Cargando…

Comparison of Library of Plans with two daily adaptive strategies for whole bladder radiotherapy

BACKGROUND AND PURPOSE: Whole bladder radiotherapy is challenging due to inter- and intrafraction size and shape changes. To account for these changes, currently a Library of Plans (LoP) technique is often applied, but daily adaptive radiotherapy is also increasingly becoming available. The aim of t...

Descripción completa

Detalles Bibliográficos
Autores principales: den Boer, Duncan, den Hartogh, Mariska D., Kotte, Alexis N.T.J., van der Voort van Zyp, Jochem R.N., Noteboom, Juus L., Bol, Gijsbert H., Willigenburg, Thomas, Werensteijn-Honingh, Anita M., Jürgenliemk-Schulz, Ina M., van Lier, Astrid L.H.M.W., Kroon, Petra S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8609047/
https://www.ncbi.nlm.nih.gov/pubmed/34849413
http://dx.doi.org/10.1016/j.phro.2021.11.002
_version_ 1784602851365879808
author den Boer, Duncan
den Hartogh, Mariska D.
Kotte, Alexis N.T.J.
van der Voort van Zyp, Jochem R.N.
Noteboom, Juus L.
Bol, Gijsbert H.
Willigenburg, Thomas
Werensteijn-Honingh, Anita M.
Jürgenliemk-Schulz, Ina M.
van Lier, Astrid L.H.M.W.
Kroon, Petra S.
author_facet den Boer, Duncan
den Hartogh, Mariska D.
Kotte, Alexis N.T.J.
van der Voort van Zyp, Jochem R.N.
Noteboom, Juus L.
Bol, Gijsbert H.
Willigenburg, Thomas
Werensteijn-Honingh, Anita M.
Jürgenliemk-Schulz, Ina M.
van Lier, Astrid L.H.M.W.
Kroon, Petra S.
author_sort den Boer, Duncan
collection PubMed
description BACKGROUND AND PURPOSE: Whole bladder radiotherapy is challenging due to inter- and intrafraction size and shape changes. To account for these changes, currently a Library of Plans (LoP) technique is often applied, but daily adaptive radiotherapy is also increasingly becoming available. The aim of this study was to compare LoP with two magnetic resonance imaging guided radiotherapy (MRgRT) strategies by comparing target coverage and volume of healthy tissue inside the planning target volume (PTV) for whole bladder treatments. METHODS AND MATERIALS: Data from 25 MRgRT lymph node oligometastases treatments (125 fractions) were used, with three MRI scans acquired at each fraction at 0, 15 and 30 min. Bladders were delineated and used to evaluate three strategies: 1) LoP with two plans for a 15 min fraction, 2) MRgRT(15min) for a 15 min fraction and 3) MRgRT(30min) for a 30 min fraction. The volumes of healthy tissue inside and bladder outside the PTV were analyzed on the simulated post-treatment images. RESULTS: MRgRT(30min) had 120% and 121% more healthy tissue inside the PTV than LoP and MRgRT(15min). For LoP slightly more target outside the PTV was found than for MRgRT(30min) and MRgRT(15min), with median 0% (range 0–23%) compared to 0% (0–20%) and 0% (0–10%), respectively. CONCLUSIONS: Taking into account both target coverage and volume of healthy tissue inside the PTV, MRgRT(15min) performed better than LoP and MRgRT(30min) for whole bladder treatments. A 15 min daily adaptive radiotherapy workflow is needed to potentially benefit from replanning compared to LoP.
format Online
Article
Text
id pubmed-8609047
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-86090472021-11-29 Comparison of Library of Plans with two daily adaptive strategies for whole bladder radiotherapy den Boer, Duncan den Hartogh, Mariska D. Kotte, Alexis N.T.J. van der Voort van Zyp, Jochem R.N. Noteboom, Juus L. Bol, Gijsbert H. Willigenburg, Thomas Werensteijn-Honingh, Anita M. Jürgenliemk-Schulz, Ina M. van Lier, Astrid L.H.M.W. Kroon, Petra S. Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: Whole bladder radiotherapy is challenging due to inter- and intrafraction size and shape changes. To account for these changes, currently a Library of Plans (LoP) technique is often applied, but daily adaptive radiotherapy is also increasingly becoming available. The aim of this study was to compare LoP with two magnetic resonance imaging guided radiotherapy (MRgRT) strategies by comparing target coverage and volume of healthy tissue inside the planning target volume (PTV) for whole bladder treatments. METHODS AND MATERIALS: Data from 25 MRgRT lymph node oligometastases treatments (125 fractions) were used, with three MRI scans acquired at each fraction at 0, 15 and 30 min. Bladders were delineated and used to evaluate three strategies: 1) LoP with two plans for a 15 min fraction, 2) MRgRT(15min) for a 15 min fraction and 3) MRgRT(30min) for a 30 min fraction. The volumes of healthy tissue inside and bladder outside the PTV were analyzed on the simulated post-treatment images. RESULTS: MRgRT(30min) had 120% and 121% more healthy tissue inside the PTV than LoP and MRgRT(15min). For LoP slightly more target outside the PTV was found than for MRgRT(30min) and MRgRT(15min), with median 0% (range 0–23%) compared to 0% (0–20%) and 0% (0–10%), respectively. CONCLUSIONS: Taking into account both target coverage and volume of healthy tissue inside the PTV, MRgRT(15min) performed better than LoP and MRgRT(30min) for whole bladder treatments. A 15 min daily adaptive radiotherapy workflow is needed to potentially benefit from replanning compared to LoP. Elsevier 2021-11-20 /pmc/articles/PMC8609047/ /pubmed/34849413 http://dx.doi.org/10.1016/j.phro.2021.11.002 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research Article
den Boer, Duncan
den Hartogh, Mariska D.
Kotte, Alexis N.T.J.
van der Voort van Zyp, Jochem R.N.
Noteboom, Juus L.
Bol, Gijsbert H.
Willigenburg, Thomas
Werensteijn-Honingh, Anita M.
Jürgenliemk-Schulz, Ina M.
van Lier, Astrid L.H.M.W.
Kroon, Petra S.
Comparison of Library of Plans with two daily adaptive strategies for whole bladder radiotherapy
title Comparison of Library of Plans with two daily adaptive strategies for whole bladder radiotherapy
title_full Comparison of Library of Plans with two daily adaptive strategies for whole bladder radiotherapy
title_fullStr Comparison of Library of Plans with two daily adaptive strategies for whole bladder radiotherapy
title_full_unstemmed Comparison of Library of Plans with two daily adaptive strategies for whole bladder radiotherapy
title_short Comparison of Library of Plans with two daily adaptive strategies for whole bladder radiotherapy
title_sort comparison of library of plans with two daily adaptive strategies for whole bladder radiotherapy
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8609047/
https://www.ncbi.nlm.nih.gov/pubmed/34849413
http://dx.doi.org/10.1016/j.phro.2021.11.002
work_keys_str_mv AT denboerduncan comparisonoflibraryofplanswithtwodailyadaptivestrategiesforwholebladderradiotherapy
AT denhartoghmariskad comparisonoflibraryofplanswithtwodailyadaptivestrategiesforwholebladderradiotherapy
AT kottealexisntj comparisonoflibraryofplanswithtwodailyadaptivestrategiesforwholebladderradiotherapy
AT vandervoortvanzypjochemrn comparisonoflibraryofplanswithtwodailyadaptivestrategiesforwholebladderradiotherapy
AT noteboomjuusl comparisonoflibraryofplanswithtwodailyadaptivestrategiesforwholebladderradiotherapy
AT bolgijsberth comparisonoflibraryofplanswithtwodailyadaptivestrategiesforwholebladderradiotherapy
AT willigenburgthomas comparisonoflibraryofplanswithtwodailyadaptivestrategiesforwholebladderradiotherapy
AT werensteijnhoninghanitam comparisonoflibraryofplanswithtwodailyadaptivestrategiesforwholebladderradiotherapy
AT jurgenliemkschulzinam comparisonoflibraryofplanswithtwodailyadaptivestrategiesforwholebladderradiotherapy
AT vanlierastridlhmw comparisonoflibraryofplanswithtwodailyadaptivestrategiesforwholebladderradiotherapy
AT kroonpetras comparisonoflibraryofplanswithtwodailyadaptivestrategiesforwholebladderradiotherapy