Cargando…

Addition of castor oil as a booster in colon capsule regimens significantly improves completion rates and polyp detection

BACKGROUND: Incomplete excretion rates are problematic for colon capsule endoscopy (CCE). Widely available booster regimens are suboptimal. Recently published data on one day preparation CCE protocol using castor oil appeared effective. AIM: To assess the impact of adding castor oil to a standard sp...

Descripción completa

Detalles Bibliográficos
Autores principales: Semenov, Serhiy, Ismail, Mohd Syafiq, O'Hara, Fintan, Sihag, Sandeep, Ryan, Barbara, O'Connor, Anthony, O'Donnell, Sarah, McNamara, Deirdre
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8611183/
https://www.ncbi.nlm.nih.gov/pubmed/34877028
http://dx.doi.org/10.4292/wjgpt.v12.i6.103
_version_ 1784603250211684352
author Semenov, Serhiy
Ismail, Mohd Syafiq
O'Hara, Fintan
Sihag, Sandeep
Ryan, Barbara
O'Connor, Anthony
O'Donnell, Sarah
McNamara, Deirdre
author_facet Semenov, Serhiy
Ismail, Mohd Syafiq
O'Hara, Fintan
Sihag, Sandeep
Ryan, Barbara
O'Connor, Anthony
O'Donnell, Sarah
McNamara, Deirdre
author_sort Semenov, Serhiy
collection PubMed
description BACKGROUND: Incomplete excretion rates are problematic for colon capsule endoscopy (CCE). Widely available booster regimens are suboptimal. Recently published data on one day preparation CCE protocol using castor oil appeared effective. AIM: To assess the impact of adding castor oil to a standard split-dose (2-d) preparation in an unselected Western patient cohort. METHODS: All patients aged 18 or more referred to our unit for a CCE over a 5-mo period were prospectively recruited. Controls were retrospectively identified from our CCE database. All patients received split bowel preparation with Moviprep(® )[polyethylene glycol (PEG)-3350, sodium sulphate, sodium chloride, potassium chloride, sodium ascorbate and ascorbic acid for oral solution; Norgine B. V, United States], a PEG-based solution used predominantly in our colonoscopy practice. Control booster regimen included Moviprep(® )with 750 mL of water (booster 1) on reaching the small bowel. A further dose of Moviprep(® )with 250 mL of water was given 3 h later and a bisacodyl suppository (Dulcolax(®)) 10 mg after 8 h, if the capsule was not excreted. In addition to our standard booster regimen, cases received an additional 15 mL of castor oil given at the time of booster 1. A nested case control design with 2:1 ratio (control:case) was employed. Basic demographics, completion rates, image quality, colonic transit time, diagnostic yield and polyp detection were compared between groups, using a student t or chi-square tests as appropriate. RESULTS: One hundred and eighty-six CCEs [mean age 60 years (18-97), 56% females, n = 104], including 62 cases have been analysed. Indication breakdown included 96 polyp surveillance (51.6%), 42 lower gastrointestinal symptoms (22.6%), 28 due to incomplete colonoscopy (15%), 18 anaemia (9.7%) and 2 inflammatory bowel disease surveillance (1.1%). Overall, CCE completion was 77% (144/186), image quality was adequate/diagnostic in 91% (170/186), mean colonic transit time was 3.5 h (0.25-13), and the polyp detection rate was 57% (106/186). Completion rates were significantly higher with castor oil, 87% cases (54/62) vs 73% controls (90/124), P = 0.01. The number needed to treat with castor oil to result in an additional complete CCE study was 7, absolute risk reduction = 14.52%, 95% confidence interval (CI): 3.06- 25.97. This effect of castor oil on excretion rates was more significant in the over 60 s, P < 0.03, and in females, P < 0.025. Similarly, polyp detection rates were higher in cases 82% (51/62) vs controls 44% (55/124), P = 0.0001, odds ratio 5.8, 95%CI: 2.77-12.21. Colonic transit times were similar, 3.2 h and 3.8 h, respectively. Image quality was similar, reported as adequate/diagnostic in 90% (56/62) vs 92% (114/124). CONCLUSION: In our capsule endoscopy centre, castor oil addition as a CCE booster significantly improved completion rates and polyp detection in an unselected Western cohort.
format Online
Article
Text
id pubmed-8611183
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-86111832021-12-06 Addition of castor oil as a booster in colon capsule regimens significantly improves completion rates and polyp detection Semenov, Serhiy Ismail, Mohd Syafiq O'Hara, Fintan Sihag, Sandeep Ryan, Barbara O'Connor, Anthony O'Donnell, Sarah McNamara, Deirdre World J Gastrointest Pharmacol Ther Prospective Study BACKGROUND: Incomplete excretion rates are problematic for colon capsule endoscopy (CCE). Widely available booster regimens are suboptimal. Recently published data on one day preparation CCE protocol using castor oil appeared effective. AIM: To assess the impact of adding castor oil to a standard split-dose (2-d) preparation in an unselected Western patient cohort. METHODS: All patients aged 18 or more referred to our unit for a CCE over a 5-mo period were prospectively recruited. Controls were retrospectively identified from our CCE database. All patients received split bowel preparation with Moviprep(® )[polyethylene glycol (PEG)-3350, sodium sulphate, sodium chloride, potassium chloride, sodium ascorbate and ascorbic acid for oral solution; Norgine B. V, United States], a PEG-based solution used predominantly in our colonoscopy practice. Control booster regimen included Moviprep(® )with 750 mL of water (booster 1) on reaching the small bowel. A further dose of Moviprep(® )with 250 mL of water was given 3 h later and a bisacodyl suppository (Dulcolax(®)) 10 mg after 8 h, if the capsule was not excreted. In addition to our standard booster regimen, cases received an additional 15 mL of castor oil given at the time of booster 1. A nested case control design with 2:1 ratio (control:case) was employed. Basic demographics, completion rates, image quality, colonic transit time, diagnostic yield and polyp detection were compared between groups, using a student t or chi-square tests as appropriate. RESULTS: One hundred and eighty-six CCEs [mean age 60 years (18-97), 56% females, n = 104], including 62 cases have been analysed. Indication breakdown included 96 polyp surveillance (51.6%), 42 lower gastrointestinal symptoms (22.6%), 28 due to incomplete colonoscopy (15%), 18 anaemia (9.7%) and 2 inflammatory bowel disease surveillance (1.1%). Overall, CCE completion was 77% (144/186), image quality was adequate/diagnostic in 91% (170/186), mean colonic transit time was 3.5 h (0.25-13), and the polyp detection rate was 57% (106/186). Completion rates were significantly higher with castor oil, 87% cases (54/62) vs 73% controls (90/124), P = 0.01. The number needed to treat with castor oil to result in an additional complete CCE study was 7, absolute risk reduction = 14.52%, 95% confidence interval (CI): 3.06- 25.97. This effect of castor oil on excretion rates was more significant in the over 60 s, P < 0.03, and in females, P < 0.025. Similarly, polyp detection rates were higher in cases 82% (51/62) vs controls 44% (55/124), P = 0.0001, odds ratio 5.8, 95%CI: 2.77-12.21. Colonic transit times were similar, 3.2 h and 3.8 h, respectively. Image quality was similar, reported as adequate/diagnostic in 90% (56/62) vs 92% (114/124). CONCLUSION: In our capsule endoscopy centre, castor oil addition as a CCE booster significantly improved completion rates and polyp detection in an unselected Western cohort. Baishideng Publishing Group Inc 2021-11-05 2021-11-05 /pmc/articles/PMC8611183/ /pubmed/34877028 http://dx.doi.org/10.4292/wjgpt.v12.i6.103 Text en ©The Author(s) 2021. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial.
spellingShingle Prospective Study
Semenov, Serhiy
Ismail, Mohd Syafiq
O'Hara, Fintan
Sihag, Sandeep
Ryan, Barbara
O'Connor, Anthony
O'Donnell, Sarah
McNamara, Deirdre
Addition of castor oil as a booster in colon capsule regimens significantly improves completion rates and polyp detection
title Addition of castor oil as a booster in colon capsule regimens significantly improves completion rates and polyp detection
title_full Addition of castor oil as a booster in colon capsule regimens significantly improves completion rates and polyp detection
title_fullStr Addition of castor oil as a booster in colon capsule regimens significantly improves completion rates and polyp detection
title_full_unstemmed Addition of castor oil as a booster in colon capsule regimens significantly improves completion rates and polyp detection
title_short Addition of castor oil as a booster in colon capsule regimens significantly improves completion rates and polyp detection
title_sort addition of castor oil as a booster in colon capsule regimens significantly improves completion rates and polyp detection
topic Prospective Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8611183/
https://www.ncbi.nlm.nih.gov/pubmed/34877028
http://dx.doi.org/10.4292/wjgpt.v12.i6.103
work_keys_str_mv AT semenovserhiy additionofcastoroilasaboosterincoloncapsuleregimenssignificantlyimprovescompletionratesandpolypdetection
AT ismailmohdsyafiq additionofcastoroilasaboosterincoloncapsuleregimenssignificantlyimprovescompletionratesandpolypdetection
AT oharafintan additionofcastoroilasaboosterincoloncapsuleregimenssignificantlyimprovescompletionratesandpolypdetection
AT sihagsandeep additionofcastoroilasaboosterincoloncapsuleregimenssignificantlyimprovescompletionratesandpolypdetection
AT ryanbarbara additionofcastoroilasaboosterincoloncapsuleregimenssignificantlyimprovescompletionratesandpolypdetection
AT oconnoranthony additionofcastoroilasaboosterincoloncapsuleregimenssignificantlyimprovescompletionratesandpolypdetection
AT odonnellsarah additionofcastoroilasaboosterincoloncapsuleregimenssignificantlyimprovescompletionratesandpolypdetection
AT mcnamaradeirdre additionofcastoroilasaboosterincoloncapsuleregimenssignificantlyimprovescompletionratesandpolypdetection