Cardiac Dose Control and Optimization Strategy for Left Breast Cancer Radiotherapy With Non-Uniform VMAT Technology
Purpose: A novel in-house technology “Non-Uniform VMAT (NU-VMAT)” was developed for automated cardiac dose reduction and treatment planning optimization in the left breast radiotherapy. Methods: The NU-VMAT model based on I(GM) (gantry MLC Movement coefficient index) was established to optimize the...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606722/ https://www.ncbi.nlm.nih.gov/pubmed/34806481 http://dx.doi.org/10.1177/15330338211053752 |
_version_ | 1784602395319205888 |
---|---|
author | Qiu, Jianjian Zhang, Shujun Lv, Bo Zheng, Xiangpeng |
author_facet | Qiu, Jianjian Zhang, Shujun Lv, Bo Zheng, Xiangpeng |
author_sort | Qiu, Jianjian |
collection | PubMed |
description | Purpose: A novel in-house technology “Non-Uniform VMAT (NU-VMAT)” was developed for automated cardiac dose reduction and treatment planning optimization in the left breast radiotherapy. Methods: The NU-VMAT model based on I(GM) (gantry MLC Movement coefficient index) was established to optimize the volumetric modulated arc therapy (VMAT) MLC movement and modulation intensity in certain gantry angles. The ESAPI embedded in Eclipse® was employed to connect TPS and the optimization program via I/O relevant DICOM RT files. The adjuvant whole-breast radiotherapy of 14 patients with left breast cancer was replanned using our NU-VMAT technology in comparison with VMAT and IMRT technology. Dosimetric parameters including D(1%), D(99%), and D(mean) of PTV, V(5), V(10), and V(20) of ipisilateral lung, V(5), D(20), D(30), and D(mean) of heart, monitor units (MUs), and delivery time derived from IMRT, VMAT, and NU-VMAT plans were evaluated for plan quality and delivery efficiency. The quality assurance (QA) was conducted using both point-dose and planar-dose measurements for all treatment plans. Results: The I(GM−NU−VMAT) curves with plan optimization (range from 50% to 147%) were converged more significantly than I(GM)-(VMAT) curves (range from 0% to 297%). The dose distribution requirements of the target and normal tissues could be met using IMRT, VMAT, or NU-VMAT; the lowest D(mean) was achieved in NU-VMAT plans (5.38 ± 0.46 Gy vs 5.63 ± 0.61 Gy in IMRT and 7.95 ± 0.52 Gy in VMAT plans). Statistically significant differences were found in terms of delivery time and MU when comparing IMRT with VMAT and NU-VMAT plans (P < .05). In comparison with IMRT plans, the MU and delivery time in NU-VMAT plans dramatically decreased by 69.8% and 28.4%, respectively. Moreover, NU-VMAT plans showed a high gamma passing rate (96.5% ± 1.11) in plane dose verification and minimal dose difference (2.4% ± 0.19) in point absolute dose verification. Conclusion: Our non-uniform VMAT facilitated the treatment strategy optimization for left breast cancer radiotherapy with dosimetric advantage in cardiac dose reduction and delivery efficiency in comparison with the conventional VMAT and IMRT. |
format | Online Article Text |
id | pubmed-8606722 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-86067222021-11-23 Cardiac Dose Control and Optimization Strategy for Left Breast Cancer Radiotherapy With Non-Uniform VMAT Technology Qiu, Jianjian Zhang, Shujun Lv, Bo Zheng, Xiangpeng Technol Cancer Res Treat Original Article Purpose: A novel in-house technology “Non-Uniform VMAT (NU-VMAT)” was developed for automated cardiac dose reduction and treatment planning optimization in the left breast radiotherapy. Methods: The NU-VMAT model based on I(GM) (gantry MLC Movement coefficient index) was established to optimize the volumetric modulated arc therapy (VMAT) MLC movement and modulation intensity in certain gantry angles. The ESAPI embedded in Eclipse® was employed to connect TPS and the optimization program via I/O relevant DICOM RT files. The adjuvant whole-breast radiotherapy of 14 patients with left breast cancer was replanned using our NU-VMAT technology in comparison with VMAT and IMRT technology. Dosimetric parameters including D(1%), D(99%), and D(mean) of PTV, V(5), V(10), and V(20) of ipisilateral lung, V(5), D(20), D(30), and D(mean) of heart, monitor units (MUs), and delivery time derived from IMRT, VMAT, and NU-VMAT plans were evaluated for plan quality and delivery efficiency. The quality assurance (QA) was conducted using both point-dose and planar-dose measurements for all treatment plans. Results: The I(GM−NU−VMAT) curves with plan optimization (range from 50% to 147%) were converged more significantly than I(GM)-(VMAT) curves (range from 0% to 297%). The dose distribution requirements of the target and normal tissues could be met using IMRT, VMAT, or NU-VMAT; the lowest D(mean) was achieved in NU-VMAT plans (5.38 ± 0.46 Gy vs 5.63 ± 0.61 Gy in IMRT and 7.95 ± 0.52 Gy in VMAT plans). Statistically significant differences were found in terms of delivery time and MU when comparing IMRT with VMAT and NU-VMAT plans (P < .05). In comparison with IMRT plans, the MU and delivery time in NU-VMAT plans dramatically decreased by 69.8% and 28.4%, respectively. Moreover, NU-VMAT plans showed a high gamma passing rate (96.5% ± 1.11) in plane dose verification and minimal dose difference (2.4% ± 0.19) in point absolute dose verification. Conclusion: Our non-uniform VMAT facilitated the treatment strategy optimization for left breast cancer radiotherapy with dosimetric advantage in cardiac dose reduction and delivery efficiency in comparison with the conventional VMAT and IMRT. SAGE Publications 2021-11-20 /pmc/articles/PMC8606722/ /pubmed/34806481 http://dx.doi.org/10.1177/15330338211053752 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Qiu, Jianjian Zhang, Shujun Lv, Bo Zheng, Xiangpeng Cardiac Dose Control and Optimization Strategy for Left Breast Cancer Radiotherapy With Non-Uniform VMAT Technology |
title | Cardiac Dose Control and Optimization Strategy for Left Breast Cancer Radiotherapy With Non-Uniform VMAT Technology |
title_full | Cardiac Dose Control and Optimization Strategy for Left Breast Cancer Radiotherapy With Non-Uniform VMAT Technology |
title_fullStr | Cardiac Dose Control and Optimization Strategy for Left Breast Cancer Radiotherapy With Non-Uniform VMAT Technology |
title_full_unstemmed | Cardiac Dose Control and Optimization Strategy for Left Breast Cancer Radiotherapy With Non-Uniform VMAT Technology |
title_short | Cardiac Dose Control and Optimization Strategy for Left Breast Cancer Radiotherapy With Non-Uniform VMAT Technology |
title_sort | cardiac dose control and optimization strategy for left breast cancer radiotherapy with non-uniform vmat technology |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606722/ https://www.ncbi.nlm.nih.gov/pubmed/34806481 http://dx.doi.org/10.1177/15330338211053752 |
work_keys_str_mv | AT qiujianjian cardiacdosecontrolandoptimizationstrategyforleftbreastcancerradiotherapywithnonuniformvmattechnology AT zhangshujun cardiacdosecontrolandoptimizationstrategyforleftbreastcancerradiotherapywithnonuniformvmattechnology AT lvbo cardiacdosecontrolandoptimizationstrategyforleftbreastcancerradiotherapywithnonuniformvmattechnology AT zhengxiangpeng cardiacdosecontrolandoptimizationstrategyforleftbreastcancerradiotherapywithnonuniformvmattechnology |