Cargando…
Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT
In evolutionary biomechanics, musculoskeletal computer models of extant and extinct taxa are often used to estimate joint range of motion (ROM) and muscle moment arms (MMAs), two parameters which form the basis of functional inferences. However, relatively few experimental studies have been performe...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606742/ https://www.ncbi.nlm.nih.gov/pubmed/34820362 http://dx.doi.org/10.3389/fbioe.2021.751518 |
_version_ | 1784602400273727488 |
---|---|
author | Regnault, Sophie Fahn-Lai, Philip Pierce, Stephanie E. |
author_facet | Regnault, Sophie Fahn-Lai, Philip Pierce, Stephanie E. |
author_sort | Regnault, Sophie |
collection | PubMed |
description | In evolutionary biomechanics, musculoskeletal computer models of extant and extinct taxa are often used to estimate joint range of motion (ROM) and muscle moment arms (MMAs), two parameters which form the basis of functional inferences. However, relatively few experimental studies have been performed to validate model outputs. Previously, we built a model of the short-beaked echidna (Tachyglossus aculeatus) forelimb using a traditional modelling workflow, and in this study we evaluate its behaviour and outputs using experimental data. The echidna is an unusual animal representing an edge-case for model validation: it uses a unique form of sprawling locomotion, and possesses a suite of derived anatomical features, in addition to other features reminiscent of extinct early relatives of mammals. Here we use diffusible iodine-based contrast-enhanced computed tomography (diceCT) alongside digital and traditional dissection to evaluate muscle attachments, modelled muscle paths, and the effects of model alterations on the MMA outputs. We use X-ray Reconstruction of Moving Morphology (XROMM) to compare ex vivo joint ROM to model estimates based on osteological limits predicted via single-axis rotation, and to calculate experimental MMAs from implanted muscles using a novel geometric method. We also add additional levels of model detail, in the form of muscle architecture, to evaluate how muscle torque might alter the inferences made from MMAs alone, as is typical in evolutionary studies. Our study identifies several key findings that can be applied to future models. 1) A light-touch approach to model building can generate reasonably accurate muscle paths, and small alterations in attachment site seem to have minimal effects on model output. 2) Simultaneous movement through multiple degrees of freedom, including rotations and translation at joints, are necessary to ensure full joint ROM is captured; however, single-axis ROM can provide a reasonable approximation of mobility depending on the modelling objectives. 3) Our geometric method of calculating MMAs is consistent with model-predicted MMAs calculated via partial velocity, and is a potentially useful tool for others to create and validate musculoskeletal models. 4) Inclusion of muscle architecture data can change some functional inferences, but in many cases reinforced conclusions based on MMA alone. |
format | Online Article Text |
id | pubmed-8606742 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-86067422021-11-23 Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT Regnault, Sophie Fahn-Lai, Philip Pierce, Stephanie E. Front Bioeng Biotechnol Bioengineering and Biotechnology In evolutionary biomechanics, musculoskeletal computer models of extant and extinct taxa are often used to estimate joint range of motion (ROM) and muscle moment arms (MMAs), two parameters which form the basis of functional inferences. However, relatively few experimental studies have been performed to validate model outputs. Previously, we built a model of the short-beaked echidna (Tachyglossus aculeatus) forelimb using a traditional modelling workflow, and in this study we evaluate its behaviour and outputs using experimental data. The echidna is an unusual animal representing an edge-case for model validation: it uses a unique form of sprawling locomotion, and possesses a suite of derived anatomical features, in addition to other features reminiscent of extinct early relatives of mammals. Here we use diffusible iodine-based contrast-enhanced computed tomography (diceCT) alongside digital and traditional dissection to evaluate muscle attachments, modelled muscle paths, and the effects of model alterations on the MMA outputs. We use X-ray Reconstruction of Moving Morphology (XROMM) to compare ex vivo joint ROM to model estimates based on osteological limits predicted via single-axis rotation, and to calculate experimental MMAs from implanted muscles using a novel geometric method. We also add additional levels of model detail, in the form of muscle architecture, to evaluate how muscle torque might alter the inferences made from MMAs alone, as is typical in evolutionary studies. Our study identifies several key findings that can be applied to future models. 1) A light-touch approach to model building can generate reasonably accurate muscle paths, and small alterations in attachment site seem to have minimal effects on model output. 2) Simultaneous movement through multiple degrees of freedom, including rotations and translation at joints, are necessary to ensure full joint ROM is captured; however, single-axis ROM can provide a reasonable approximation of mobility depending on the modelling objectives. 3) Our geometric method of calculating MMAs is consistent with model-predicted MMAs calculated via partial velocity, and is a potentially useful tool for others to create and validate musculoskeletal models. 4) Inclusion of muscle architecture data can change some functional inferences, but in many cases reinforced conclusions based on MMA alone. Frontiers Media S.A. 2021-11-08 /pmc/articles/PMC8606742/ /pubmed/34820362 http://dx.doi.org/10.3389/fbioe.2021.751518 Text en Copyright © 2021 Regnault, Fahn-Lai and Pierce. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Regnault, Sophie Fahn-Lai, Philip Pierce, Stephanie E. Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT |
title | Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT |
title_full | Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT |
title_fullStr | Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT |
title_full_unstemmed | Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT |
title_short | Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT |
title_sort | validation of an echidna forelimb musculoskeletal model using xromm and dicect |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606742/ https://www.ncbi.nlm.nih.gov/pubmed/34820362 http://dx.doi.org/10.3389/fbioe.2021.751518 |
work_keys_str_mv | AT regnaultsophie validationofanechidnaforelimbmusculoskeletalmodelusingxrommanddicect AT fahnlaiphilip validationofanechidnaforelimbmusculoskeletalmodelusingxrommanddicect AT piercestephaniee validationofanechidnaforelimbmusculoskeletalmodelusingxrommanddicect |