Total Fluoroscopy Time Reduction During Ultrasound- and Fluoroscopy-Guided Percutaneous Transhepatic Biliary Drainage Procedure: Importance of Adjusting the Puncture Angle
BACKGROUND: The purpose of this observational cohort study was to assess patient and operator-dependent factors which could have an impact on total fluoroscopy time during ultrasound and fluoroscopy-guided percutaneous transhepatic biliary drainage (PTBD). MATERIAL/METHODS: Between October 2016 and...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8614062/ https://www.ncbi.nlm.nih.gov/pubmed/34802031 http://dx.doi.org/10.12659/MSM.933889 |
_version_ | 1784603778464350208 |
---|---|
author | Filipović, Aleksandar N. Mašulović, Dragan Zakošek, Miloš Filipović, Tamara Galun, Danijel |
author_facet | Filipović, Aleksandar N. Mašulović, Dragan Zakošek, Miloš Filipović, Tamara Galun, Danijel |
author_sort | Filipović, Aleksandar N. |
collection | PubMed |
description | BACKGROUND: The purpose of this observational cohort study was to assess patient and operator-dependent factors which could have an impact on total fluoroscopy time during ultrasound and fluoroscopy-guided percutaneous transhepatic biliary drainage (PTBD). MATERIAL/METHODS: Between October 2016 and November 2020, 127 patients with malignant biliary obstruction underwent ultrasound- and fluoroscopy-guided PTBD with the right-sided intercostal approach. The initial bile duct puncture was ultrasound-guided in all patients, and the puncture angle was measured by ultrasound. Any subsequent steps of the procedure were performed under continuous fluoroscopy (15 fps). The patients were divided in 2 groups based on the puncture angle: ≤30° (group I) and >30° (group II). In a retrospective analysis, both groups were compared for inter- and intragroup variability, technical success, total fluoroscopy time, and complications. RESULTS: In group II, the recorded total fluoroscopy time (232.20±140.94 s) was significantly longer than that in group I (83.44±52.61 s) (P<0.001). In both groups, total fluoroscopy time was significantly longer in cases with a lesser degree of bile duct dilatation, intrahepatic bile duct tortuosity, presence of liver metastases, and multiple intrahepatic bile duct strictures. CONCLUSIONS: The initial bile duct puncture angle was identified as an operator-dependent factor with the possible impact on total fluoroscopy time. The puncture angle of less than 30° was positively correlated with overall procedure efficacy and total fluoroscopy time reduction. |
format | Online Article Text |
id | pubmed-8614062 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-86140622021-12-13 Total Fluoroscopy Time Reduction During Ultrasound- and Fluoroscopy-Guided Percutaneous Transhepatic Biliary Drainage Procedure: Importance of Adjusting the Puncture Angle Filipović, Aleksandar N. Mašulović, Dragan Zakošek, Miloš Filipović, Tamara Galun, Danijel Med Sci Monit Clinical Research BACKGROUND: The purpose of this observational cohort study was to assess patient and operator-dependent factors which could have an impact on total fluoroscopy time during ultrasound and fluoroscopy-guided percutaneous transhepatic biliary drainage (PTBD). MATERIAL/METHODS: Between October 2016 and November 2020, 127 patients with malignant biliary obstruction underwent ultrasound- and fluoroscopy-guided PTBD with the right-sided intercostal approach. The initial bile duct puncture was ultrasound-guided in all patients, and the puncture angle was measured by ultrasound. Any subsequent steps of the procedure were performed under continuous fluoroscopy (15 fps). The patients were divided in 2 groups based on the puncture angle: ≤30° (group I) and >30° (group II). In a retrospective analysis, both groups were compared for inter- and intragroup variability, technical success, total fluoroscopy time, and complications. RESULTS: In group II, the recorded total fluoroscopy time (232.20±140.94 s) was significantly longer than that in group I (83.44±52.61 s) (P<0.001). In both groups, total fluoroscopy time was significantly longer in cases with a lesser degree of bile duct dilatation, intrahepatic bile duct tortuosity, presence of liver metastases, and multiple intrahepatic bile duct strictures. CONCLUSIONS: The initial bile duct puncture angle was identified as an operator-dependent factor with the possible impact on total fluoroscopy time. The puncture angle of less than 30° was positively correlated with overall procedure efficacy and total fluoroscopy time reduction. International Scientific Literature, Inc. 2021-11-21 /pmc/articles/PMC8614062/ /pubmed/34802031 http://dx.doi.org/10.12659/MSM.933889 Text en © Med Sci Monit, 2021 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) |
spellingShingle | Clinical Research Filipović, Aleksandar N. Mašulović, Dragan Zakošek, Miloš Filipović, Tamara Galun, Danijel Total Fluoroscopy Time Reduction During Ultrasound- and Fluoroscopy-Guided Percutaneous Transhepatic Biliary Drainage Procedure: Importance of Adjusting the Puncture Angle |
title | Total Fluoroscopy Time Reduction During Ultrasound- and Fluoroscopy-Guided Percutaneous Transhepatic Biliary Drainage Procedure: Importance of Adjusting the Puncture Angle |
title_full | Total Fluoroscopy Time Reduction During Ultrasound- and Fluoroscopy-Guided Percutaneous Transhepatic Biliary Drainage Procedure: Importance of Adjusting the Puncture Angle |
title_fullStr | Total Fluoroscopy Time Reduction During Ultrasound- and Fluoroscopy-Guided Percutaneous Transhepatic Biliary Drainage Procedure: Importance of Adjusting the Puncture Angle |
title_full_unstemmed | Total Fluoroscopy Time Reduction During Ultrasound- and Fluoroscopy-Guided Percutaneous Transhepatic Biliary Drainage Procedure: Importance of Adjusting the Puncture Angle |
title_short | Total Fluoroscopy Time Reduction During Ultrasound- and Fluoroscopy-Guided Percutaneous Transhepatic Biliary Drainage Procedure: Importance of Adjusting the Puncture Angle |
title_sort | total fluoroscopy time reduction during ultrasound- and fluoroscopy-guided percutaneous transhepatic biliary drainage procedure: importance of adjusting the puncture angle |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8614062/ https://www.ncbi.nlm.nih.gov/pubmed/34802031 http://dx.doi.org/10.12659/MSM.933889 |
work_keys_str_mv | AT filipovicaleksandarn totalfluoroscopytimereductionduringultrasoundandfluoroscopyguidedpercutaneoustranshepaticbiliarydrainageprocedureimportanceofadjustingthepunctureangle AT masulovicdragan totalfluoroscopytimereductionduringultrasoundandfluoroscopyguidedpercutaneoustranshepaticbiliarydrainageprocedureimportanceofadjustingthepunctureangle AT zakosekmilos totalfluoroscopytimereductionduringultrasoundandfluoroscopyguidedpercutaneoustranshepaticbiliarydrainageprocedureimportanceofadjustingthepunctureangle AT filipovictamara totalfluoroscopytimereductionduringultrasoundandfluoroscopyguidedpercutaneoustranshepaticbiliarydrainageprocedureimportanceofadjustingthepunctureangle AT galundanijel totalfluoroscopytimereductionduringultrasoundandfluoroscopyguidedpercutaneoustranshepaticbiliarydrainageprocedureimportanceofadjustingthepunctureangle |