Cargando…

Suture button versus syndesmotic screw in ankle fractures - evaluation with 3D imaging-based measurements

BACKGROUND: Inadequate reduction of syndesmotic injuries can result in disabling clinical outcomes. The aim of the study was to compare syndesmosis congruity after fixation by syndesmotic screws (SYS) or a suture button system (SBS) using three-dimensional (3D) computed imaging techniques. METHODS:...

Descripción completa

Detalles Bibliográficos
Autores principales: Hennings, Robert, Souleiman, Firas, Heilemann, Martin, Hennings, Mareike, Klengel, Alexis, Osterhoff, Georg, Hepp, Pierre, Ahrberg, Annette B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8609744/
https://www.ncbi.nlm.nih.gov/pubmed/34809628
http://dx.doi.org/10.1186/s12891-021-04834-0
Descripción
Sumario:BACKGROUND: Inadequate reduction of syndesmotic injuries can result in disabling clinical outcomes. The aim of the study was to compare syndesmosis congruity after fixation by syndesmotic screws (SYS) or a suture button system (SBS) using three-dimensional (3D) computed imaging techniques. METHODS: In a retrospective single-center study, patients with unilateral stabilization of an ankle fracture with a syndesmotic injury and post-operative bilateral CT scans were analyzed using a recently established 3D method. The side-to-side differences were compared for tibio-fibular clear space (∆CS), translation angle (∆α), and vertical offset (∆z) among patients stabilized with syndesmotic screws or suture button system. Syndesmotic malreduction was defined for ∆CS > 2 mm and for |∆α| > 5°. ∆CS and ∆α were correlated with two-dimensional (2D) measurements. RESULTS: Eighteen patients stabilized with a syndesmosis screw and 29 stabilized with a suture button system were analyzed. After stabilization, both groups revealed mild diastasis (SYS: mean ∆CS 0.3 mm, SD 1.1 mm vs SBS: mean ∆CS 0.2 mm, SD 1.2 mm, p = 0.710). In addition, both stabilization methods showed slight dorsalization of the fibula (SYS: mean ∆α 0.5°, SD 4.6° vs SBS: mean ∆α 2.1°, SD 3.7°, p = 0.192). Also, restoration of the fibula-to-tibia length ratio also did not differ between the two groups (SYS: mean Δz of 0.5 mm, SD 2.4 mm vs SBS: mean Δz of 0 mm, SD 1.2 mm; p = 0.477). Malreduction according to high ∆α was most common (26% of cases), with equal distribution between the groups (p = 0.234). ∆CS and ∆α showed good correlation with 2D measurements (ρ = 0.567; ρ = 0.671). CONCLUSION: This in vivo analysis of post-operative 3D models showed no differences in immediate post-operative alignment after syndesmotic screws or suture button system. Special attention should be paid to syndesmotic malreduction in the sagittal orientation of the fibula in relation to the tibia in radiological control of the syndesmotic congruity as well as intra-operatively.