Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study
OBJECTIVE: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. METHODS: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodon...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Association of Orthodontists
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8607117/ https://www.ncbi.nlm.nih.gov/pubmed/34803026 http://dx.doi.org/10.4041/kjod.2021.51.6.375 |
_version_ | 1784602491591065600 |
---|---|
author | Park, Jae-Hyun Choi, Jin-Young Kim, Seong-Hun Kim, Su-Jung Lee, Kee-Joon Nelson, Gerald |
author_facet | Park, Jae-Hyun Choi, Jin-Young Kim, Seong-Hun Kim, Su-Jung Lee, Kee-Joon Nelson, Gerald |
author_sort | Park, Jae-Hyun |
collection | PubMed |
description | OBJECTIVE: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. METHODS: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodontic treatment. Bracket position errors from each of the 40 arches were analyzed quantitatively via 3D digital superimposition (best-fit algorithm) of the virtual bracket and actual bracket after indirect bonding, after accounting for possible variables that may affect accuracy, such as crowding and presence of the resin base. RESULTS: The device could transfer the bracket accurately to the desired position of the patient’s dentition within a clinically acceptable range of ± 0.05 mm and 2.0° for linear and angular measurements, respectively. The average linear measurements ranged from 0.029 to 0.101 mm. Among the angular measurements, rotation values showed the least deviation and ranged from 0.396° to 0.623°. Directional bias was pronounced in the vertical direction, and many brackets were bonded toward the occlusal surface. However, no statistical difference was found for the three angular measurement values (torque, angulation, and rotation) in any of the groups classified according to crowding. When the teeth were moderately crowded, the mesio-distal, bucco-lingual, and rotation measurement values were affected by the presence of the resin base. CONCLUSIONS: The characteristics of the CAD/CAM one-piece jig system were demonstrated according to the influencing factors, and the transfer accuracy was verified to be within a clinically acceptable level for the indirect bracket bonding of anterior teeth. |
format | Online Article Text |
id | pubmed-8607117 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Korean Association of Orthodontists |
record_format | MEDLINE/PubMed |
spelling | pubmed-86071172021-12-06 Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study Park, Jae-Hyun Choi, Jin-Young Kim, Seong-Hun Kim, Su-Jung Lee, Kee-Joon Nelson, Gerald Korean J Orthod Original Article OBJECTIVE: To evaluate the accuracy of a one-piece bracket jig system fabricated using computer-aided design and manufacturing (CAD/CAM) by employing three-dimensional (3D) digital superimposition. METHODS: This in vitro study included 226 anterior teeth selected from 20 patients undergoing orthodontic treatment. Bracket position errors from each of the 40 arches were analyzed quantitatively via 3D digital superimposition (best-fit algorithm) of the virtual bracket and actual bracket after indirect bonding, after accounting for possible variables that may affect accuracy, such as crowding and presence of the resin base. RESULTS: The device could transfer the bracket accurately to the desired position of the patient’s dentition within a clinically acceptable range of ± 0.05 mm and 2.0° for linear and angular measurements, respectively. The average linear measurements ranged from 0.029 to 0.101 mm. Among the angular measurements, rotation values showed the least deviation and ranged from 0.396° to 0.623°. Directional bias was pronounced in the vertical direction, and many brackets were bonded toward the occlusal surface. However, no statistical difference was found for the three angular measurement values (torque, angulation, and rotation) in any of the groups classified according to crowding. When the teeth were moderately crowded, the mesio-distal, bucco-lingual, and rotation measurement values were affected by the presence of the resin base. CONCLUSIONS: The characteristics of the CAD/CAM one-piece jig system were demonstrated according to the influencing factors, and the transfer accuracy was verified to be within a clinically acceptable level for the indirect bracket bonding of anterior teeth. Korean Association of Orthodontists 2021-11-25 2021-11-25 /pmc/articles/PMC8607117/ /pubmed/34803026 http://dx.doi.org/10.4041/kjod.2021.51.6.375 Text en © 2021 The Korean Association of Orthodontists. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Park, Jae-Hyun Choi, Jin-Young Kim, Seong-Hun Kim, Su-Jung Lee, Kee-Joon Nelson, Gerald Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study |
title | Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study |
title_full | Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study |
title_fullStr | Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study |
title_full_unstemmed | Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study |
title_short | Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study |
title_sort | three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: an in vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8607117/ https://www.ncbi.nlm.nih.gov/pubmed/34803026 http://dx.doi.org/10.4041/kjod.2021.51.6.375 |
work_keys_str_mv | AT parkjaehyun threedimensionalevaluationofthetransferaccuracyofabracketjigfabricatedusingcomputeraideddesignandmanufacturingtotheanteriordentitionaninvitrostudy AT choijinyoung threedimensionalevaluationofthetransferaccuracyofabracketjigfabricatedusingcomputeraideddesignandmanufacturingtotheanteriordentitionaninvitrostudy AT kimseonghun threedimensionalevaluationofthetransferaccuracyofabracketjigfabricatedusingcomputeraideddesignandmanufacturingtotheanteriordentitionaninvitrostudy AT kimsujung threedimensionalevaluationofthetransferaccuracyofabracketjigfabricatedusingcomputeraideddesignandmanufacturingtotheanteriordentitionaninvitrostudy AT leekeejoon threedimensionalevaluationofthetransferaccuracyofabracketjigfabricatedusingcomputeraideddesignandmanufacturingtotheanteriordentitionaninvitrostudy AT nelsongerald threedimensionalevaluationofthetransferaccuracyofabracketjigfabricatedusingcomputeraideddesignandmanufacturingtotheanteriordentitionaninvitrostudy |