Cargando…
Hyperemic myocardial blood flow in patients with atrial fibrillation before and after catheter ablation: A dynamic stress CT perfusion study
BACKGROUND: Atrial fibrillation (AF) patients without coronary artery stenosis often show clinical evidence of ischemia. However myocardial perfusion in AF patients has been poorly studied. The purposes of this study were to investigate altered hyperemic myocardial blood flow (MBF) in patients with...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606864/ https://www.ncbi.nlm.nih.gov/pubmed/34806340 http://dx.doi.org/10.14814/phy2.15123 |
_version_ | 1784602428495101952 |
---|---|
author | Takafuji, Masafumi Kitagawa, Kakuya Nakamura, Satoshi Kokawa, Takanori Kagawa, Yoshihiko Fujita, Satoshi Fukuma, Tomoyuki Fujii, Eitaro Dohi, Kaoru Sakuma, Hajime |
author_facet | Takafuji, Masafumi Kitagawa, Kakuya Nakamura, Satoshi Kokawa, Takanori Kagawa, Yoshihiko Fujita, Satoshi Fukuma, Tomoyuki Fujii, Eitaro Dohi, Kaoru Sakuma, Hajime |
author_sort | Takafuji, Masafumi |
collection | PubMed |
description | BACKGROUND: Atrial fibrillation (AF) patients without coronary artery stenosis often show clinical evidence of ischemia. However myocardial perfusion in AF patients has been poorly studied. The purposes of this study were to investigate altered hyperemic myocardial blood flow (MBF) in patients with AF compared with risk‐matched controls in sinus rhythm (SR), and to evaluate hyperemic MBF before and after catheter ablation using dynamic CT perfusion. METHODS: Hyperemic MBF was quantified in 87 patients with AF (44 paroxysmal, 43 persistent) scheduled for catheter ablation using dynamic CT perfusion, and compared with hyperemic MBF in 87 risk‐matched controls in SR. Follow‐up CT after ablation was performed in 49 AF patients. RESULTS: Prior to ablation, hyperemic MBF of patients in AF during the CT (1.29 ± 0.34 ml/mg/min) was significantly lower than in patients in SR (1.49 ± 0.26 ml/g/min, p = 0.002) or matched controls (1.65 ± 0.32 ml/g/min, p < 0.001); no significant difference was seen between patients in SR during the CT and matched controls (vs. 1.50 ± 0.31 ml/g/min, p = 0.815). In patients in AF during the pre‐ablation CT (n = 24), hyperemic MBF significantly increased after ablation from 1.30 ± 0.35 to 1.53 ± 0.17 ml/g/min (p = 0.004); whereas in patients in SR during the pre‐ablation CT (n = 25), hyperemic MBF did not change significantly after ablation (from 1.46 ± 0.26 to 1.49 ± 0.27 ml/g/min, p = 0.499). CONCLUSION: In the current study using stress perfusion CT, hyperemic MBF in patients with AF during pre‐ablation CT was significantly lower than that in risk‐matched controls, and improved significantly after restoration of SR by catheter ablation, indicating that MBF abnormalities in AF patients are caused primarily by AF itself. |
format | Online Article Text |
id | pubmed-8606864 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-86068642021-11-29 Hyperemic myocardial blood flow in patients with atrial fibrillation before and after catheter ablation: A dynamic stress CT perfusion study Takafuji, Masafumi Kitagawa, Kakuya Nakamura, Satoshi Kokawa, Takanori Kagawa, Yoshihiko Fujita, Satoshi Fukuma, Tomoyuki Fujii, Eitaro Dohi, Kaoru Sakuma, Hajime Physiol Rep Original Articles BACKGROUND: Atrial fibrillation (AF) patients without coronary artery stenosis often show clinical evidence of ischemia. However myocardial perfusion in AF patients has been poorly studied. The purposes of this study were to investigate altered hyperemic myocardial blood flow (MBF) in patients with AF compared with risk‐matched controls in sinus rhythm (SR), and to evaluate hyperemic MBF before and after catheter ablation using dynamic CT perfusion. METHODS: Hyperemic MBF was quantified in 87 patients with AF (44 paroxysmal, 43 persistent) scheduled for catheter ablation using dynamic CT perfusion, and compared with hyperemic MBF in 87 risk‐matched controls in SR. Follow‐up CT after ablation was performed in 49 AF patients. RESULTS: Prior to ablation, hyperemic MBF of patients in AF during the CT (1.29 ± 0.34 ml/mg/min) was significantly lower than in patients in SR (1.49 ± 0.26 ml/g/min, p = 0.002) or matched controls (1.65 ± 0.32 ml/g/min, p < 0.001); no significant difference was seen between patients in SR during the CT and matched controls (vs. 1.50 ± 0.31 ml/g/min, p = 0.815). In patients in AF during the pre‐ablation CT (n = 24), hyperemic MBF significantly increased after ablation from 1.30 ± 0.35 to 1.53 ± 0.17 ml/g/min (p = 0.004); whereas in patients in SR during the pre‐ablation CT (n = 25), hyperemic MBF did not change significantly after ablation (from 1.46 ± 0.26 to 1.49 ± 0.27 ml/g/min, p = 0.499). CONCLUSION: In the current study using stress perfusion CT, hyperemic MBF in patients with AF during pre‐ablation CT was significantly lower than that in risk‐matched controls, and improved significantly after restoration of SR by catheter ablation, indicating that MBF abnormalities in AF patients are caused primarily by AF itself. John Wiley and Sons Inc. 2021-11-21 /pmc/articles/PMC8606864/ /pubmed/34806340 http://dx.doi.org/10.14814/phy2.15123 Text en © 2021 The Authors. Physiological Reports published by Wiley Periodicals LLC on behalf of The Physiological Society and the American Physiological Society https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles Takafuji, Masafumi Kitagawa, Kakuya Nakamura, Satoshi Kokawa, Takanori Kagawa, Yoshihiko Fujita, Satoshi Fukuma, Tomoyuki Fujii, Eitaro Dohi, Kaoru Sakuma, Hajime Hyperemic myocardial blood flow in patients with atrial fibrillation before and after catheter ablation: A dynamic stress CT perfusion study |
title | Hyperemic myocardial blood flow in patients with atrial fibrillation before and after catheter ablation: A dynamic stress CT perfusion study |
title_full | Hyperemic myocardial blood flow in patients with atrial fibrillation before and after catheter ablation: A dynamic stress CT perfusion study |
title_fullStr | Hyperemic myocardial blood flow in patients with atrial fibrillation before and after catheter ablation: A dynamic stress CT perfusion study |
title_full_unstemmed | Hyperemic myocardial blood flow in patients with atrial fibrillation before and after catheter ablation: A dynamic stress CT perfusion study |
title_short | Hyperemic myocardial blood flow in patients with atrial fibrillation before and after catheter ablation: A dynamic stress CT perfusion study |
title_sort | hyperemic myocardial blood flow in patients with atrial fibrillation before and after catheter ablation: a dynamic stress ct perfusion study |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8606864/ https://www.ncbi.nlm.nih.gov/pubmed/34806340 http://dx.doi.org/10.14814/phy2.15123 |
work_keys_str_mv | AT takafujimasafumi hyperemicmyocardialbloodflowinpatientswithatrialfibrillationbeforeandaftercatheterablationadynamicstressctperfusionstudy AT kitagawakakuya hyperemicmyocardialbloodflowinpatientswithatrialfibrillationbeforeandaftercatheterablationadynamicstressctperfusionstudy AT nakamurasatoshi hyperemicmyocardialbloodflowinpatientswithatrialfibrillationbeforeandaftercatheterablationadynamicstressctperfusionstudy AT kokawatakanori hyperemicmyocardialbloodflowinpatientswithatrialfibrillationbeforeandaftercatheterablationadynamicstressctperfusionstudy AT kagawayoshihiko hyperemicmyocardialbloodflowinpatientswithatrialfibrillationbeforeandaftercatheterablationadynamicstressctperfusionstudy AT fujitasatoshi hyperemicmyocardialbloodflowinpatientswithatrialfibrillationbeforeandaftercatheterablationadynamicstressctperfusionstudy AT fukumatomoyuki hyperemicmyocardialbloodflowinpatientswithatrialfibrillationbeforeandaftercatheterablationadynamicstressctperfusionstudy AT fujiieitaro hyperemicmyocardialbloodflowinpatientswithatrialfibrillationbeforeandaftercatheterablationadynamicstressctperfusionstudy AT dohikaoru hyperemicmyocardialbloodflowinpatientswithatrialfibrillationbeforeandaftercatheterablationadynamicstressctperfusionstudy AT sakumahajime hyperemicmyocardialbloodflowinpatientswithatrialfibrillationbeforeandaftercatheterablationadynamicstressctperfusionstudy |