Cargando…

Evaluating sensitivity and specificity of the Biomeme Franklin™ three9 real-time PCR device and SARS-CoV-2 go-strips assay using clinical samples

We evaluated the sensitivity and specificity of the Biomeme Franklin™ three9 Real-Time PCR Thermocycler and Biomeme SARS-CoV-2 Go-Strips in the detection of SARS-CoV-2. The Biomeme Franklin™ three9 platform is a portable, battery-operated system that could be used in remote settings. We assessed per...

Descripción completa

Detalles Bibliográficos
Autores principales: Voelker, Chet R., Ochoa, Anna R., Armstrong-Spenrath, La'Quita, Lott, Lisa, McDaniel, Jennifer S., Blackburn, August N., Cornell, Lauren E., Mahoney, Rachel, Asin, Susana N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8613008/
https://www.ncbi.nlm.nih.gov/pubmed/34863057
http://dx.doi.org/10.1016/j.jcv.2021.105046
_version_ 1784603546308575232
author Voelker, Chet R.
Ochoa, Anna R.
Armstrong-Spenrath, La'Quita
Lott, Lisa
McDaniel, Jennifer S.
Blackburn, August N.
Cornell, Lauren E.
Mahoney, Rachel
Asin, Susana N.
author_facet Voelker, Chet R.
Ochoa, Anna R.
Armstrong-Spenrath, La'Quita
Lott, Lisa
McDaniel, Jennifer S.
Blackburn, August N.
Cornell, Lauren E.
Mahoney, Rachel
Asin, Susana N.
author_sort Voelker, Chet R.
collection PubMed
description We evaluated the sensitivity and specificity of the Biomeme Franklin™ three9 Real-Time PCR Thermocycler and Biomeme SARS-CoV-2 Go-Strips in the detection of SARS-CoV-2. The Biomeme Franklin™ three9 platform is a portable, battery-operated system that could be used in remote settings. We assessed performance of the Biomeme SARS-CoV-2 detection system at a wide range of viral concentrations, examined cross-reactivity of the SARS-CoV-2 Go-Strips against several near-neighbor respiratory pathogens, and evaluated agreement against the BioFire® Respiratory Panel 2.1 in four clinical sample types. Our data indicate the Biomeme Go-Strips can reliably detect SARS-CoV-2 at a concentration of 4.2 × 10(3) copies/mL. No cross reactivity of the Go-Strips targets was detected against any of the tested near-neighbor respiratory pathogens. Cohen's kappa statistics ranged from 0.68 to 0.92 between results from the Biomeme SARS-CoV-2 Go-Strips and the BioFire® Respiratory Panel 2.1 in all the different sample types. Compared to the BioFire® Respiratory Panel 2.1, the Biomeme SARS-CoV-2 Go-Strips demonstrated statistically significantly lower sensitivity in 3 out of 5 sample types. Overall, our study demonstrates the Biomeme Franklin™ three9 used with the SARS-CoV-2 Go-Strips is an effective system for the detection of SARS-CoV-2 that could potentially be used in a remote or austere environment.
format Online
Article
Text
id pubmed-8613008
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier Science
record_format MEDLINE/PubMed
spelling pubmed-86130082021-11-26 Evaluating sensitivity and specificity of the Biomeme Franklin™ three9 real-time PCR device and SARS-CoV-2 go-strips assay using clinical samples Voelker, Chet R. Ochoa, Anna R. Armstrong-Spenrath, La'Quita Lott, Lisa McDaniel, Jennifer S. Blackburn, August N. Cornell, Lauren E. Mahoney, Rachel Asin, Susana N. J Clin Virol Article We evaluated the sensitivity and specificity of the Biomeme Franklin™ three9 Real-Time PCR Thermocycler and Biomeme SARS-CoV-2 Go-Strips in the detection of SARS-CoV-2. The Biomeme Franklin™ three9 platform is a portable, battery-operated system that could be used in remote settings. We assessed performance of the Biomeme SARS-CoV-2 detection system at a wide range of viral concentrations, examined cross-reactivity of the SARS-CoV-2 Go-Strips against several near-neighbor respiratory pathogens, and evaluated agreement against the BioFire® Respiratory Panel 2.1 in four clinical sample types. Our data indicate the Biomeme Go-Strips can reliably detect SARS-CoV-2 at a concentration of 4.2 × 10(3) copies/mL. No cross reactivity of the Go-Strips targets was detected against any of the tested near-neighbor respiratory pathogens. Cohen's kappa statistics ranged from 0.68 to 0.92 between results from the Biomeme SARS-CoV-2 Go-Strips and the BioFire® Respiratory Panel 2.1 in all the different sample types. Compared to the BioFire® Respiratory Panel 2.1, the Biomeme SARS-CoV-2 Go-Strips demonstrated statistically significantly lower sensitivity in 3 out of 5 sample types. Overall, our study demonstrates the Biomeme Franklin™ three9 used with the SARS-CoV-2 Go-Strips is an effective system for the detection of SARS-CoV-2 that could potentially be used in a remote or austere environment. Elsevier Science 2022-01 2021-11-25 /pmc/articles/PMC8613008/ /pubmed/34863057 http://dx.doi.org/10.1016/j.jcv.2021.105046 Text en Published by Elsevier B.V. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Voelker, Chet R.
Ochoa, Anna R.
Armstrong-Spenrath, La'Quita
Lott, Lisa
McDaniel, Jennifer S.
Blackburn, August N.
Cornell, Lauren E.
Mahoney, Rachel
Asin, Susana N.
Evaluating sensitivity and specificity of the Biomeme Franklin™ three9 real-time PCR device and SARS-CoV-2 go-strips assay using clinical samples
title Evaluating sensitivity and specificity of the Biomeme Franklin™ three9 real-time PCR device and SARS-CoV-2 go-strips assay using clinical samples
title_full Evaluating sensitivity and specificity of the Biomeme Franklin™ three9 real-time PCR device and SARS-CoV-2 go-strips assay using clinical samples
title_fullStr Evaluating sensitivity and specificity of the Biomeme Franklin™ three9 real-time PCR device and SARS-CoV-2 go-strips assay using clinical samples
title_full_unstemmed Evaluating sensitivity and specificity of the Biomeme Franklin™ three9 real-time PCR device and SARS-CoV-2 go-strips assay using clinical samples
title_short Evaluating sensitivity and specificity of the Biomeme Franklin™ three9 real-time PCR device and SARS-CoV-2 go-strips assay using clinical samples
title_sort evaluating sensitivity and specificity of the biomeme franklin™ three9 real-time pcr device and sars-cov-2 go-strips assay using clinical samples
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8613008/
https://www.ncbi.nlm.nih.gov/pubmed/34863057
http://dx.doi.org/10.1016/j.jcv.2021.105046
work_keys_str_mv AT voelkerchetr evaluatingsensitivityandspecificityofthebiomemefranklinthree9realtimepcrdeviceandsarscov2gostripsassayusingclinicalsamples
AT ochoaannar evaluatingsensitivityandspecificityofthebiomemefranklinthree9realtimepcrdeviceandsarscov2gostripsassayusingclinicalsamples
AT armstrongspenrathlaquita evaluatingsensitivityandspecificityofthebiomemefranklinthree9realtimepcrdeviceandsarscov2gostripsassayusingclinicalsamples
AT lottlisa evaluatingsensitivityandspecificityofthebiomemefranklinthree9realtimepcrdeviceandsarscov2gostripsassayusingclinicalsamples
AT mcdanieljennifers evaluatingsensitivityandspecificityofthebiomemefranklinthree9realtimepcrdeviceandsarscov2gostripsassayusingclinicalsamples
AT blackburnaugustn evaluatingsensitivityandspecificityofthebiomemefranklinthree9realtimepcrdeviceandsarscov2gostripsassayusingclinicalsamples
AT cornelllaurene evaluatingsensitivityandspecificityofthebiomemefranklinthree9realtimepcrdeviceandsarscov2gostripsassayusingclinicalsamples
AT mahoneyrachel evaluatingsensitivityandspecificityofthebiomemefranklinthree9realtimepcrdeviceandsarscov2gostripsassayusingclinicalsamples
AT asinsusanan evaluatingsensitivityandspecificityofthebiomemefranklinthree9realtimepcrdeviceandsarscov2gostripsassayusingclinicalsamples