Management of a Complex Supracondylar Periprosthetic Femur Fracture with Intramedullary Strut Allograft and Bilateral Locking Plates

Supracondylar periprosthetic femoral fractures occurring above total knee replacements have been considered a rare entity. However, they continue to increase in frequency with the increasing number of arthroplasties and the improvement in morbidity and mortality in the concerned patient population....

Descripción completa

Detalles Bibliográficos
Autores principales: Moukarzel, Rita, Aouad, Dany, Daher, Mohammad, Ghanem, Wendy, Ezzeddine, Hady, El Rassi, George
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8612792/
https://www.ncbi.nlm.nih.gov/pubmed/34840840
http://dx.doi.org/10.1155/2021/4882382
_version_ 1784603517929914368
author Moukarzel, Rita
Aouad, Dany
Daher, Mohammad
Ghanem, Wendy
Ezzeddine, Hady
El Rassi, George
author_facet Moukarzel, Rita
Aouad, Dany
Daher, Mohammad
Ghanem, Wendy
Ezzeddine, Hady
El Rassi, George
author_sort Moukarzel, Rita
collection PubMed
description Supracondylar periprosthetic femoral fractures occurring above total knee replacements have been considered a rare entity. However, they continue to increase in frequency with the increasing number of arthroplasties and the improvement in morbidity and mortality in the concerned patient population. The management of periprosthetic distal femoral fractures is a challenging orthopedic problem. In this brief communication, a case of 49-year-old woman with rheumatoid arthritis who sustained a low distal comminuted periprosthetic femoral fracture is presented. Her fracture was eventually managed with an intramedullary fibular strut allograft and bilateral locking plate placement reaching satisfactory healing and restoration of alignment. The primary aim of this report is to provide insight into this novel technique as a successful alternative to other standard surgical options.
format Online
Article
Text
id pubmed-8612792
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-86127922021-11-25 Management of a Complex Supracondylar Periprosthetic Femur Fracture with Intramedullary Strut Allograft and Bilateral Locking Plates Moukarzel, Rita Aouad, Dany Daher, Mohammad Ghanem, Wendy Ezzeddine, Hady El Rassi, George Case Rep Orthop Case Report Supracondylar periprosthetic femoral fractures occurring above total knee replacements have been considered a rare entity. However, they continue to increase in frequency with the increasing number of arthroplasties and the improvement in morbidity and mortality in the concerned patient population. The management of periprosthetic distal femoral fractures is a challenging orthopedic problem. In this brief communication, a case of 49-year-old woman with rheumatoid arthritis who sustained a low distal comminuted periprosthetic femoral fracture is presented. Her fracture was eventually managed with an intramedullary fibular strut allograft and bilateral locking plate placement reaching satisfactory healing and restoration of alignment. The primary aim of this report is to provide insight into this novel technique as a successful alternative to other standard surgical options. Hindawi 2021-11-17 /pmc/articles/PMC8612792/ /pubmed/34840840 http://dx.doi.org/10.1155/2021/4882382 Text en Copyright © 2021 Rita Moukarzel et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Moukarzel, Rita
Aouad, Dany
Daher, Mohammad
Ghanem, Wendy
Ezzeddine, Hady
El Rassi, George
Management of a Complex Supracondylar Periprosthetic Femur Fracture with Intramedullary Strut Allograft and Bilateral Locking Plates
title Management of a Complex Supracondylar Periprosthetic Femur Fracture with Intramedullary Strut Allograft and Bilateral Locking Plates
title_full Management of a Complex Supracondylar Periprosthetic Femur Fracture with Intramedullary Strut Allograft and Bilateral Locking Plates
title_fullStr Management of a Complex Supracondylar Periprosthetic Femur Fracture with Intramedullary Strut Allograft and Bilateral Locking Plates
title_full_unstemmed Management of a Complex Supracondylar Periprosthetic Femur Fracture with Intramedullary Strut Allograft and Bilateral Locking Plates
title_short Management of a Complex Supracondylar Periprosthetic Femur Fracture with Intramedullary Strut Allograft and Bilateral Locking Plates
title_sort management of a complex supracondylar periprosthetic femur fracture with intramedullary strut allograft and bilateral locking plates
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8612792/
https://www.ncbi.nlm.nih.gov/pubmed/34840840
http://dx.doi.org/10.1155/2021/4882382
work_keys_str_mv AT moukarzelrita managementofacomplexsupracondylarperiprostheticfemurfracturewithintramedullarystrutallograftandbilaterallockingplates
AT aouaddany managementofacomplexsupracondylarperiprostheticfemurfracturewithintramedullarystrutallograftandbilaterallockingplates
AT dahermohammad managementofacomplexsupracondylarperiprostheticfemurfracturewithintramedullarystrutallograftandbilaterallockingplates
AT ghanemwendy managementofacomplexsupracondylarperiprostheticfemurfracturewithintramedullarystrutallograftandbilaterallockingplates
AT ezzeddinehady managementofacomplexsupracondylarperiprostheticfemurfracturewithintramedullarystrutallograftandbilaterallockingplates
AT elrassigeorge managementofacomplexsupracondylarperiprostheticfemurfracturewithintramedullarystrutallograftandbilaterallockingplates