Cargando…

Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT

In evolutionary biomechanics, musculoskeletal computer models of extant and extinct taxa are often used to estimate joint range of motion (ROM) and muscle moment arms (MMAs), two parameters which form the basis of functional inferences. However, relatively few experimental studies have been performe...

Descripción completa

Detalles Bibliográficos
Autores principales: Regnault, Sophie, Fahn-Lai, Philip, Pierce, Stephanie E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606742/
https://www.ncbi.nlm.nih.gov/pubmed/34820362
http://dx.doi.org/10.3389/fbioe.2021.751518
_version_ 1784602400273727488
author Regnault, Sophie
Fahn-Lai, Philip
Pierce, Stephanie E.
author_facet Regnault, Sophie
Fahn-Lai, Philip
Pierce, Stephanie E.
author_sort Regnault, Sophie
collection PubMed
description In evolutionary biomechanics, musculoskeletal computer models of extant and extinct taxa are often used to estimate joint range of motion (ROM) and muscle moment arms (MMAs), two parameters which form the basis of functional inferences. However, relatively few experimental studies have been performed to validate model outputs. Previously, we built a model of the short-beaked echidna (Tachyglossus aculeatus) forelimb using a traditional modelling workflow, and in this study we evaluate its behaviour and outputs using experimental data. The echidna is an unusual animal representing an edge-case for model validation: it uses a unique form of sprawling locomotion, and possesses a suite of derived anatomical features, in addition to other features reminiscent of extinct early relatives of mammals. Here we use diffusible iodine-based contrast-enhanced computed tomography (diceCT) alongside digital and traditional dissection to evaluate muscle attachments, modelled muscle paths, and the effects of model alterations on the MMA outputs. We use X-ray Reconstruction of Moving Morphology (XROMM) to compare ex vivo joint ROM to model estimates based on osteological limits predicted via single-axis rotation, and to calculate experimental MMAs from implanted muscles using a novel geometric method. We also add additional levels of model detail, in the form of muscle architecture, to evaluate how muscle torque might alter the inferences made from MMAs alone, as is typical in evolutionary studies. Our study identifies several key findings that can be applied to future models. 1) A light-touch approach to model building can generate reasonably accurate muscle paths, and small alterations in attachment site seem to have minimal effects on model output. 2) Simultaneous movement through multiple degrees of freedom, including rotations and translation at joints, are necessary to ensure full joint ROM is captured; however, single-axis ROM can provide a reasonable approximation of mobility depending on the modelling objectives. 3) Our geometric method of calculating MMAs is consistent with model-predicted MMAs calculated via partial velocity, and is a potentially useful tool for others to create and validate musculoskeletal models. 4) Inclusion of muscle architecture data can change some functional inferences, but in many cases reinforced conclusions based on MMA alone.
format Online
Article
Text
id pubmed-8606742
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-86067422021-11-23 Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT Regnault, Sophie Fahn-Lai, Philip Pierce, Stephanie E. Front Bioeng Biotechnol Bioengineering and Biotechnology In evolutionary biomechanics, musculoskeletal computer models of extant and extinct taxa are often used to estimate joint range of motion (ROM) and muscle moment arms (MMAs), two parameters which form the basis of functional inferences. However, relatively few experimental studies have been performed to validate model outputs. Previously, we built a model of the short-beaked echidna (Tachyglossus aculeatus) forelimb using a traditional modelling workflow, and in this study we evaluate its behaviour and outputs using experimental data. The echidna is an unusual animal representing an edge-case for model validation: it uses a unique form of sprawling locomotion, and possesses a suite of derived anatomical features, in addition to other features reminiscent of extinct early relatives of mammals. Here we use diffusible iodine-based contrast-enhanced computed tomography (diceCT) alongside digital and traditional dissection to evaluate muscle attachments, modelled muscle paths, and the effects of model alterations on the MMA outputs. We use X-ray Reconstruction of Moving Morphology (XROMM) to compare ex vivo joint ROM to model estimates based on osteological limits predicted via single-axis rotation, and to calculate experimental MMAs from implanted muscles using a novel geometric method. We also add additional levels of model detail, in the form of muscle architecture, to evaluate how muscle torque might alter the inferences made from MMAs alone, as is typical in evolutionary studies. Our study identifies several key findings that can be applied to future models. 1) A light-touch approach to model building can generate reasonably accurate muscle paths, and small alterations in attachment site seem to have minimal effects on model output. 2) Simultaneous movement through multiple degrees of freedom, including rotations and translation at joints, are necessary to ensure full joint ROM is captured; however, single-axis ROM can provide a reasonable approximation of mobility depending on the modelling objectives. 3) Our geometric method of calculating MMAs is consistent with model-predicted MMAs calculated via partial velocity, and is a potentially useful tool for others to create and validate musculoskeletal models. 4) Inclusion of muscle architecture data can change some functional inferences, but in many cases reinforced conclusions based on MMA alone. Frontiers Media S.A. 2021-11-08 /pmc/articles/PMC8606742/ /pubmed/34820362 http://dx.doi.org/10.3389/fbioe.2021.751518 Text en Copyright © 2021 Regnault, Fahn-Lai and Pierce. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Regnault, Sophie
Fahn-Lai, Philip
Pierce, Stephanie E.
Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT
title Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT
title_full Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT
title_fullStr Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT
title_full_unstemmed Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT
title_short Validation of an Echidna Forelimb Musculoskeletal Model Using XROMM and diceCT
title_sort validation of an echidna forelimb musculoskeletal model using xromm and dicect
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606742/
https://www.ncbi.nlm.nih.gov/pubmed/34820362
http://dx.doi.org/10.3389/fbioe.2021.751518
work_keys_str_mv AT regnaultsophie validationofanechidnaforelimbmusculoskeletalmodelusingxrommanddicect
AT fahnlaiphilip validationofanechidnaforelimbmusculoskeletalmodelusingxrommanddicect
AT piercestephaniee validationofanechidnaforelimbmusculoskeletalmodelusingxrommanddicect