Cargando…

Ultrasound guided cannulation of dialysis access

Vascular access is the key part of haemodialysis (HD) treatment, as this is not possible without a functioning access. The use of the arteriovenous fistula (AVF) has fewer complications, lower mortality and fewer hospital admissions compared to central venous catheter (CVC). However, although guidel...

Descripción completa

Detalles Bibliográficos
Autores principales: Iglesias, Ruben, Lodi, Massimo, Rubiella, Carolina, Teresa Parisotto, Maria, Ibeas, Jose
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606623/
https://www.ncbi.nlm.nih.gov/pubmed/34590502
http://dx.doi.org/10.1177/11297298211047328
_version_ 1784602370827616256
author Iglesias, Ruben
Lodi, Massimo
Rubiella, Carolina
Teresa Parisotto, Maria
Ibeas, Jose
author_facet Iglesias, Ruben
Lodi, Massimo
Rubiella, Carolina
Teresa Parisotto, Maria
Ibeas, Jose
author_sort Iglesias, Ruben
collection PubMed
description Vascular access is the key part of haemodialysis (HD) treatment, as this is not possible without a functioning access. The use of the arteriovenous fistula (AVF) has fewer complications, lower mortality and fewer hospital admissions compared to central venous catheter (CVC). However, although guidelines recommend AVF as the access of choice, access-related cannulation complications may lead to greater morbidity. Most guidelines recommend using Doppler ultrasound (DU) to surveil the AVF for HD, but its use must not only be limited to surveillance as it can also be used for needling. Therefore, among those techniques at our disposal today, one of the best tools for AVF needling is Doppler ultrasound (DU). Despite the lack of evidence regarding ultrasound-guided needling of AVF, it is becoming part of our usual practice arsenal in many HD centres. Its use has allowed needling results to improve and the number of complications to be reduced versus traditional ‘blind’ needling. It should be remembered that even though it is very useful for the daily work of dialysis nurses, as in the case of other techniques, it requires adequate, specialised and long-term training to acquire competence in using it. For example, it is important to learn some concepts and terminology that should be known and, at the same time, be highly familiar with different techniques available. Two types of needling techniques are described using US assistance: US-guided needling, where DU is used to make a map of the vessels which can be utilised and to mark the best site to insert the needles once the mapping is done; and real-time US-guided needling, the simultaneous manipulation of the probe and the insertion of the puncture needle through the slice plane of the ultrasound device. Regarding the real-time technique, there are two approaches: out of plane (the probe takes a transversal image of the needle) and in plane (vessel axis aligned with the probe and the needle in the same plane) To ensure successful needling and to maximise reproducibility, especially with tight deadlines and staff resources, nursing staff need to follow some important recommendations that include safety and the use of the method, both for them and the patient. In this way, ultrasound-guided needling becomes a tool with enormous potential utility, but practical training is as important as knowing the technique.
format Online
Article
Text
id pubmed-8606623
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-86066232021-11-23 Ultrasound guided cannulation of dialysis access Iglesias, Ruben Lodi, Massimo Rubiella, Carolina Teresa Parisotto, Maria Ibeas, Jose J Vasc Access Original Research Articles Vascular access is the key part of haemodialysis (HD) treatment, as this is not possible without a functioning access. The use of the arteriovenous fistula (AVF) has fewer complications, lower mortality and fewer hospital admissions compared to central venous catheter (CVC). However, although guidelines recommend AVF as the access of choice, access-related cannulation complications may lead to greater morbidity. Most guidelines recommend using Doppler ultrasound (DU) to surveil the AVF for HD, but its use must not only be limited to surveillance as it can also be used for needling. Therefore, among those techniques at our disposal today, one of the best tools for AVF needling is Doppler ultrasound (DU). Despite the lack of evidence regarding ultrasound-guided needling of AVF, it is becoming part of our usual practice arsenal in many HD centres. Its use has allowed needling results to improve and the number of complications to be reduced versus traditional ‘blind’ needling. It should be remembered that even though it is very useful for the daily work of dialysis nurses, as in the case of other techniques, it requires adequate, specialised and long-term training to acquire competence in using it. For example, it is important to learn some concepts and terminology that should be known and, at the same time, be highly familiar with different techniques available. Two types of needling techniques are described using US assistance: US-guided needling, where DU is used to make a map of the vessels which can be utilised and to mark the best site to insert the needles once the mapping is done; and real-time US-guided needling, the simultaneous manipulation of the probe and the insertion of the puncture needle through the slice plane of the ultrasound device. Regarding the real-time technique, there are two approaches: out of plane (the probe takes a transversal image of the needle) and in plane (vessel axis aligned with the probe and the needle in the same plane) To ensure successful needling and to maximise reproducibility, especially with tight deadlines and staff resources, nursing staff need to follow some important recommendations that include safety and the use of the method, both for them and the patient. In this way, ultrasound-guided needling becomes a tool with enormous potential utility, but practical training is as important as knowing the technique. SAGE Publications 2021-09-30 2021-11 /pmc/articles/PMC8606623/ /pubmed/34590502 http://dx.doi.org/10.1177/11297298211047328 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Research Articles
Iglesias, Ruben
Lodi, Massimo
Rubiella, Carolina
Teresa Parisotto, Maria
Ibeas, Jose
Ultrasound guided cannulation of dialysis access
title Ultrasound guided cannulation of dialysis access
title_full Ultrasound guided cannulation of dialysis access
title_fullStr Ultrasound guided cannulation of dialysis access
title_full_unstemmed Ultrasound guided cannulation of dialysis access
title_short Ultrasound guided cannulation of dialysis access
title_sort ultrasound guided cannulation of dialysis access
topic Original Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606623/
https://www.ncbi.nlm.nih.gov/pubmed/34590502
http://dx.doi.org/10.1177/11297298211047328
work_keys_str_mv AT iglesiasruben ultrasoundguidedcannulationofdialysisaccess
AT lodimassimo ultrasoundguidedcannulationofdialysisaccess
AT rubiellacarolina ultrasoundguidedcannulationofdialysisaccess
AT teresaparisottomaria ultrasoundguidedcannulationofdialysisaccess
AT ibeasjose ultrasoundguidedcannulationofdialysisaccess