walker, Ashley L. Hart, Lynette A. Simas, Samany Stern, Joshua A. Front Vet Sci Veterinary Science Chronic exposure to stressful environments can negatively impact cats' health and welfare, affecting behavioral, autonomic, endocrine, and immune function, as with cats in shelters. Low-stress handling practices likely improve shelter cat welfare, but data supporting improved outcomes remain limited. Cardiac activity, particularly heart rate variability (HRV), is an indicator of stress and emotional state in humans and non-human animals, tracking important body functions associated with stress responsiveness, environmental adaptability, mental, and physical health. HRV studies in cats are limited, involving mainly anesthetized or restrained cats. This pilot study tested the feasibility of obtaining HRV data from unrestrained cats, using a commercially available cardiac monitoring system (Polar H10 with chest strap), compared with data from a traditional ambulatory electrocardiogram. Simultaneous data for the two systems were obtained for five adult cats. Overall, the Polar H10 monitor assessments of HRV were lower than the true HRV assessment by ambulatory ECG, except for SDNN. Correlation between the two systems was weak. Possible reasons for the lack of agreement between the two methods are discussed. At this time, our results do not support the use of Polar H10 heart rate monitors for studies of HRV in cats. Frontiers Media S.A. 2021-11-08 /pmc/articles/PMC8606523/ /pubmed/34820436 http://dx.doi.org/10.3389/fvets.2021.741583 Text en Copyright © 2021 Grigg, Ueda, Walker, Hart, Simas and Stern. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Veterinary Science
Grigg, Emma K.
Ueda, Yu
Walker, Ashley L.
Hart, Lynette A.
Simas, Samany
Stern, Joshua A.
Comparative Assessment of Heart Rate Variability Obtained via Ambulatory ECG and Polar Heart Rate Monitors in Healthy Cats: A Pilot Study
title Comparative Assessment of Heart Rate Variability Obtained via Ambulatory ECG and Polar Heart Rate Monitors in Healthy Cats: A Pilot Study
title_full Comparative Assessment of Heart Rate Variability Obtained via Ambulatory ECG and Polar Heart Rate Monitors in Healthy Cats: A Pilot Study
title_fullStr Comparative Assessment of Heart Rate Variability Obtained via Ambulatory ECG and Polar Heart Rate Monitors in Healthy Cats: A Pilot Study
title_full_unstemmed Comparative Assessment of Heart Rate Variability Obtained via Ambulatory ECG and Polar Heart Rate Monitors in Healthy Cats: A Pilot Study
title_short Comparative Assessment of Heart Rate Variability Obtained via Ambulatory ECG and Polar Heart Rate Monitors in Healthy Cats: A Pilot Study
title_sort comparative assessment of heart rate variability obtained via ambulatory ecg and polar heart rate monitors in healthy cats: a pilot study
topic Veterinary Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606523/
https://www.ncbi.nlm.nih.gov/pubmed/34820436
http://dx.doi.org/10.3389/fvets.2021.741583
work_keys_str_mv AT griggemmak comparativeassessmentofheartratevariabilityobtainedviaambulatoryecgandpolarheartratemonitorsinhealthycatsapilotstudy
AT uedayu comparativeassessmentofheartratevariabilityobtainedviaambulatoryecgandpolarheartratemonitorsinhealthycatsapilotstudy
AT walkerashleyl comparativeassessmentofheartratevariabilityobtainedviaambulatoryecgandpolarheartratemonitorsinhealthycatsapilotstudy
AT hartlynettea comparativeassessmentofheartratevariabilityobtainedviaambulatoryecgandpolarheartratemonitorsinhealthycatsapilotstudy
AT simassamany comparativeassessmentofheartratevariabilityobtainedviaambulatoryecgandpolarheartratemonitorsinhealthycatsapilotstudy
AT sternjoshuaa comparativeassessmentofheartratevariabilityobtainedviaambulatoryecgandpolarheartratemonitorsinhealthycatsapilotstudy