Cargando…

Assessment of Brain Functional Activity Using a Miniaturized Head-Mounted Scanning Photoacoustic Imaging System in Awake and Freely Moving Rats

Understanding the relationship between brain function and natural behavior remains a significant challenge in neuroscience because there are very few convincing imaging/recording tools available for the evaluation of awake and freely moving animals. Here, we employed a miniaturized head-mounted scan...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yuhling, Chu, Tsung-Sheng, Lin, Yan-Ren, Tsao, Chia-Hui, Tsai, Chia-Hua, Ger, Tzong-Rong, Chen, Li-Tzong, Chang, Wun-Shaing Wayne, Liao, Lun-De
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8615926/
https://www.ncbi.nlm.nih.gov/pubmed/34821645
http://dx.doi.org/10.3390/bios11110429
_version_ 1784604223667699712
author Wang, Yuhling
Chu, Tsung-Sheng
Lin, Yan-Ren
Tsao, Chia-Hui
Tsai, Chia-Hua
Ger, Tzong-Rong
Chen, Li-Tzong
Chang, Wun-Shaing Wayne
Liao, Lun-De
author_facet Wang, Yuhling
Chu, Tsung-Sheng
Lin, Yan-Ren
Tsao, Chia-Hui
Tsai, Chia-Hua
Ger, Tzong-Rong
Chen, Li-Tzong
Chang, Wun-Shaing Wayne
Liao, Lun-De
author_sort Wang, Yuhling
collection PubMed
description Understanding the relationship between brain function and natural behavior remains a significant challenge in neuroscience because there are very few convincing imaging/recording tools available for the evaluation of awake and freely moving animals. Here, we employed a miniaturized head-mounted scanning photoacoustic imaging (hmPAI) system to image real-time cortical dynamics. A compact photoacoustic (PA) probe based on four in-house optical fiber pads and a single custom-made 48-MHz focused ultrasound transducer was designed to enable focused dark-field PA imaging, and miniature linear motors were included to enable two-dimensional (2D) scanning. The total dimensions and weight of the proposed hmPAI system are only approximately 50 × 64 × 48 mm and 58.7 g (excluding cables). Our ex vivo phantom experimental tests revealed that a spatial resolution of approximately 0.225 mm could be achieved at a depth of 9 mm. Our in vivo results further revealed that the diameters of cortical vessels draining into the superior sagittal sinus (SSS) could be clearly imaged and continuously observed in both anesthetized rats and awake, freely moving rats. Statistical analysis showed that the full width at half maximum (FWHM) of the PA A-line signals (relative to the blood vessel diameter) was significantly increased in the selected SSS-drained cortical vessels of awake rats (0.58 ± 0.17 mm) compared with those of anesthetized rats (0.31 ± 0.09 mm) (p < 0.01, paired t-test). In addition, the number of pixels in PA B-scan images (relative to the cerebral blood volume (CBV)) was also significantly increased in the selected SSS-drained blood vessels of awake rats (107.66 ± 23.02 pixels) compared with those of anesthetized rats (81.99 ± 21.52 pixels) (p < 0.01, paired t-test). This outcome may result from a more active brain in awake rats than in anesthetized rats, which caused cerebral blood vessels to transport more blood to meet the increased nutrient demand of the tissue, resulting in an obvious increase in blood vessel volume. This hmPAI system was further validated for utility in the brains of awake and freely moving rats, showing that their natural behavior was unimpaired during vascular imaging, thereby providing novel opportunities for studies of behavior, cognition, and preclinical models of brain diseases.
format Online
Article
Text
id pubmed-8615926
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-86159262021-11-26 Assessment of Brain Functional Activity Using a Miniaturized Head-Mounted Scanning Photoacoustic Imaging System in Awake and Freely Moving Rats Wang, Yuhling Chu, Tsung-Sheng Lin, Yan-Ren Tsao, Chia-Hui Tsai, Chia-Hua Ger, Tzong-Rong Chen, Li-Tzong Chang, Wun-Shaing Wayne Liao, Lun-De Biosensors (Basel) Article Understanding the relationship between brain function and natural behavior remains a significant challenge in neuroscience because there are very few convincing imaging/recording tools available for the evaluation of awake and freely moving animals. Here, we employed a miniaturized head-mounted scanning photoacoustic imaging (hmPAI) system to image real-time cortical dynamics. A compact photoacoustic (PA) probe based on four in-house optical fiber pads and a single custom-made 48-MHz focused ultrasound transducer was designed to enable focused dark-field PA imaging, and miniature linear motors were included to enable two-dimensional (2D) scanning. The total dimensions and weight of the proposed hmPAI system are only approximately 50 × 64 × 48 mm and 58.7 g (excluding cables). Our ex vivo phantom experimental tests revealed that a spatial resolution of approximately 0.225 mm could be achieved at a depth of 9 mm. Our in vivo results further revealed that the diameters of cortical vessels draining into the superior sagittal sinus (SSS) could be clearly imaged and continuously observed in both anesthetized rats and awake, freely moving rats. Statistical analysis showed that the full width at half maximum (FWHM) of the PA A-line signals (relative to the blood vessel diameter) was significantly increased in the selected SSS-drained cortical vessels of awake rats (0.58 ± 0.17 mm) compared with those of anesthetized rats (0.31 ± 0.09 mm) (p < 0.01, paired t-test). In addition, the number of pixels in PA B-scan images (relative to the cerebral blood volume (CBV)) was also significantly increased in the selected SSS-drained blood vessels of awake rats (107.66 ± 23.02 pixels) compared with those of anesthetized rats (81.99 ± 21.52 pixels) (p < 0.01, paired t-test). This outcome may result from a more active brain in awake rats than in anesthetized rats, which caused cerebral blood vessels to transport more blood to meet the increased nutrient demand of the tissue, resulting in an obvious increase in blood vessel volume. This hmPAI system was further validated for utility in the brains of awake and freely moving rats, showing that their natural behavior was unimpaired during vascular imaging, thereby providing novel opportunities for studies of behavior, cognition, and preclinical models of brain diseases. MDPI 2021-10-30 /pmc/articles/PMC8615926/ /pubmed/34821645 http://dx.doi.org/10.3390/bios11110429 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Yuhling
Chu, Tsung-Sheng
Lin, Yan-Ren
Tsao, Chia-Hui
Tsai, Chia-Hua
Ger, Tzong-Rong
Chen, Li-Tzong
Chang, Wun-Shaing Wayne
Liao, Lun-De
Assessment of Brain Functional Activity Using a Miniaturized Head-Mounted Scanning Photoacoustic Imaging System in Awake and Freely Moving Rats
title Assessment of Brain Functional Activity Using a Miniaturized Head-Mounted Scanning Photoacoustic Imaging System in Awake and Freely Moving Rats
title_full Assessment of Brain Functional Activity Using a Miniaturized Head-Mounted Scanning Photoacoustic Imaging System in Awake and Freely Moving Rats
title_fullStr Assessment of Brain Functional Activity Using a Miniaturized Head-Mounted Scanning Photoacoustic Imaging System in Awake and Freely Moving Rats
title_full_unstemmed Assessment of Brain Functional Activity Using a Miniaturized Head-Mounted Scanning Photoacoustic Imaging System in Awake and Freely Moving Rats
title_short Assessment of Brain Functional Activity Using a Miniaturized Head-Mounted Scanning Photoacoustic Imaging System in Awake and Freely Moving Rats
title_sort assessment of brain functional activity using a miniaturized head-mounted scanning photoacoustic imaging system in awake and freely moving rats
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8615926/
https://www.ncbi.nlm.nih.gov/pubmed/34821645
http://dx.doi.org/10.3390/bios11110429
work_keys_str_mv AT wangyuhling assessmentofbrainfunctionalactivityusingaminiaturizedheadmountedscanningphotoacousticimagingsysteminawakeandfreelymovingrats
AT chutsungsheng assessmentofbrainfunctionalactivityusingaminiaturizedheadmountedscanningphotoacousticimagingsysteminawakeandfreelymovingrats
AT linyanren assessmentofbrainfunctionalactivityusingaminiaturizedheadmountedscanningphotoacousticimagingsysteminawakeandfreelymovingrats
AT tsaochiahui assessmentofbrainfunctionalactivityusingaminiaturizedheadmountedscanningphotoacousticimagingsysteminawakeandfreelymovingrats
AT tsaichiahua assessmentofbrainfunctionalactivityusingaminiaturizedheadmountedscanningphotoacousticimagingsysteminawakeandfreelymovingrats
AT gertzongrong assessmentofbrainfunctionalactivityusingaminiaturizedheadmountedscanningphotoacousticimagingsysteminawakeandfreelymovingrats
AT chenlitzong assessmentofbrainfunctionalactivityusingaminiaturizedheadmountedscanningphotoacousticimagingsysteminawakeandfreelymovingrats
AT changwunshaingwayne assessmentofbrainfunctionalactivityusingaminiaturizedheadmountedscanningphotoacousticimagingsysteminawakeandfreelymovingrats
AT liaolunde assessmentofbrainfunctionalactivityusingaminiaturizedheadmountedscanningphotoacousticimagingsysteminawakeandfreelymovingrats