Transit time flow measurement predicts graft patency in off-pump coronary artery bypass grafting upon 5-year angiographic follow-up
OBJECTIVE: This retrospective study sought to evaluate the efficacy of transit time flow measurement (TTFM) as a means of predicting bypass graft patency as assessed by coronary artery angiography upon 5-year follow-up. METHODS: Of 311 patients undergone isolated off-pump coronary artery bypass graf...