Cargando…
Immunogenicity trends 1 and 3 months after second BNT162B2 vaccination among healthcare workers in Israel
OBJECTIVES: We evaluated the antibody response to the BNT162B2 vaccine among healthcare workers (HCWs) to identify factors associated with decreased immunogenicity. METHODS: This prospective cohort study included consenting HCWs who completed a questionnaire regarding background illnesses, medicatio...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8611821/ https://www.ncbi.nlm.nih.gov/pubmed/34838782 http://dx.doi.org/10.1016/j.cmi.2021.11.014 |
Sumario: | OBJECTIVES: We evaluated the antibody response to the BNT162B2 vaccine among healthcare workers (HCWs) to identify factors associated with decreased immunogenicity. METHODS: This prospective cohort study included consenting HCWs who completed a questionnaire regarding background illnesses, medications, and post-vaccination allergic reactions or rash. All HCWs were tested for anti-spike antibodies (LIAISON SARS-CoV-2 S1/S2 IgG assay) 1 and 3 months after the second vaccine dose. A multivariate mixed linear model was adjusted to participants' data and fit to predict antibody levels after the second BNT162B2 vaccine dose, based on antibody levels at 1 month and the slope between 3 months and 1 month. Multivariate analyses identified factors associated with lower antibody levels. RESULTS: In total 1506 HCWs were tested for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies. Older age was associated with lower mean antibody levels (–1.22 AU/mL, p < 0.001, 95%CI –1.43 to –1.01). In addition, male sex (–22.16 AU/mL, p < 0.001, 95%CI –27.93 to –16.39), underlying condition (–10.86 AU/mL, p 0.007, 95%CI –18.81 to –2.91) and immunosuppressive treatment (–28.57 AU/mL, p 0.002, 95%CI –46.85 to –10.29) were associated with significantly lower mean antibody levels. Allergic reactions after vaccine administration or peri-vaccination glucocorticosteroid treatment were not correlated with antibody levels. CONCLUSIONS: Most HCWs had measurable antibodies at 3 months. Risk factors for lower antibody levels were older age, male sex, underlying condition, and immunosuppressive treatment. These factors may be considered when planning booster doses during vaccine shortages. |
---|