Cargando…

Comparison of Conventional and Radiomic Features between (18)F-FBPA PET/CT and PET/MR

Boron-10-containing positron emission tomography (PET) radio-tracer, (18)F-FBPA, has been used to evaluate the feasibility and treatment outcomes of Boron neutron capture therapy (BNCT). The clinical use of PET/MR is increasing and reveals its benefit in certain applications. However, the PET/CT is...

Descripción completa

Detalles Bibliográficos
Autores principales: Liao, Chien-Yi, Jen, Jun-Hsuang, Chen, Yi-Wei, Li, Chien-Ying, Wang, Ling-Wei, Liu, Ren-Shyan, Huang, Wen-Sheng, Lu, Chia-Feng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8615400/
https://www.ncbi.nlm.nih.gov/pubmed/34827657
http://dx.doi.org/10.3390/biom11111659
_version_ 1784604095428952064
author Liao, Chien-Yi
Jen, Jun-Hsuang
Chen, Yi-Wei
Li, Chien-Ying
Wang, Ling-Wei
Liu, Ren-Shyan
Huang, Wen-Sheng
Lu, Chia-Feng
author_facet Liao, Chien-Yi
Jen, Jun-Hsuang
Chen, Yi-Wei
Li, Chien-Ying
Wang, Ling-Wei
Liu, Ren-Shyan
Huang, Wen-Sheng
Lu, Chia-Feng
author_sort Liao, Chien-Yi
collection PubMed
description Boron-10-containing positron emission tomography (PET) radio-tracer, (18)F-FBPA, has been used to evaluate the feasibility and treatment outcomes of Boron neutron capture therapy (BNCT). The clinical use of PET/MR is increasing and reveals its benefit in certain applications. However, the PET/CT is still the most widely used modality for daily PET practice due to its high quantitative accuracy and relatively low cost. Considering the different attenuation correction maps between PET/CT and PET/MR, comparison of derived image features from these two modalities is critical to identify quantitative imaging biomarkers for diagnosis and prognosis. This study aimed to investigate the comparability of image features extracted from (18)F-FBPA PET/CT and PET/MR. A total of 15 patients with malignant brain tumor who underwent (18)F-FBPA examinations using both PET/CT and PET/MR on the same day were retrospectively analyzed. Overall, four conventional imaging characteristics and 449 radiomic features were calculated from PET/CT and PET/MR, respectively. A linear regression model and intraclass correlation coefficient (ICC) were estimated to evaluate the comparability of derived features between two modalities. Features were classified into strong, moderate, and weak comparability based on coefficient of determination (r(2)) and ICC. All of the conventional features, 81.2% of histogram, 37.5% of geometry, 51.5% of texture, and 25% of wavelet-based features, showed strong comparability between PET/CT and PET/MR. With regard to the wavelet filtering, radiomic features without filtering (61.2%) or with low-pass filtering (59.2%) along three axes produced strong comparability between the two modalities. However, only 8.2% of the features with high-pass filtering showed strong comparability. The linear regression models were provided for the features with strong and moderate consensus to interchange the quantitative features between the PET/CT and the PET/MR. All of the conventional and 71% of the radiomic (mostly histogram and texture) features were sufficiently stable and could be interchanged between (18)F-FBPA PET with different hybrid modalities using the proposed equations. Our findings suggested that the image features high interchangeability may facilitate future studies in comparing PET/CT and PET/MR.
format Online
Article
Text
id pubmed-8615400
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86154002021-11-26 Comparison of Conventional and Radiomic Features between (18)F-FBPA PET/CT and PET/MR Liao, Chien-Yi Jen, Jun-Hsuang Chen, Yi-Wei Li, Chien-Ying Wang, Ling-Wei Liu, Ren-Shyan Huang, Wen-Sheng Lu, Chia-Feng Biomolecules Article Boron-10-containing positron emission tomography (PET) radio-tracer, (18)F-FBPA, has been used to evaluate the feasibility and treatment outcomes of Boron neutron capture therapy (BNCT). The clinical use of PET/MR is increasing and reveals its benefit in certain applications. However, the PET/CT is still the most widely used modality for daily PET practice due to its high quantitative accuracy and relatively low cost. Considering the different attenuation correction maps between PET/CT and PET/MR, comparison of derived image features from these two modalities is critical to identify quantitative imaging biomarkers for diagnosis and prognosis. This study aimed to investigate the comparability of image features extracted from (18)F-FBPA PET/CT and PET/MR. A total of 15 patients with malignant brain tumor who underwent (18)F-FBPA examinations using both PET/CT and PET/MR on the same day were retrospectively analyzed. Overall, four conventional imaging characteristics and 449 radiomic features were calculated from PET/CT and PET/MR, respectively. A linear regression model and intraclass correlation coefficient (ICC) were estimated to evaluate the comparability of derived features between two modalities. Features were classified into strong, moderate, and weak comparability based on coefficient of determination (r(2)) and ICC. All of the conventional features, 81.2% of histogram, 37.5% of geometry, 51.5% of texture, and 25% of wavelet-based features, showed strong comparability between PET/CT and PET/MR. With regard to the wavelet filtering, radiomic features without filtering (61.2%) or with low-pass filtering (59.2%) along three axes produced strong comparability between the two modalities. However, only 8.2% of the features with high-pass filtering showed strong comparability. The linear regression models were provided for the features with strong and moderate consensus to interchange the quantitative features between the PET/CT and the PET/MR. All of the conventional and 71% of the radiomic (mostly histogram and texture) features were sufficiently stable and could be interchanged between (18)F-FBPA PET with different hybrid modalities using the proposed equations. Our findings suggested that the image features high interchangeability may facilitate future studies in comparing PET/CT and PET/MR. MDPI 2021-11-09 /pmc/articles/PMC8615400/ /pubmed/34827657 http://dx.doi.org/10.3390/biom11111659 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liao, Chien-Yi
Jen, Jun-Hsuang
Chen, Yi-Wei
Li, Chien-Ying
Wang, Ling-Wei
Liu, Ren-Shyan
Huang, Wen-Sheng
Lu, Chia-Feng
Comparison of Conventional and Radiomic Features between (18)F-FBPA PET/CT and PET/MR
title Comparison of Conventional and Radiomic Features between (18)F-FBPA PET/CT and PET/MR
title_full Comparison of Conventional and Radiomic Features between (18)F-FBPA PET/CT and PET/MR
title_fullStr Comparison of Conventional and Radiomic Features between (18)F-FBPA PET/CT and PET/MR
title_full_unstemmed Comparison of Conventional and Radiomic Features between (18)F-FBPA PET/CT and PET/MR
title_short Comparison of Conventional and Radiomic Features between (18)F-FBPA PET/CT and PET/MR
title_sort comparison of conventional and radiomic features between (18)f-fbpa pet/ct and pet/mr
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8615400/
https://www.ncbi.nlm.nih.gov/pubmed/34827657
http://dx.doi.org/10.3390/biom11111659
work_keys_str_mv AT liaochienyi comparisonofconventionalandradiomicfeaturesbetween18ffbpapetctandpetmr
AT jenjunhsuang comparisonofconventionalandradiomicfeaturesbetween18ffbpapetctandpetmr
AT chenyiwei comparisonofconventionalandradiomicfeaturesbetween18ffbpapetctandpetmr
AT lichienying comparisonofconventionalandradiomicfeaturesbetween18ffbpapetctandpetmr
AT wanglingwei comparisonofconventionalandradiomicfeaturesbetween18ffbpapetctandpetmr
AT liurenshyan comparisonofconventionalandradiomicfeaturesbetween18ffbpapetctandpetmr
AT huangwensheng comparisonofconventionalandradiomicfeaturesbetween18ffbpapetctandpetmr
AT luchiafeng comparisonofconventionalandradiomicfeaturesbetween18ffbpapetctandpetmr